Back to products
LC1DT20B7 | TeSys 4P CONTACTOR 20A AC-1 230VAC COIL - Schneider Electric
LC1DT20B7 | TeSys 4P CONTACTOR 20A AC-1 230VAC COIL - Schneider Electric Original price was: ₹6,940.00.Current price is: ₹3,053.60. Excl. GST

LC1D50U7 | 3P OLD CONT 25KW 1NO 1NC 240VAC COIL – Schneider Electric

SKU: LC1D50U7

Original price was: ₹35,260.00.Current price is: ₹15,514.40. Excl. GST

In stock

In stock

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: LC1D50U7

Same-day dispatch · GST invoice available

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1D50U7 | 3P OLD CONT 25KW 1NO 1NC 240VAC COIL? This genuine Schneider Electric electrical component from the TeSys range is built for industrial, commercial, and infrastructure applications, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 50 A, Power circuit: <= 690 V AC 25...400 Hz, 3P. Order part number LC1D50U7 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1D50U7
CategoryElectrical Component
Main
RangeTeSys
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Motor control
Utilisation categoryAC-3
AC-4
AC-2
AC-1
AC-3e
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
[Ie] rated operational current50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage240 V AC 50/60 Hz
Complementary
Motor power kW22 kW at 380…400 V AC 50 Hz (AC-3)
25 kW at 415 V AC 50 Hz (AC-3)
30 kW at 440 V AC 50 Hz (AC-3)
30 kW at 500 V AC 50 Hz (AC-3)
33 kW at 660…690 V AC 50 Hz (AC-3)
15 kW at 220…230 V AC 50 Hz (AC-3)
11 kW at 400 V AC 50 Hz (AC-4)
30 kW at 1000 V AC 50 Hz (AC-3)
22 kW at 380…400 V AC 50 Hz (AC-3e)
25 kW at 415 V AC 50 Hz (AC-3e)
30 kW at 440 V AC 50 Hz (AC-3e)
30 kW at 500 V AC 50 Hz (AC-3e)
33 kW at 660…690 V AC 50 Hz (AC-3e)
15 kW at 220…230 V AC 50 Hz (AC-3e)
30 kW at 1000 V AC 50 Hz (AC-3e)
Motor power hp3 hp at 115 V AC 60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
15 hp at 200/208 V AC 60 Hz for 3 phases motors
15 hp at 230/240 V AC 60 Hz for 3 phases motors
40 hp at 460/480 V AC 60 Hz for 3 phases motors
40 hp at 575/600 V AC 60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for control circuit
80 A (at 60 °C) for power circuit
Irms rated making capacity900 A at 440 V for power circuit conforming to IEC 60947
140 A AC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity900 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating10 A gG for control circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
100 A gG at <= 690 V coordination type 2 for power circuit
Power dissipation per pole3.7 W AC-3
9.6 W AC-1
3.7 W AC-3e
[Ui] rated insulation voltageControl circuit: 600 V CSA certified
Control circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-1
Overvoltage categoryIII
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA140 VA cos phi 0.75 (at 20 °C)
160 VA cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation4…5 W at 50/60 Hz for control circuit
Operating time4…19 ms opening
12…26 ms closing
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsControl circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: rigid
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: rigid
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: rigid
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end
Tightening torqueControl circuit: 1.7 N.m – on screw clamp terminal – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver Philips No 2
Power circuit: 5 N.m – on screw terminal – with screwdriver flat Ø 6 to Ø 8 mm
Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts
Mounting supportRail
Plate
Environment
StandardsIEC 60947-5-1
EN 60947-4-1
UL 60947-4-1
CSA C22.2 No 14
EN 60947-5-1
IEC 60947-4-1
Product certificationsBV
CCC
LROS (Lloyds register of shipping)
DNV
GOST
GL
RINA
UL
CSA
UKCA
IP degree of protectionIP2X conforming to IEC 60529
IP2X conforming to VDE 0106
Climatic withstandconforming to IACS E10 exposure to damp heat
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessShocks contactor opened (10 Gn for 11 ms)
Shocks contactor closed (15 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Height127 mm
Width75 mm
Depth119 mm
Product weight1.4 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height12.500 cm
Package 1 Width13.200 cm
Package 1 Length8.200 cm
Package 1 Weight1.431 kg
Unit Type of Package 2S02
Number of Units in Package 25
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.561 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 240V AC coil or control supply voltage — directly compatible with standard panel control circuits.
  • Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LA9D5017LA4DA1ULA4DFBLA4DT2ULA4DWBLA4DT0ULA4DT4ULADN22LADN11LADN20LAD8N11LADT2LADN40LADN31LADN02LADT0LAD8N20LADS2LADR2LADR0LADN04LADN13LADR4LADT4LAD8N02LX1D6U7

❓ Frequently Asked Questions

Q: The LC1D50U7 has a coil voltage of 240V AC — what control supply is needed?

A: This Schneider Electric device requires a 240V AC control supply connected to the coil terminals (A1 and A2). For AC coils, ensure the control circuit voltage is stable — voltage drops below 85% of rated coil voltage can cause chatter and coil overheating. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.