LV432876 | 3P3T MICROLOGIC 2.3 630A NSX630F – Schneider Electric
₹97,060.00 Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LV432597 | direct rotary handle, Compact NSX 400/630, PowerPact Multistandard L, EasyPact CVS 400/630, black standard handle, IP40 – Schneider Electric
LV429390 | MX 24V DC SHUNT RELEASE. – Schneider Electric
LV432641 | motor mechanism, MT 400-630, Compact NSX400/630, PowerPact Multistandard L, 220 to 240 VAC 50/60 Hz, 208 to 277 VAC 60 Hz – Schneider Electric
LV429387 | MX shunt trip release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 220 to 240 VAC 50/60 Hz, 208 to 277 VAC 60 Hz – Schneider Electric
LV429410 | MN undervoltage release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 24 VDC – Schneider Electric
LV429408 | MN 380-415V50/60HZ 440-480V60HZ UVR – Schneider Electric
29450 | standard auxiliary contact, circuit breaker status OF-SD-SDE-SDV, 1 single contact – Schneider Electric
LV432642 | 380 415V AC 50 60HZ MT400 630 – Schneider Electric
LV429388 | MX shunt trip release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 380 to 415 VAC 50/60 Hz, 440 to 480 VAC 60 Hz – Schneider Electric
LV429407 | MN undervoltage release, Compact NSX, PowerPact Multistandard, EasyPact CVS, rated voltage 220 to 240 VAC 50/60 Hz, 208 to 277 VAC 60 Hz – Schneider Electric
The Schneider Electric LV432876 is a mccb from the ComPact range, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 630 A at 40 °C, 690 V AC 50/60 Hz, 3P. Buy the LV432876 | 3P3T MICROLOGIC 2.3 630A NSX630F online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LV432876 |
| Category | MCCB |
| Main | |
| Range | ComPact |
| Product name | ComPact NSX |
| Range of product | ComPact NSX400…630 |
| Device short name | NSX630F |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Number of poles | 3P |
| Protected poles description | 3t |
| [In] rated current | 630 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 240 V AC 50/60 Hz conforming to UL 508 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 480 V AC 50/60 Hz conforming to UL 508 20 kA at 600 V AC 50/60 Hz conforming to UL 508 20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | MicroLogic 2.3 |
| Trip unit technology | Electronic |
| Trip unit protection functions | LSoI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| Complementary | |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 15000 cycles |
| Electrical durability | 2000 cycles at 690 V In 6000 cycles at 690 V In/2 4000 cycles at 440 V In 8000 cycles at 440 V In/2 |
| Mounting support | Backplate |
| Upside connection | Front |
| Downside connection | Front |
| Connection pitch | 45 mm |
| Protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection |
| Trip unit rating | 630 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 250…630 A |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 16 s at 6 x Ir |
| Thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5…10 x Ir |
| Short-time protection delay adjustment type tsd | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 6900 A |
| Earth-leakage protection | Without |
| Zone selective interlocking ZSI | Without |
| Number of slots for electrical auxiliaries | 6 slot(s) |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Width (W) | 140 mm |
| Height (H) | 255 mm |
| Depth (D) | 110 mm |
| Product weight | 6.2 kg |
| Environment | |
| Standards | EN/IEC 60947 |
| Product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0…2000 m without derating 2000 m…5000 m with derating |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 29.0 cm |
| Package 1 Width | 15.0 cm |
| Package 1 Length | 15.6 cm |
| Package 1 Weight | 5.69 kg |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 3 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 40.0 cm |
| Package 2 Length | 60.0 cm |
| Package 2 Weight | 17.884 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 630 A frame rating — handles the full rated current continuously; designed for feeder and sub-distribution protection where fault levels exceed MCB capability.
- Performance level F — breaking capacity 36 kA (standard breaking capacity, suitable for commercial and light industrial boards).
- Micrologic electronic trip unit — In = 630 A; adjustable Ir (overload), Isd (short-time delay), and Im (instantaneous) for selective protection coordination.
- CompacT NSX form factor — 70mm wide per pole; designed for high-density LV switchboards with up to 3 units per standard 250mm busbar bay.
- Rotary handle with padlocking points — LOTO compliant; handle locks in OFF position with up to 3 padlocks, preventing accidental energisation during maintenance.
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What load can the LV432876 protect at its rated 630 A?
A: The LV432876 is rated to carry and protect circuits up to 630 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 630 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What trip unit type does the LV432876 use — thermal-magnetic or electronic?
A: The LV432876 uses a MicroLogic electronic trip unit, offering adjustable protection functions: long-time overload (Ir), short-time (Isd), and instantaneous (Ii) settings, with optional earth fault protection. Electronic trip units provide superior accuracy over thermal-magnetic units.
Q: Is the LV432876 suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.
Q: Can the LV432876 be motorised for remote switching and automation?
A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: Which Schneider Electric accessories are compatible with the LV432876?
A: The Schneider Electric LV432876 series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the LV432876.