TM221CE24U | CONTROLLER M221-24IO TR.NPN ETHERNET - Schneider Electric
TM221CE24U | CONTROLLER M221-24IO TR.NPN ETHERNET - Schneider Electric Original price was: ₹62,601.00.Current price is: ₹31,926.51. Excl. GST
Back to products
TM3XHSC202G | Module TM3 Expert 2 HSC, Spring - Schneider Electric
TM3XHSC202G | Module TM3 Expert 2 HSC, Spring - Schneider Electric Original price was: ₹54,323.00.Current price is: ₹19,556.28. Excl. GST

TM3TM3 | MODULE TM3-2 TEMP INPUT 1 ANALOG OUT. – Schneider Electric

SKU: TM3TM3

Original price was: ₹54,597.00.Current price is: ₹19,654.92. Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: TM3TM3

Same-day dispatch · GST invoice available

17 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Schneider Electric TM3TM3 is a plc i/o module from the Modicon TM3 range, engineered for industrial, commercial, and infrastructure applications in demanding Indian and international installations. Key ratings include IP20. Buy the TM3TM3 | MODULE TM3-2 TEMP INPUT 1 ANALOG OUT. online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUTM3TM3
CategoryPLC I/O Module
Main
Range of productModicon TM3
Product or component typeInput/output analog module
Range compatibilityModicon M221
Modicon M241
Modicon M251
Modicon M262
Analogue input number2
Analogue output number1
Complementary
Analogue input typeCurrent 4…20 mA
Current 0…20 mA
Voltage 0…10 V
Voltage – 10…10 V
Thermocouple – 200…1000 °C thermocouple J
Thermocouple – 200…1300 °C thermocouple K
Thermocouple 0…1760 °C thermocouple R
Thermocouple 0…1760 °C thermocouple S
Thermocouple 0…1820 °C thermocouple B
Thermocouple – 200…400 °C thermocouple T
Thermocouple – 200…1300 °C thermocouple N
Thermocouple – 200…800 °C thermocouple E
Thermocouple 0…2315 °C thermocouple C
Temperature probe – 60…180 °C Ni 100/Ni 1000
Temperature probe – 200…850 °C Pt 100
Temperature probe – 200…600 °C Pt 1000
Analogue input resolution16 bits
15 bits + sign
Permissible continuous overload13 V, analogue input type: voltage
40 mA, analogue input type: current
Stabilisation time1 ms
Input impedance<= 50 Ohm
>= 1 MOhm
Sampling duration10 ms
Analogue output typeCurrent: 4…20 mA
Current: 0…20 mA
Voltage: 0…10 V
Voltage: – 10…10 V
Conversion time100 ms + 100 ms per channel + 1 controller cycle time for analogue input thermocouple
Absolute accuracy error+/- 6 °C at 25 °C for thermocouple R, S 0…200 °C
+/- 0.4 % of full scale at 25 °C for thermocouple K – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple J – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple E – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple T – 200…0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple N – 200…0 °C
+/- 0.1 % of full scale at 25 °C for analogue input voltage/current
+/- 0.1 % of full scale at 25 °C for thermocouple C 0…2315 °C
+/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe
+/- 0.1 % of full scale at 25 °C for thermocouple R, S 200…1760 °C
+/- 0.1 % of full scale at 25 °C for thermocouple B 300…1820 °C
+/- 0.1 % of full scale at 25 °C for thermocouple K 0…1300 °C
+/- 0.1 % of full scale at 25 °C for thermocouple J 0…1000 °C
+/- 0.1 % of full scale at 25 °C for thermocouple E 0…800 °C
+/- 0.1 % of full scale at 25 °C for thermocouple T 0…400 °C
+/- 0.1 % of full scale at 25 °C for thermocouple N 0…1300 °C
+/- 0.1 % of full scale at 25 °C for analogue output voltage/current
Repeat accuracy+/-0.5 %FS for input
Output ripple20 mV
Cross talk<= 1 LSB
Type of cableTwisted shielded pairs cable <30 m for input/output circuit
Electrical connection11 x 2.5 mm² removable screw terminal block with pitch 5.08 mm adjustment for inputs, outputs and supply
LSB value0.15 mV, 0…10 V
0.30 mV, – 10…10 V
0.30 µA, 0…20 mA
0.244 µA, 4…20 mA
0.1 °C
2.44 mV, 0…10 V
4.88 mV, – 10…10 V
4.88 µA, 0…20 mA
3.91 µA, 4…20 mA
InsulationBetween input and supply at 1500 V AC
Between input and internal logic at 500 V AC
Between output and supply at 1500 V AC
Between output and internal logic at 500 V AC
Immunity to microbreaks10 ms
Load impedance ohmic1 kOhm voltage
300 Ohm current
load typeResistive
Temperature drift+/- 0.006 %FS/°C
Non-linearity+/- 0.01 %FS, analogue output type: analog output
+/- 0.1 %FS, analogue input type: analog input
Typical current consumption55 mA at 24 V DC no load
55 mA at 5 V DC no load
60 mA at 5 V DC full load
80 mA at 24 V DC full load
Local signalling1 LED green for PWR
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height90 mm
Width23.6 mm
Depth70 mm
Product weight0.115 kg
Environment
IP degree of protectionIP20
MarkingCE
Product certificationsCE
UKCA
RCM
EAC
CULus
CULus HazLoc
StandardsIEC 61131-2
Electromagnetic emissionRadiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to IEC 55011
Ambient air temperature for operation-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 % without condensation
Operating altitude0…2000 m
Pollution degree2
Vibration resistance3.5 mm (f = 5…8.4 Hz) on DIN rail
3 gn (f = 8.4…150 Hz) on DIN rail
Shock resistance15 gn for 11 ms
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.611 cm
Package 1 Width10.688 cm
Package 1 Length12.753 cm
Package 1 Weight220.0 g
Unit Type of Package 2S04
Number of Units in Package 242
Package 2 Height30 cm
Package 2 Width40 cm
Package 2 Length60 cm
Package 2 Weight10.421 kg
Unit Type of Package 3P12
Number of Units in Package 3504
Package 3 Height105 cm
Package 3 Width120 cm
Package 3 Length80 cm
Package 3 Weight130 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

TMAM2

Customer Reviews