RM35JA32MR | Current relay OC/UC 150mA 15A 3.5VA2CO – Schneider Electric
₹8,729.00 Original price was: ₹8,729.00.₹4,015.34Current price is: ₹4,015.34. Excl. GST
Dispatch By : 1 Weeks
Dispatch By : 1 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
RM17TE00 | PH ROT:FAILURE 208-480VAC ASYMM UV/OV – Schneider Electric
Sourced through authorised channels, the Schneider Electric RM35JA32MR relay from the Harmony Control Relays range delivers dependable performance for motor control and switching. Key ratings include 15 A, IP20 (terminals). myelectric.in stocks the RM35JA32MR | Current relay OC/UC 150mA 15A 3.5VA2CO for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | RM35JA32MR |
| Category | Relay |
| Main | |
| Range of product | Harmony Control Relays |
| Relay type | Current control relay |
| Product or component type | Current control relay |
| Relay name | RM35JA |
| Relay monitored parameters | Overcurrent or undercurrent in window mode Overcurrent or undercurrent detection |
| Time delay type | Adjustable 0.1…30 s, +/- 10 % of the full scale value Tt- time delay upon fault |
| Switching capacity in VA | 2000 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 8 A AC |
| Maximum power consumption in VA | 3.5 VA |
| Measurement range | 150 mA…15 A AC/DC |
| Utilisation category | AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1 |
| Contacts type and composition | 2 C/O |
| Complementary | |
| Reset time | 1500 ms at maximum voltage |
| Maximum switching voltage | 250 V AC |
| Supply voltage limits | 20.4…264 V AC/DC |
| operating voltage tolerance | – 15 % + 10 % Un |
| Maximum power consumption in W | 1.5 W DC |
| Resistance across terminals | 0.005 Ohm at E3-M terminals 0.015 Ohm at E2-M terminals 0.05 Ohm at E1-M terminals |
| Output contacts | 2 C/O |
| nominal output current | 8 A |
| Maximum measuring cycle | 100 ms measurement cycle as true rms value |
| Internal input resistance | 0.015 Ohm 0.005 Ohm 0.05 Ohm |
| Setting accuracy of the switching threshold | +/- 10 % of the full scale |
| Switching threshold drift | <= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range |
| Setting accuracy of time delay | 10 P |
| Time delay drift | <= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range |
| Hysteresis | 5…50 % adjustable of threshold setting 3 % fixed of full scale for window mode |
| delay at power up | 0.3 s |
| Repeat accuracy | +/- 0.5 % for input and measurement circuit +/- 2 % for time delay |
| Measurement error | < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation |
| Response time | <= 500 ms (on crossing the threshold) |
| Threshold setting | 10…100 % |
| Overvoltage category | III conforming to IEC 60664-1 III conforming to UL 508 |
| Insulation resistance | > 100 MOhm at 500 V DC conforming to IEC 60255-27 |
| Insulation | Between supply and measurement |
| Connections – terminals | Screw terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end Screw terminals, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) solid without cable end Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Polycarbonate |
| Local signalling | LED (yellow) for relay ON LED (green) for power ON |
| Mounting support | 35 mm DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 10000000 cycles |
| [Us] rated supply voltage | 24…240 V AC/DC 50/60 Hz, non self-powered |
| Safety reliability data | MTTFd = 296.8 years B10d = 270000 |
| Contacts material | Cadmium free |
| Width | 35 mm |
| Control type | With test button |
| Product weight | 0.12 kg |
| Environment | |
| Immunity to microbreaks | 50 ms |
| Electromagnetic compatibility | Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 Immunity for industrial environments conforming to IEC 61000-6-2 Emission standard for industrial environments conforming to IEC 61000-6-4 Electrostatic discharge – test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge – test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test – test level: 10 V/m level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test – test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4 Surge immunity test – test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Surge immunity test – test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Conducted and radiated emissions class B group 1 conforming to CISPR 11 Conducted and radiated emissions class B conforming to CISPR 22 Emission standard for residential, commercial and light-industrial environments (except radiated emission) conforming to IEC 61000-6-3 |
| Standards | IEC 60255-1 |
| Product certifications | CE GL CCC EAC RCM UL CSA |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -20…50 °C at 60 Hz -20…60 °C at 50 Hz |
| Environmental characteristic | 3K3 C |
| Relative humidity | 93…97 % at 25…55 °C conforming to IEC 60068-2-30 |
| Vibration resistance | 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 IP30 (housing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 3 conforming to UL 508 |
| Dielectric test voltage | 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.800 cm |
| Package 1 Width | 4.500 cm |
| Package 1 Length | 9.500 cm |
| Package 1 Weight | 140.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 32 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.743 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 512 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 84.388 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Manufactured to IEC 60947-5-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What is the significance of the 15 A rating on the RM35JA32MR?
A: The 15 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.
Q: Why is the 150 mA sensitivity specified on the RM35JA32MR and when should you choose a different rating?
A: 150 mA is the residual current at which the RM35JA32MR will trip within 300ms. A 30mA sensitivity provides additional shock protection (mandatory for socket circuits per IS 732). 100mA is used for fire protection (no shock protection). 300mA protects feeders without nuisance tripping. Choose based on the circuit’s risk profile — never use >30mA for socket outlet circuits in wet or high-risk locations.
Q: Can the RM35JA32MR relay be mounted on a DIN rail socket for easy replacement?
A: This Schneider Electric relay typically requires direct panel or DIN rail wiring. For applications requiring frequent relay replacement, consider the plug-in relay variant of this series with a matching socket base.
Q: How do I test the RM35JA32MR relay in the field without a signal source?
A: Most Schneider Electric relays can be manually forced using the test button (if fitted) — this mechanically closes the relay contacts without energising the coil, allowing functional testing of the controlled circuit. For coil testing, use a multimeter to measure coil resistance (typically 500–2000Ω for AC coils at rated voltage) and compare with datasheet values.