XB5AA42 | PB plastic red flush unmark 1NC - Schneider Electric
XB5AA42 | PB plastic red flush unmark 1NC - Schneider Electric Original price was: ₹784.00.Current price is: ₹493.92. Excl. GST
Back to products
ZB4BW353 | Head ill PB metal orange flush lens LED - Schneider Electric
ZB4BW353 | Head ill PB metal orange flush lens LED - Schneider Electric Original price was: ₹767.00.Current price is: ₹483.21. Excl. GST

RSB2A080FD | Interface relay 8A 2CO 110V DC – Schneider Electric

SKU: RSB2A080FD

Original price was: ₹822.00.Current price is: ₹378.12. Excl. GST

Dispatch By : 6 Weeks

Dispatch By : 6 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: RSB2A080FD

Same-day dispatch · GST invoice available

15 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Sourced through authorised channels, the Schneider Electric RSB2A080FD relay from the Harmony Electromechanical Relays range delivers dependable performance for motor control and switching. Key ratings include 4 A, 77…165 V DC, IP40. myelectric.in stocks the RSB2A080FD | Interface relay 8A 2CO 110V DC for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKURSB2A080FD
CategoryRelay
Main
Range of productHarmony Electromechanical Relays
Series nameRSB series
Product or component typePlug-in relay
Relay typeInterface relay
Contacts type and composition2 C/O
status LEDWithout
[Uc] control circuit voltage110 V DC
Control typeWithout lockable test button
[Ithe] conventional enclosed thermal current8 A at -40…40 °C
Complementary
Average resistance30250 Ohm network: AC at 20 °C +/- 10 %
[Ue] rated operational voltage77…165 V DC
[Uimp] rated impulse withstand voltage3.6 kV conforming to IEC 61000-4-5
[Ie] rated operational current4 A (AC-1/DC-1) NC conforming to IEC
8 A (AC-1/DC-1) NO conforming to IEC
[Ui] rated insulation voltage400 V conforming to IEC 60947
Maximum switching voltage300 V DC conforming to IEC
Drop-out voltage threshold>= 0.1 Uc DC
Load current8 A at 250 V AC
8 A at 28 V DC
minimum switching current10 mA
Maximum switching capacity2000 VA/224 W
minimum switching voltage12 V
Minimum switching capacity120 mW at 10 mA, 12 V
Operating time20 ms operating
20 ms reset
Mechanical durability30000000 cycles
Electrical durability100000 cycles, 8 A at 250 V, AC-1 NO
100000 cycles, 4 A at 250 V, AC-1 NC
Safety reliability dataB10d = 100000
Operating rate<= 600 cycles/hour under load
<= 18000 cycles/hour no-load
Average coil consumption0.45 W DC
Removable legendWithout
Protection categoryRT I
Operating positionAny position
Test levelsLevel A group mounting
Device presentationComplete product
Sale per indivisible quantity10
Contacts materialSilver alloy (AgNi)
Shape of pinFlat (PCB type)
Product weight0.014 kg
Compatibility codeRSB
Environment
Dielectric strength1000 V AC between contacts
2500 V AC between poles
5000 V AC between coil and contact
Vibration resistance+/- 1 mm (f= 10…55 Hz) conforming to IEC 60068-2-6
IP degree of protectionIP40 conforming to IEC 60529
Ambient air temperature for operation-40…85 °C (DC)
StandardsIEC 61810-1
CSA C22.2 No 14
UL 508
Product certificationsUL
CSA
EAC
MarkingCE
Ambient air temperature for storage-40…85 °C
Shock resistance10 gn (duration = 11 ms) for not operating conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height1.700 cm
Package 1 Width2.000 cm
Package 1 Length3.000 cm
Package 1 Weight13.000 g
Unit Type of Package 2BB1
Number of Units in Package 210
Package 2 Height1.700 cm
Package 2 Width2.500 cm
Package 2 Length31.100 cm
Package 2 Weight149.000 g
Unit Type of Package 3S01
Number of Units in Package 3350
Package 3 Height15.000 cm
Package 3 Width15.000 cm
Package 3 Length40.000 cm
Package 3 Weight5.850 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 2 CO (Changeover) contact arrangement — all contacts independently switchable up to the contact voltage rating.
  • Manufactured to IEC 60947-5-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

RSZE1S48M

❓ Frequently Asked Questions

Q: What is the significance of the 8 A rating on the RSB2A080FD?

A: The 8 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.

Q: What does the 2 CO (Changeover) contact configuration on the RSB2A080FD mean?

A: CO (Change Over) contacts switch between two circuits — the common terminal connects to either NO or NC depending on the device state. Used for dual-purpose indication or reversing circuits.

Q: How do I test the RSB2A080FD relay in the field without a signal source?

A: Most Schneider Electric relays can be manually forced using the test button (if fitted) — this mechanically closes the relay contacts without energising the coil, allowing functional testing of the controlled circuit. For coil testing, use a multimeter to measure coil resistance (typically 500–2000Ω for AC coils at rated voltage) and compare with datasheet values.

Q: Can the RSB2A080FD relay be mounted on a DIN rail socket for easy replacement?

A: This Schneider Electric relay typically requires direct panel or DIN rail wiring. For applications requiring frequent relay replacement, consider the plug-in relay variant of this series with a matching socket base.

Customer Reviews