A9KR12225 Acti 9K RCCB 2P 25A 100 mA AC-type Schneider Electric pb110018 web
A9KR12225 | Acti 9K RCCB 2P 25A 100 mA AC-type - Schneider Electric Original price was: ₹3,696.00.Current price is: ₹1,995.84. Excl. GST
Back to products
A9L08600 iPRD8 modular surge arrester 3P N 350V Schneider Electric pb110281 1500x1500
A9L08600 | iPRD8 modular surge arrester - 3P + N - 350V - Schneider Electric Original price was: ₹25,432.00.Current price is: ₹15,767.84. Excl. GST

A9KR14463 | Acti 9K RCCB 4P 63A 300 mA AC-type – Schneider Electric

SKU: A9KR14463

Original price was: ₹5,600.00.Current price is: ₹3,024.00. Excl. GST

Out of stock

Out of stock

15 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

📋 Technical Specifications

ParameterValue
BrandSchneider Electric
Part Number / SKUA9KR14463
CategoryRCCB
Current Rating63 A
Poles4 Poles
Sensitivity300 mA
StandardIEC 61008 / IS 12640-1
CertificationsBIS certified, CE marked, RoHS compliant

⚡ Key Features

  • 300 mA sensitivity — coarse sensitivity for fire protection on large circuits — must be backed by a 30mA RCCB at the point of use for personnel protection.
  • 63 A rated load current — the RCCB carries this full circuit current continuously while monitoring the live-neutral balance for any earth leakage.
  • 4 Poles — for three-phase four-wire (TN-S/TT) installations; all four conductors pass through the toroidal CT for complete leakage detection.
  • Earth-leakage protection only — no overload or short-circuit protection; install in series with an appropriately rated MCB for full circuit protection.
  • Mandatory test button — simulate a leakage fault to verify the trip mechanism without live fault conditions; test monthly per IS 12640 recommendation.
  • Type AC — designed for purely sinusoidal AC residual currents on standard residential and commercial circuits.
  • Manufactured to IEC 61008 / IS 12640-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.

❓ Frequently Asked Questions

Q: What is the significance of the 63 A rating on the A9KR14463?

A: The 63 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.

Q: Why is the 300 mA sensitivity specified on the A9KR14463 and when should you choose a different rating?

A: 300 mA is the residual current at which the A9KR14463 will trip within 300ms. A 30mA sensitivity provides additional shock protection (mandatory for socket circuits per IS 732). 100mA is used for fire protection (no shock protection). 300mA protects feeders without nuisance tripping. Choose based on the circuit’s risk profile — never use >30mA for socket outlet circuits in wet or high-risk locations.

Q: How many downstream circuits can be protected under the A9KR14463 without nuisance tripping?

A: Downstream MCBs or RCBOs can be connected below the A9KR14463, but the total standing leakage current of all connected circuits must not exceed 30–50% of the RCCB’s rated sensitivity — typically 9–15mA for a 30mA device. Each appliance with a filter (computers, VFDs, LED drivers) contributes 0.5–3mA of standing leakage, so limit the count of such loads per RCCB to prevent cumulative leakage causing nuisance tripping.

Q: Will the A9KR14463 trip on earth faults from variable frequency drives (VFDs)?

A: VFDs, LED drivers, and switched-mode power supplies generate high-frequency leakage currents that can cause nuisance tripping in standard Type AC RCCBs. If your installation includes VFDs, use a Type A (for pulsating DC components) or Type F/B RCCB. The A9KR14463 specification (AC or A type) determines suitability — check the product marking.

Q: Which Schneider Electric accessories are compatible with the A9KR14463?

A: The Schneider Electric A9KR14463 series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the A9KR14463.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “A9KR14463 | Acti 9K RCCB 4P 63A 300 mA AC-type – Schneider Electric”

Your email address will not be published. Required fields are marked *