C25N32D250 Circuit breaker, ComPacT NSX250N, 50kA 415VAC, 3 poles, MicroLogic 2.2 trip unit 250A Schneider Electric c25w32d25
C16N32D160 | Circuit breaker, ComPacT NSX160N, 50kA/415VAC, 3 poles, MicroLogic 2.2 trip unit 160A - Schneider Electric Original price was: ₹62,110.00.Current price is: ₹31,055.00. Excl. GST
Back to products
C16N3TM125 Circuit breaker, ComPacT NSX160N, 50kA 415VAC, 3 poles, TMD trip unit 125A Schneider Electric c16h3tm160 39910531
C16N3TM160 | Circuit breaker, ComPacT NSX160N, 50kA/415VAC, 3 poles, TMD trip unit 160A - Schneider Electric Original price was: ₹46,680.00.Current price is: ₹23,340.00. Excl. GST

C16N3TM125 | Circuit breaker, ComPacT NSX160N, 50kA/415VAC, 3 poles, TMD trip unit 125A – Schneider Electric

SKU: C16N3TM125

Original price was: ₹45,710.00.Current price is: ₹22,855.00. Excl. GST

In stock

In stock

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: C16N3TM125

Same-day dispatch · GST invoice available

11 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the C16N3TM125 | Circuit breaker, ComPacT NSX160N, 50kA/415VAC, 3 poles, TMD trip unit 125A? This genuine Schneider Electric mccb from the ComPacT range is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 125 A at 40 °C, 690 V AC 50/60 Hz, 3P. Order part number C16N3TM125 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUC16N3TM125
CategoryMCCB
Main
RangeComPacT
Product nameComPacT NSX
Device short nameNSX160N
Product or component typeCircuit breaker
Device applicationDistribution
Poles description3P
Protected poles description3D
[In] rated current125 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1
50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1
10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Breaking capacity codeN 50 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service breaking capacity90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability40000 cycles
Electrical durability40000 cycles at 440 V In/2
20000 cycles at 440 V In
15000 cycles at 690 V In/2
7500 cycles at 690 V In
Power dissipation per pole10.78 W
Mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
Downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating125 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7…1 x In
Long-time protection delay adjustment type trFixed
[tr] long-time delay adjustment range120…400 s at 1.5 x In
15 s at 6 x Ir
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range1250 A
Earth-leakage protectionWithout
Number of slots5 slot(s)
Width (W)105 mm
Height (H)161 mm
Depth (D)86 mm
Product weight2.2 kg
Environment
StandardsEN/IEC 60947-2
Overvoltage categoryIII
Electrical shock protection classClass II on front face
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.200 cm
Package 1 Width11.500 cm
Package 1 Length19.600 cm
Package 1 Weight1.838 kg
Unit Type of Package 2S03
Number of Units in Package 27
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight13.250 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 160 A frame rating — handles the full rated current continuously; designed for feeder and sub-distribution protection where fault levels exceed MCB capability.
  • Performance level N — breaking capacity 50 kA (normal high breaking, for industrial main distribution boards).
  • TMD (Thermal-Magnetic) trip unit — adjustable overload setting (Ir) from 0.7–1× In with fixed instantaneous magnetic trip; simple and reliable for standard feeder applications.
  • 3 Poles — three-phase feeder protection; neutral not switched (TN-C / IT systems).
  • CompacT NSX form factor — 70mm wide per pole; designed for high-density LV switchboards with up to 3 units per standard 250mm busbar bay.
  • Rotary handle with padlocking points — LOTO compliant; handle locks in OFF position with up to 3 padlocks, preventing accidental energisation during maintenance.
  • Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LV429354TLV429517LV429515LV429329LV4294882945029452LV429387LV429388LV429407LV429408LV429337TLV429338TLV429434LV429289LV429454LV429513

❓ Frequently Asked Questions

Q: What load can the C16N3TM125 protect at its rated 160 A?

A: The C16N3TM125 is rated to carry and protect circuits up to 160 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 160 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 50 kA breaking capacity on the C16N3TM125 mean in practice?

A: Breaking capacity (50 kA) is the maximum prospective short-circuit current the C16N3TM125 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 50 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: Can the C16N3TM125 be motorised for remote switching and automation?

A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.

Q: What trip unit type does the C16N3TM125 use — thermal-magnetic or electronic?

A: The C16N3TM125 uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.

Q: Is the C16N3TM125 suitable for use as a motor branch circuit protector (Type E coordination)?

A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.

Customer Reviews