CA2KN22E7 TeSys K control relay 2 NO 2 NC ca2kn22m7 image 1500x1500
CA2KN22F7 | TeSys K control relay - 2 NO + 2 NC - <= 690 V - 110 V AC coil - Schneider Electric Original price was: ₹3,090.00.Current price is: ₹1,390.50. Excl. GST
Back to products
CA2KN22N7 TeSys K control relay 2 NO 2 NC odaca2kn22n7 bis 1500x1500
CA2KN22N7 | TeSys K control relay - 2 NO + 2 NC - <= 690 V - 400...415 V AC coil - Schneider Electric Original price was: ₹3,090.00.Current price is: ₹1,390.50. Excl. GST

CA2KN22M7 | TeSys K control relay – 2 NO + 2 NC – <= 690 V - 220...230 V AC coil - Schneider Electric

SKU: CA2KN22M7

Original price was: ₹3,090.00.Current price is: ₹1,390.50. Excl. GST

In stock

In stock

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: CA2KN22M7

Same-day dispatch · GST invoice available

18 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Sourced through authorised channels, the Schneider Electric CA2KN22M7 relay from the TeSys range delivers dependable performance for motor control and switching. Key ratings include <= 690 V <= 400 Hz, IP2X. myelectric.in stocks the CA2KN22M7 | TeSys K control relay - 2 NO + 2 NC - <= 690 V - 220...230 V AC coil for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUCA2KN22M7
CategoryRelay
Main
RangeTeSys
Product nameTeSys CAK
Product or component typeControl relay
Device short nameCA2K
Contactor applicationControl circuit
Utilisation categoryAC-15
DC-13
Pole contact composition2 NO + 2 NC
[Ue] rated operational voltage<= 690 V <= 400 Hz
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage220…230 V AC 50/60 Hz
Complementary
[Ith] conventional free air thermal current10 A (at 50 °C)
Irms rated making capacity110 A conforming to IEC 60947
Associated fuse rating10 A gG conforming to IEC 60947
10 A gG conforming to VDE 0660
[Ui] rated insulation voltage690 V conforming to IEC 60947
750 V conforming to VDE 0110 group C
690 V conforming to BS 5424
600 V conforming to CSA C22.2 No 14
Mounting supportRail
Plate
Connections – terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…1.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible without cable end
Tightening torque1.3 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
1.3 N.m – on screw clamp terminals – with screwdriver Philips No 26 mm
1.3 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Control circuit voltage limitsDrop-out: 0.2…0.75 Uc (at <50 °C)
Operational: 0.8…1.15 Uc (at <50 °C)
Operating time10…20 ms coil de-energisation and NO opening
10…20 ms coil energisation and NO closing
15…25 ms coil de-energisation and NC closing
5…15 ms coil energisation and NC opening
Mechanical durability10 Mcycles
Maximum operating rate10000 cyc/h
Immunity to microbreaks2 ms
Inrush power in VA30 VA (at 20 °C)
Hold-in power consumption in VA4.5 VA (at 20 °C)
Heat dissipation1.3 W
Minimum switching voltage17 V
Minimum switching current5 mA
Non overlap distance0.5 mm
Insulation resistance> 10 MOhm
Height58 mm
Width45 mm
Depth57 mm
Product weight0.18 kg
Environment
StandardsEN/IEC 60947-5-1
GB/T 14048.5
UL 60947-5-1
CSA C22.2 No 60947-5-1
JIS C8201-5-1
Product certificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protectionIP2X
Protective treatmentTC conforming to IEC 60068
Ambient air temperature for operation-25…50 °C
Ambient air temperature for storage-50…80 °C
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Mechanical robustnessVibrations contactor open: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations contactor closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
Shocks contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width6.100 cm
Package 1 Length4.800 cm
Package 1 Weight178.000 g
Unit Type of Package 2S02
Number of Units in Package 250
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.230 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 2 NO (normally-open) contacts for load switching and sequencing; 2 NC (normally-closed) contacts for interlocking, fail-safe, and alarm circuits — all contacts independently switchable up to the contact voltage rating.
  • 220–230V AC coil — energises from PLC digital output (transistor or relay type), timer contact, or pushbutton; no separate relay driver card required.
  • Contact voltage rating 690V AC — switches 230V AC loads (solenoid valves, motor starters, indicator lamps) and DC loads (PLC inputs, LED panels) within the same contact rating.
  • TeSys K control relay — identical DIN rail footprint to TeSys D contactors; accepts LA1KN auxiliary contact blocks for additional NO/NC outputs; mountable on 35mm or 20mm DIN rail.
  • Manufactured to IEC 60947-5-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LA1KN22LA1KN40LA1KN31LA1KN04LA1KN13LA2KT2ULA4KA1ULA4KE1UG

❓ Frequently Asked Questions

Q: The CA2KN22M7 has a coil voltage of 220–230V AC — what control supply is needed?

A: This Schneider Electric device requires a 220–230V AC control supply connected to the coil terminals (A1 and A2). For AC coils, ensure the control circuit voltage is stable — voltage drops below 85% of rated coil voltage can cause chatter and coil overheating. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.

Q: What circuit can the 2 NO + 2 NC contacts of the CA2KN22M7 switch at 690V AC?

A: The 2 NO + 2 NC contacts on the CA2KN22M7 are rated for switching at up to 690V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.

Q: How do I test the CA2KN22M7 relay in the field without a signal source?

A: Most Schneider Electric relays can be manually forced using the test button (if fitted) — this mechanically closes the relay contacts without energising the coil, allowing functional testing of the controlled circuit. For coil testing, use a multimeter to measure coil resistance (typically 500–2000Ω for AC coils at rated voltage) and compare with datasheet values.

Q: Can the CA2KN22M7 relay be mounted on a DIN rail socket for easy replacement?

A: This Schneider Electric relay typically requires direct panel or DIN rail wiring. For applications requiring frequent relay replacement, consider the plug-in relay variant of this series with a matching socket base.

Customer Reviews