CAD50E7 TeSys D control relay 5 NO cad50e7 image 1500x1500
CAD50E7 | TeSys D control relay - 5 NO - <= 690 V - 48 V AC standard coil - Schneider Electric Original price was: ₹3,605.00.Current price is: ₹1,622.25. Excl. GST
Back to products
CAD50FD TeSys D control relay 5 NO cad50fd image 1500x1500
CAD50FD | TeSys D control relay - 5 NO - <= 690 V - 110 V DC standard coil - Schneider Electric Original price was: ₹4,760.00.Current price is: ₹2,284.80. Excl. GST

CAD50F7 | TeSys D control relay – 5 NO – <= 690 V - 110 V AC standard coil - Schneider Electric

SKU: CAD50F7

Original price was: ₹3,310.00.Current price is: ₹1,489.50. Excl. GST

In stock

In stock

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: CAD50F7

Same-day dispatch · GST invoice available

17 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Sourced through authorised channels, the Schneider Electric CAD50F7 relay from the TeSys range delivers dependable performance for motor control and switching. Key ratings include <= 690 V AC 25...400 Hz, IP2X front face. myelectric.in stocks the CAD50F7 | TeSys D control relay - 5 NO - <= 690 V - 110 V AC standard coil for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUCAD50F7
CategoryRelay
Main
RangeTeSys
TeSys Deca
Product nameTeSys CAD
Product or component typeControl relay
Device short nameCAD
Contactor applicationControl circuit
Complementary
Utilisation categoryDC-13
AC-15
AC-14
Pole contact composition5 NO
[Ue] rated operational voltage<= 690 V AC 25…400 Hz
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage110 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
[Ith] conventional free air thermal current10 A (at 60 °C)
Irms rated making capacity140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
[Icw] rated short-time withstand current100 A – 1 s
120 A – 500 ms
140 A – 100 ms
Associated fuse rating10 A gG conforming to IEC 60947-5-1
[Ui] rated insulation voltage600 V UL certified
600 V CSA certified
690 V conforming to IEC 60947-5-1
Mounting supportRail
Plate
Connections – terminalsScrew clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Tightening torque1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Operating time12…22 ms coil energisation and NO closing
4…12 ms coil de-energisation and NO opening
Mechanical durability30 Mcycles
Maximum operating rate180 cyc/mn
Inrush power in VA70 VA 50 Hz (at 20 °C)
Hold-in power consumption in VA8 VA 50 Hz (at 20 °C)
Minimum switching voltage17 V
Minimum switching current5 mA
Non-overlap time1.5 ms on energisation between NC and NO contact
1.5 ms on de-energisation between NC and NO contact
Insulation resistance> 10 MOhm
Mechanical robustnessShocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations control relay open: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations control relay closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
Height77 mm
Width45 mm
Depth84 mm
Product weight0.58 kg
Environment
StandardsEN/IEC 60947-5-1
GB/T 14048.5
UL 60947-5-1
CSA C22.2 No 60947-5-1
JIS C8201-5-1
Product certificationsCB
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protectionIP2X front face conforming to VDE 0106
Protective treatmentTH conforming to IEC 60068
Ambient air temperature for operation-40…60 °C
60…70 °C with derating
Ambient air temperature for storage-60…80 °C
Operating altitude0…3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.5 cm
Package 1 Width10 cm
Package 1 Length12 cm
Package 1 Weight360 g
Unit Type of Package 2S02
Number of Units in Package 216
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight6.27 kg
Unit Type of Package 3P06
Number of Units in Package 3256
Package 3 Height75 cm
Package 3 Width60 cm
Package 3 Length80 cm
Package 3 Weight104.868 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 5 NO (normally-open) contacts for load switching and sequencing — all contacts independently switchable up to the contact voltage rating.
  • 110V AC coil — energises from PLC digital output (transistor or relay type), timer contact, or pushbutton; no separate relay driver card required.
  • Contact voltage rating 690V AC — switches 230V AC loads (solenoid valves, motor starters, indicator lamps) and DC loads (PLC inputs, LED panels) within the same contact rating.
  • TeSys K control relay — identical DIN rail footprint to TeSys D contactors; accepts LA1KN auxiliary contact blocks for additional NO/NC outputs; mountable on 35mm or 20mm DIN rail.
  • Manufactured to IEC 60947-5-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LAD9ET1SLAD4VGLAD4RCGLADN22LADN11LADN20LAD8N11LADT2LADN40LADN31LADN02LADT0LAD8N20LADS2LADR2LADR0LADN04LADN13LADR4LADT4LADN22SLADC22LADN10LAD6K10MLAD6K10FLAD6K10BLAD6K10ELXD1F7

❓ Frequently Asked Questions

Q: The CAD50F7 has a coil voltage of 110V AC — what control supply is needed?

A: This Schneider Electric device requires a 110V AC control supply connected to the coil terminals (A1 and A2). For AC coils, ensure the control circuit voltage is stable — voltage drops below 85% of rated coil voltage can cause chatter and coil overheating. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.

Q: What circuit can the 5 NO (Normally Open) contacts of the CAD50F7 switch at 690V AC?

A: The 5 NO (Normally Open) contacts on the CAD50F7 are rated for switching at up to 690V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.

Q: How do I test the CAD50F7 relay in the field without a signal source?

A: Most Schneider Electric relays can be manually forced using the test button (if fitted) — this mechanically closes the relay contacts without energising the coil, allowing functional testing of the controlled circuit. For coil testing, use a multimeter to measure coil resistance (typically 500–2000Ω for AC coils at rated voltage) and compare with datasheet values.

Q: Can the CAD50F7 relay be mounted on a DIN rail socket for easy replacement?

A: This Schneider Electric relay typically requires direct panel or DIN rail wiring. For applications requiring frequent relay replacement, consider the plug-in relay variant of this series with a matching socket base.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “CAD50F7 | TeSys D control relay – 5 NO – <= 690 V - 110 V AC standard coil - Schneider Electric”

Your email address will not be published. Required fields are marked *