LC1D1506BD | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 150 A - 24 V DC standard coil - Schneider Electric

SKU: LC1D1506BD

82,865.00 Excl. GST

Out of stock

Out of stock

20 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1D1506BD | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 150 A - 24 V DC standard coil? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 200 A, Power circuit: <= 1000 V AC 25...400 Hz, 3P. Order part number LC1D1506BD from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1D1506BD
CategoryContactor
Main
RangeTeSys
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-1
AC-4
AC-3e
Poles description3P
[Ue] rated operational voltagePower circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage24 V DC
Complementary
Motor power kW40 kW at 220…230 V AC 50/60 Hz (AC-3)
75 kW at 380…400 V AC 50/60 Hz (AC-3)
80 kW at 415…440 V AC 50/60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
100 kW at 660…690 V AC 50/60 Hz (AC-3)
75 kW at 1000 V AC 50/60 Hz (AC-3)
22 kW at 400 V AC 50/60 Hz (AC-4)
40 kW at 220…230 V AC 50/60 Hz (AC-3e)
75 kW at 380…400 V AC 50/60 Hz (AC-3e)
80 kW at 415…440 V AC 50/60 Hz (AC-3e)
90 kW at 500 V AC 50/60 Hz (AC-3e)
100 kW at 660…690 V AC 50/60 Hz (AC-3e)
75 kW at 1000 V AC 50/60 Hz (AC-3e)
Motor power hp40 hp at 200/208 V AC 50/60 Hz for 3 phases motors
50 hp at 230/240 V AC 50/60 Hz for 3 phases motors
100 hp at 460/480 V AC 50/60 Hz for 3 phases motors
125 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current200 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1660 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1400 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current250 A 40 °C – 10 min for power circuit
580 A 40 °C – 1 min for power circuit
1200 A 40 °C – 10 s for power circuit
1400 A 40 °C – 1 s for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
315 A gG at <= 690 V coordination type 1 for power circuit
250 A gG at <= 690 V coordination type 2 for power circuit
Average impedance0.6 mOhm – Ith 200 A 50 Hz for power circuit
Power dissipation per pole24 W AC-1
13.5 W AC-3
13.5 W AC-3e
[Ui] rated insulation voltagePower circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947
Safety reliability levelB10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability8 Mcycles
Electrical durability0.85 Mcycles 150 A AC-3 at Ue <= 440 V
1 Mcycles 200 A AC-1 at Ue <= 440 V
0.85 Mcycles 150 A AC-3e at Ue <= 440 V
Control circuit typeDC standard
Coil technologyWith integral suppression device
Control circuit voltage limits0.75…1.2 Uc (-40…55 °C):operational DC
0.15…0.4 Uc (-40…70 °C):drop-out DC
1…1.2 Uc (55…70 °C):operational DC
Inrush power in W270…365 W (at 20 °C)
Hold-in power consumption in W2.4…5.1 W at 20 °C
Operating time20…35 ms closing
40…75 ms opening
Time constant25 ms
Maximum operating rate1200 cyc/h at 60 °C
Connections – terminalsControl circuit: lugs-ring terminals – external diameter: 8 mm
Power circuit: lugs-ring terminals – external diameter: 25 mm
Power circuit: bars 1 – busbar cross section: 5 x 25 mm
Tightening torqueControl circuit: 1.2 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm M3.5
Control circuit: 1.2 N.m – on lugs-ring terminals – with screwdriver Philips No 2 M3.5
Power circuit: 12 N.m – on lugs-ring terminals hexagonal screw head 13 mm M8
Power circuit: 12 N.m – on bars hexagonal screw head 13 mm M8
Control circuit: 1.2 N.m – on lugs-ring terminals – with screwdriver pozidriv No 2 M3.5
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting supportRail
Plate
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
IEC 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Product certificationsUL
CCC
CSA
CE
UKCA
Marine
EAC
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height158 mm
Width120 mm
Depth136 mm
Product weight2.5 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height19.000 cm
Package 1 Width17.500 cm
Package 1 Length21.500 cm
Package 1 Weight2.207 kg
Unit Type of Package 2P06
Number of Units in Package 227
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight71.212 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 150 A AC-3 rated — suits up to a 75 kW squirrel-cage induction motor at 415V for direct-on-line (DOL) starting and running.
  • 24V DC coil — connects directly to pushbutton station, PLC digital output, or timer relay; suitable for standard 50Hz Indian industrial control circuits.
  • 3 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
  • Main contacts rated up to 440V AC — compatible with 415V AC three-phase Indian supply and 480V AC North American systems.
  • TeSys D series — world-standard contactor footprint; clip-on LA1D/LA4D auxiliary contact blocks and accessories attach without tools; compatible with TeSys LRD overload relays for direct-mount DOL starters.
  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

GV7AC03LA4DB3BLADN226LADN116LADN406LADN206LADN316LADN046LADN136LADT46LX4D8BD

❓ Frequently Asked Questions

Q: Is the LC1D1506BD rated 150 A for AC-3 motor duty or AC-1 resistive duty?

A: The 150 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.

Q: The LC1D1506BD has a coil voltage of 24V DC — what control supply is needed?

A: This Schneider Electric device requires a 24V DC control supply connected to the coil terminals (A1 and A2). For DC coils, observe polarity where marked. DC coils produce no inrush and are preferred for PLC output cards. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.

Q: What circuit can the 3 NO (Normally Open) contacts of the LC1D1506BD switch at 440V AC?

A: The 3 NO (Normally Open) contacts on the LC1D1506BD are rated for switching at up to 440V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.

Q: Can the LC1D1506BD be used for reversing duty (forward/reverse motor control)?

A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.

Q: Can multiple LC1D1506BD contactors be wired for star-delta starting?

A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.

Customer Reviews