25A 30MA FP Caretron RCCB Indoasian Image
25A 30MA FP Caretron RCCB - Indoasian Original price was: ₹3,780.00.Current price is: ₹1,701.00. Excl. GST
Back to products
25A 300MA FP Caretron RCCB Indoasian Image
25A 300MA FP Caretron RCCB - Indoasian Original price was: ₹3,847.00.Current price is: ₹1,731.15. Excl. GST

25A 100MA FP Caretron RCCB – Indoasian

SKU: 810162

Original price was: ₹3,847.00.Current price is: ₹1,731.15. Excl. GST

13 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Indoasian 810162 is a rccb, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 25 A, 4 Poles. Buy the 25A 100MA FP Caretron RCCB online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

ParameterValue
BrandIndoasian
Part Number / SKU810162
CategoryRCCB
Series / ModelCaretron
Current Rating25 A
Poles4 Poles
Sensitivity100 mA
Rated Voltage415V AC (3-phase 4-wire)
Rated Frequency50 Hz
Max Break Time≤ 300 ms at rated IΔn (per IEC 61008-1)
RCD TypeType AC (sinusoidal AC sensitive)
Protection FunctionEarth leakage only — pair with upstream MCB for overcurrent
Mounting35mm DIN rail (EN 60715)
Test FacilityBuilt-in test button (monthly test per IS 12640)
StandardIS 8828 / IEC 60898-1
CertificationsBIS certified (ISI mark)

⚡ Key Features

  • 100 mA sensitivity — intermediate sensitivity — used for fire protection and equipment earth-fault monitoring where a 30mA device would nuisance-trip.
  • 25 A rated load current — the RCCB carries this full circuit current continuously while monitoring the live-neutral balance for any earth leakage.
  • 4 Poles — for three-phase four-wire (TN-S/TT) installations; all four conductors pass through the toroidal CT for complete leakage detection.
  • Earth-leakage protection only — no overload or short-circuit protection; install in series with an appropriately rated MCB for full circuit protection.
  • Mandatory test button — simulate a leakage fault to verify the trip mechanism without live fault conditions; test monthly per IS 12640 recommendation.
  • Type AC — designed for purely sinusoidal AC residual currents on standard residential and commercial circuits.
  • Caretron SP (1 Pole): for single-phase branch circuit protection up to 63A
  • Manufactured to IEC 61008 / IS 12640-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified (ISI mark) — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Indoasian product — sourced directly from the official distribution network with full manufacturer traceability and warranty.

❓ Frequently Asked Questions

Q: What is the significance of the 25 A rating on the 810162?

A: The 25 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.

Q: Why is the 100 mA sensitivity specified on the 810162 and when should you choose a different rating?

A: 100 mA is the residual current at which the 810162 will trip within 300ms. A 30mA sensitivity provides additional shock protection (mandatory for socket circuits per IS 732). 100mA is used for fire protection (no shock protection). 300mA protects feeders without nuisance tripping. Choose based on the circuit’s risk profile — never use >30mA for socket outlet circuits in wet or high-risk locations.

Q: How many downstream circuits can be protected under the 810162 without nuisance tripping?

A: Downstream MCBs or RCBOs can be connected below the 810162, but the total standing leakage current of all connected circuits must not exceed 30–50% of the RCCB’s rated sensitivity — typically 9–15mA for a 30mA device. Each appliance with a filter (computers, VFDs, LED drivers) contributes 0.5–3mA of standing leakage, so limit the count of such loads per RCCB to prevent cumulative leakage causing nuisance tripping.

Q: Will the 810162 trip on earth faults from variable frequency drives (VFDs)?

A: VFDs, LED drivers, and switched-mode power supplies generate high-frequency leakage currents that can cause nuisance tripping in standard Type AC RCCBs. If your installation includes VFDs, use a Type A (for pulsating DC components) or Type F/B RCCB. The 810162 specification (AC or A type) determines suitability — check the product marking.

Q: Which Indoasian accessories are compatible with the 810162?

A: The Indoasian Caretron series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Indoasian product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the 810162.