AU RCCB 40A DP 240V Adi 100mA L T AURAD204010 aurad204003 au r rccb 40 a 30ma adi 2p front
AU RCCB 40A DP 240V Adi 30mA | L&T - AURAD204003 Original price was: ₹7,805.00.Current price is: ₹3,590.30. Excl. GST
Back to products
AU RCCB 40A DP 240V Adi 100mA L T AURAD204010 aurad204003 au r rccb 40 a 30ma adi 2p front
AU RCCB 100A DP 240V Adi 30mA | L&T - AURAD210003 Original price was: ₹13,490.00.Current price is: ₹6,205.40. Excl. GST

AU RCCB 63A DP 240V Adi 30mA | L&T – AURAD206303

SKU: AURAD206303

Original price was: ₹9,130.00.Current price is: ₹4,199.80. Excl. GST

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: AURAD206303

Same-day dispatch · GST invoice available

10 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

📋 Technical Specifications

ParameterValue
BrandAURAD206303
Part Number / SKUAURAD206303
CategoryRCCB
Current Rating63 A
Voltage Rating240V AC
Poles2 Poles
Sensitivity30 mA
StandardIEC 61008 / IS 12640-1
CertificationsBIS certified where applicable

⚡ Key Features

  • 30 mA sensitivity — standard personnel shock protection — trips before a lethal current (>50mA) can flow through the body (IEC 61008).
  • 63 A rated load current — the RCCB carries this full circuit current continuously while monitoring the live-neutral balance for any earth leakage.
  • 2 Poles — for single-phase circuits; both live and neutral pass through the sensing core.
  • Earth-leakage protection only — no overload or short-circuit protection; install in series with an appropriately rated MCB for full circuit protection.
  • Mandatory test button — simulate a leakage fault to verify the trip mechanism without live fault conditions; test monthly per IS 12640 recommendation.
  • Type AC — designed for purely sinusoidal AC residual currents on standard residential and commercial circuits.
  • Manufactured to IEC 61008 / IS 12640-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised AURAD206303 product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.

❓ Frequently Asked Questions

Q: What is the significance of the 63 A rating on the AURAD206303?

A: The 63 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.

Q: Why is the 30 mA sensitivity specified on the AURAD206303 and when should you choose a different rating?

A: 30 mA is the residual current at which the AURAD206303 will trip within 300ms. A 30mA sensitivity provides additional shock protection (mandatory for socket circuits per IS 732). 100mA is used for fire protection (no shock protection). 300mA protects feeders without nuisance tripping. Choose based on the circuit’s risk profile — never use >30mA for socket outlet circuits in wet or high-risk locations.

Q: Will the AURAD206303 trip on earth faults from variable frequency drives (VFDs)?

A: VFDs, LED drivers, and switched-mode power supplies generate high-frequency leakage currents that can cause nuisance tripping in standard Type AC RCCBs. If your installation includes VFDs, use a Type A (for pulsating DC components) or Type F/B RCCB. The AURAD206303 specification (AC or A type) determines suitability — check the product marking.

Q: How many downstream circuits can be protected under the AURAD206303 without nuisance tripping?

A: Downstream MCBs or RCBOs can be connected below the AURAD206303, but the total standing leakage current of all connected circuits must not exceed 30–50% of the RCCB’s rated sensitivity — typically 9–15mA for a 30mA device. Each appliance with a filter (computers, VFDs, LED drivers) contributes 0.5–3mA of standing leakage, so limit the count of such loads per RCCB to prevent cumulative leakage causing nuisance tripping.

Q: What is the difference between an RCCB and a standard MCB — and why use the AURAD206303?

A: A standard MCB protects against overload and short-circuit only. An RCCB adds earth leakage (residual current) detection — it trips on faults as low as 30mA to ground, protecting against electric shock and fire from insulation faults, which a standard MCB cannot detect. Choose the AURAD206303 when the application specifically requires rccb characteristics.