Tripper RCBO(EL+MCB) 16A FP 415V AC 6kA 300mA C Curve | L&T – CB90006OOBO
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
The CB90006OOBO CB90006OOBO is a miniature circuit breaker (mcb), engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 16 A, 415V AC, 4 Poles. Buy the Tripper RCBO(EL+MCB) 16A FP 415V AC 6kA 300mA C Curve | L&T online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | CB90006OOBO |
| Part Number / SKU | CB90006OOBO |
| Category | Miniature Circuit Breaker (MCB) |
| Current Rating | 16 A |
| Voltage Rating | 415V AC |
| Poles | 4 Poles |
| Breaking Capacity | 6 kA |
| Tripping Curve | Curve C |
| Sensitivity | 300 mA |
| Rated Voltage | 230/400V AC |
| Rated Frequency | 50/60 Hz |
| Magnetic Trip Range | 5–10 × In (per IEC 60898-1) |
| Trip Mechanism | Thermal-magnetic (bimetal overload + electromagnetic short-circuit) |
| Mounting | 35mm DIN rail (EN 60715) |
| Width | 72 mm (4 × 18mm modules) |
| Electrical Endurance | ≥ 20,000 operating cycles (per IEC 60898-1) |
| Pollution Degree | 3 (per IEC 60664-1) |
| Standard | IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) |
| Certifications | BIS certified where applicable |
⚡ Key Features
- Protects circuits at 16 A with 6 kA short-circuit breaking capacity — rated for residential and commercial final circuits.
- Curve C tripping characteristic — optimised for general-purpose and inductive loads (motors, mixed circuits) — trips magnetically at 5–10× rated current.
- 4 Poles — protects a three-phase four-wire circuit with switched neutral; fits standard 35mm DIN rail in distribution boards.
- Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
- Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised CB90006OOBO product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What load can the CB90006OOBO protect at its rated 16 A?
A: The CB90006OOBO is rated to carry and protect circuits up to 16 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 16 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 6 kA breaking capacity on the CB90006OOBO mean in practice?
A: Breaking capacity (6 kA) is the maximum prospective short-circuit current the CB90006OOBO can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 6 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Why is Curve C specified for the CB90006OOBO and what loads is it optimised for?
A: Curve C on the CB90006OOBO trips magnetically at 5–10× rated current, making it ideal for general-purpose circuits including fluorescent lamps, small motors, and mixed loads. Using the wrong curve can cause nuisance tripping (too sensitive) or inadequate protection (not sensitive enough). Always match the curve to the load’s inrush characteristics.
Q: Why is the 300 mA sensitivity specified on the CB90006OOBO and when should you choose a different rating?
A: 300 mA is the residual current at which the CB90006OOBO will trip within 300ms. A 30mA sensitivity provides additional shock protection (mandatory for socket circuits per IS 732). 100mA is used for fire protection (no shock protection). 300mA protects feeders without nuisance tripping. Choose based on the circuit’s risk profile — never use >30mA for socket outlet circuits in wet or high-risk locations.
Q: Is the CB90006OOBO suitable for both single-phase and three-phase systems?
A: The CB90006OOBO with 4 Poles can protect three-phase circuits. Each pole simultaneously interrupts one phase — ensuring all phases are de-energised on a fault.













Reviews
Clear filtersThere are no reviews yet.