DN4N MCCB 800 4P 415V AC 50kA MTX1.0 50/60 Hz | L&T – CM96111OOOOX1
₹138,300.00 Original price was: ₹138,300.00.₹63,618.00Current price is: ₹63,618.00. Excl. GST
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
The CM96111OOOOX1 CM96111OOOOX1 is a mccb, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 415V AC, 4 Poles. Buy the DN4N MCCB 800 4P 415V AC 50kA MTX1.0 50/60 Hz | L&T online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | CM96111OOOOX1 |
| Part Number / SKU | CM96111OOOOX1 |
| Category | MCCB |
| Voltage Rating | 415V AC |
| Poles | 4 Poles |
| Breaking Capacity | 50 kA |
| Frequency | 60 Hz |
| Rated Operational Voltage (Ue) | 415V AC (50/60 Hz) |
| Mounting | Fixed, front connected |
| Rated Frequency | 50/60 Hz |
| Standard | IEC 60947-2 / IS 13947-2 |
| Certifications | BIS certified where applicable |
⚡ Key Features
- 50 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
- Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
- 4 Poles — three-phase + switched neutral (TN-S system) for full four-pole isolation per IEC 60364.
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised CM96111OOOOX1 product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What does the 50 kA breaking capacity on the CM96111OOOOX1 mean in practice?
A: Breaking capacity (50 kA) is the maximum prospective short-circuit current the CM96111OOOOX1 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 50 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Can the CM96111OOOOX1 be motorised for remote switching and automation?
A: Yes. CM96111OOOOX1 MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: What trip unit type does the CM96111OOOOX1 use — thermal-magnetic or electronic?
A: Refer to the product label or datasheet for the exact trip unit specification. The trip unit determines adjustability and protection accuracy.
Q: Is the CM96111OOOOX1 suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the CM96111OOOOX1 coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.
Q: After a short-circuit trip on the CM96111OOOOX1, can it be reset and reused immediately?
A: After a short-circuit trip, do not immediately reset the CM96111OOOOX1. First, identify and clear the fault. Then inspect the device — if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 50 kA rated breaking capacity is not unlimited — it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1–3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.