Back to products
C10V3TM040 NSX100HB1 75kA AC 3P 40A TMD Schneider Electric c10v3tm040
C10V3TM040 | NSX100HB1 75kA AC 3P 40A TMD - Schneider Electric Original price was: ₹125,250.00.Current price is: ₹60,120.00. Excl. GST

LTMR27PBD | Controller Profibus 1,35 27A 24Vdc – Schneider Electric

SKU: LTMR27PBD

135,875.00 Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: LTMR27PBD

Same-day dispatch · GST invoice available

12 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Schneider Electric LTMR27PBD is an electrical component from the TeSys range, engineered for industrial, commercial, and infrastructure applications in demanding Indian and international installations. Key ratings include 27 A, IP20. Buy the LTMR27PBD | Controller Profibus 1,35 27A 24Vdc online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULTMR27PBD
CategoryElectrical Component
Main
RangeTeSys
Product nameTeSys T
Device short nameLTMR
Product or component typeMotor controller
Device applicationEquipment monitoring and control
Measurement current1.35…27 A
[Us] rated supply voltage24 V DC
Current consumption56…127 mA
Supply voltage limits20.4…26.24 V DC
Communication port protocolProfibus DP
Bus typeProfibus DP polarised 2-wire RS485 interface, addressing 1…125, transmission rate 9.6 kbit/s…12 Mbit/s, SUB-D 9 with 2 shielded twisted pairs, type A
Profibus DP polarised 2-wire RS485 interface, addressing 1…125, transmission rate 9.6 kbit/s…12 Mbit/s, terminal block with 2 shielded twisted pairs, type A
Complementary
[Ui] rated insulation voltage690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
[Uimp] rated impulse withstand voltage6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
Short-circuit withstand100 kA conforming to EN/IEC 60947-4-1
Associated fuse rating4 A gG for output
0.5 A gG for control circuit
Protection typeOverload
Thermal protection
Power factor variation
Overload (long time)
Phase failure
Load fluctuation
Phase unbalance
Locked rotor
Earth-leakage protection
Thermal overload protection
Reverse polarity protection
Network and machine diagnosis typeStarting current and time
Fault recording
Remaining operating time before overload tripping
Motor control command recording
Running hours counter/operating time
Trip context information
Trip history information
Phase fault and earth fault trip counters
Event recording
Waiting time after overload tripping
Logic input number6
Input current7 mA
Current state 0 guaranteedLogic input: < 5 V and <= 15 mA for 5 ms
Current state 1 guaranteedLogic input: < 15 V and 2…15 mA for 15 ms
maximum output switching frequency2 Hz
Load current5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
Permissible power480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
maximum operating rate1800 cyc/h
Contacts type and composition1 NO + 1 NC fault signal
3 NO
Metering typeAverage current Iavg
Temperature
Imbalance current
Phase current I1, I2, I3 RMS
Earth-fault current
Measurement accuracy5…15 % earth fault current internal measurement
1 % voltage (100…830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power
Overvoltage categoryIII
Connection pitch5.08 mm
Connections – terminalsControl circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) solid without cable end
Tightening torqueControl circuit: 0.5…0.6 N.m flat screwdriver 3 mm
Pollution degree3
Electromagnetic compatibilityElectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Width91 mm
Height61 mm
Depth122.5 mm
Product weight0.53 kg
Web servicesWeb server
Compatibility codeLTMR
Environment
StandardsUL 508
IACS E10
EN 60947-4-1
IEC 60947-4-1
CSA C22.2 No 14
Product certificationsC-Tick
CCC
ABS
NOM
LROS (Lloyds register of shipping)
EAC
RINA
ATEX
GL
KERI
DNV
UL
CSA
RMRoS
BV
Protective treatment12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
Fire resistance650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
Ambient air temperature for operation-20…60 °C
Ambient air temperature for storage-40…80 °C
Operating altitude<= 2000 m without derating
Mechanical robustnessVibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
IP degree of protectionIP20
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.2 cm
Package 1 Width10.0 cm
Package 1 Length13.6 cm
Package 1 Weight514.0 g
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight5.485 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 27 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
  • Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LTM9CU10LTM9CU30

❓ Frequently Asked Questions

Q: What is the significance of the 27 A rating on the LTMR27PBD?

A: The 27 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.

Customer Reviews