LC1D1150046U7 | CONTACTOR 115A 4P 240V 50 60HZ – Schneider Electric
₹67,515.00 Excl. GST
Out of stock
Out of stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LADN406 | TeSys CONTACTS BLOCK – Schneider Electric
LADN206 | TeSys CONTACTS BLOCK – Schneider Electric
LADN316 | TeSys CONTACTS BLOCK – Schneider Electric
LADN116 | TeSys CONTACTS BLOCK – Schneider Electric
LA4DA2U | TeSys D – suppressor module – RC circuit – 110…240 V AC – Schneider Electric
LA4DE2U | VARISTOR SUPPRES 110-250VAC FOR D80-D115 – Schneider Electric
LADN046 | TeSys CONTACTS BLOCK – Schneider Electric
LADT46 | TeSys CONTACTS BLOCK – Schneider Electric
LADN226 | TeSys CONTACTS BLOCK – Schneider Electric
LADN136 | TeSys CONTACTS BLOCK – Schneider Electric
Looking for the LC1D1150046U7 | CONTACTOR 115A 4P 240V 50 60HZ? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 200 A, Power circuit: <= 1000 V AC 25...400 Hz, 4P. Order part number LC1D1150046U7 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LC1D1150046U7 |
| Category | Contactor |
| Main | |
| Range | TeSys |
| Range of product | TeSys Deca |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load |
| Utilisation category | AC-1 AC-3 AC-3e AC-4 |
| Poles description | 4P |
| [Ue] rated operational voltage | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC |
| [Ie] rated operational current | 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 240 V AC 50/60 Hz |
| Complementary | |
| Compatibility code | LC1D |
| Pole contact composition | 4 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 200 A (at 60 °C) for power circuit |
| Irms rated making capacity | 1260 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 250 A 40 °C – 10 min for power circuit 550 A 40 °C – 1 min for power circuit 950 A 40 °C – 10 s for power circuit 1100 A 40 °C – 1 s for power circuit |
| Associated fuse rating | 250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 0.6 mOhm – Ith 200 A 50 Hz for power circuit |
| Power dissipation per pole | 24 W AC-1 |
| [Ui] rated insulation voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 8 Mcycles |
| Electrical durability | 0.8 Mcycles 200 A AC-1 at Ue <= 440 V |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.3…0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8…1.15 Uc (-40…55 °C):operational AC 50/60 Hz 1…1.15 Uc (55…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 280…350 VA 60 Hz cos phi 0.8 (at 20 °C) 280…350 VA 50 Hz cos phi 0.8 (at 20 °C) |
| Hold-in power consumption in VA | 2…18 VA 60 Hz cos phi 0.3 (at 20 °C) 2…18 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 3…8 W at 50/60 Hz |
| Operating time | 6…20 ms opening 20…50 ms closing |
| Maximum operating rate | 2400 cyc/h at 60 °C |
| Connections – terminals | Control circuit: lugs-ring terminals – external diameter: 8 mm Power circuit: lugs-ring terminals – external diameter: 25 mm Power circuit: bars 1 – busbar cross section: 5 x 25 mm |
| Tightening torque | Control circuit: 1.2 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm M3.5 Control circuit: 1.2 N.m – on lugs-ring terminals – with screwdriver Philips No 2 M3.5 Power circuit: 12 N.m – on lugs-ring terminals hexagonal screw head 13 mm M8 Power circuit: 12 N.m – on bars hexagonal screw head 13 mm M8 Control circuit: 1.2 N.m – on lugs-ring terminals – with screwdriver pozidriv No 2 |
| Mounting support | Rail Plate |
| Environment | |
| Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1 |
| Product certifications | CCC DNV GL CSA GOST BV UL LROS (Lloyds register of shipping) RINA UKCA |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C 60…70 °C with derating |
| Operating altitude | 0…3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5…300 Hz) Vibrations contactor closed (4 Gn, 5…300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms) |
| Height | 158 mm |
| Width | 155 mm |
| Depth | 115 mm |
| Product weight | 2.86 kg |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 16.8 cm |
| Package 1 Width | 21.2 cm |
| Package 1 Length | 18.5 cm |
| Package 1 Weight | 2.37 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 115 A AC-3 rated — suits up to a 55 kW squirrel-cage induction motor at 415V for direct-on-line (DOL) starting and running.
- 4 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
- Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: Is the LC1D1150046U7 rated 115 A for AC-3 motor duty or AC-1 resistive duty?
A: The 115 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.
Q: Can the LC1D1150046U7 be used for reversing duty (forward/reverse motor control)?
A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.
Q: Can multiple LC1D1150046U7 contactors be wired for star-delta starting?
A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.
Q: What is the electrical and mechanical life of the LC1D1150046U7?
A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.
Q: Which Schneider Electric accessories are compatible with the LC1D1150046U7?
A: The Schneider Electric LC1D1150046U7 series supports snap-on accessories including auxiliary contact blocks, coil surge suppressors, mechanical interlocks, and direct-mount overload relays. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the LC1D1150046U7.