SLPWTXX Sensor, Wall, Temp, Touchscreen, Bacnet Modbus, Optimum White Schneider Electric slpwtxx
SLPWTXX | Sensor, Wall, Temp, Touchscreen, Bacnet/Modbus, Optimum White - Schneider Electric Original price was: ₹30,882.00.Current price is: ₹17,911.56. Excl. GST
Back to products
LC1D95M5 POWER CONTACTOR-LC1-D95 95A 220VAC 3P Schneider Electric lc1d95m5
LC1D95M5 | POWER CONTACTOR-LC1-D95 95A 220VAC 3P - Schneider Electric Original price was: ₹45,660.00.Current price is: ₹20,547.00. Excl. GST

LP1D65008FD | TeSys D contactor – 4P(2 NO + 2 NC) – AC-1 – <= 440 V 80 A - 110 V DC coil - Schneider Electric

SKU: LP1D65008FD

Original price was: ₹45,285.00.Current price is: ₹20,378.25. Excl. GST

Dispatch By : 8 Weeks

Dispatch By : 8 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: LP1D65008FD

Same-day dispatch · GST invoice available

16 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LP1D65008FD | TeSys D contactor – 4P(2 NO + 2 NC) – AC-1 – <= 440 V 80 A - 110 V DC coil? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 80 A, Power circuit: <= 1000 V AC 25...400 Hz, 4P. Order part number LP1D65008FD from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULP1D65008FD
CategoryContactor
Main
RangeTeSys
Range of productTeSys Deca
Product or component typeContactor
Device short nameLP1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit: <= 1000 V AC 25…400 Hz
[Ie] rated operational current80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage110 V DC
Complementary
Compatibility codeLP1D
Pole contact composition2 NO + 2 NC
Protective coverWith
[Ith] conventional free air thermal current80 A (at 60 °C) for power circuit
Irms rated making capacity1000 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current110 A 40 °C – 10 min for power circuit
260 A 40 °C – 1 min for power circuit
520 A 40 °C – 10 s for power circuit
900 A 40 °C – 1 s for power circuit
Associated fuse rating125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
Average impedance1.5 mOhm – Ith 80 A 50 Hz for power circuit
Power dissipation per pole9.6 W AC-1
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability10 Mcycles
Electrical durability1.5 Mcycles 80 A AC-1 at Ue <= 440 V
Control circuit typeDC DC standard
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.1…0.3 Uc (-40…55 °C):drop-out DC
0.85…1.1 Uc (-40…55 °C):operational DC
Inrush power in W22 W (at 20 °C)
Hold-in power consumption in W22 W at 20 °C
Operating time4…19 ms opening
12…26 ms closing
Time constant75 ms
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsPower circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: solid
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid
Tightening torquePower circuit: 8 N.m – on screw clamp terminals – cable 25…35 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 5 N.m – on screw clamp terminals – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Mounting supportPlate
Rail
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
Product certificationsUL
CSA
CCC
EAC
UKCA
CB
DNV-GL
RINA
BV
LROS (Lloyds register of shipping)
IP degree of protectionIP20 front face conforming to IEC 60529
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessShocks contactor open (8 Gn for 11 ms)
Shocks contactor closed (10 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Height127 mm
Width85 mm
Depth182 mm
Product weight2.22 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height19.5 cm
Package 1 Width10.0 cm
Package 1 Length14.0 cm
Package 1 Weight2.255 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 80 A AC-3 rated — suits up to a 37 kW squirrel-cage induction motor at 415V for direct-on-line (DOL) starting and running.
  • 110V DC coil — connects directly to pushbutton station, PLC digital output, or timer relay; suitable for standard 50Hz Indian industrial control circuits.
  • 4 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
  • Main contacts rated up to 440V AC — compatible with 415V AC three-phase Indian supply and 480V AC North American systems.
  • TeSys D series — world-standard contactor footprint; clip-on LA1D/LA4D auxiliary contact blocks and accessories attach without tools; compatible with TeSys LRD overload relays for direct-mount DOL starters.
  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LAD9ET1SLA4DC3ULADN22LADN11LADN20LADT2LADN40LADN31LADN02LADT0LADS2LADR2LADR0LADN04LADN13LADR4LADT4

❓ Frequently Asked Questions

Q: Is the LP1D65008FD rated 80 A for AC-3 motor duty or AC-1 resistive duty?

A: The 80 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.

Q: The LP1D65008FD has a coil voltage of 110V DC — what control supply is needed?

A: This Schneider Electric device requires a 110V DC control supply connected to the coil terminals (A1 and A2). For DC coils, observe polarity where marked. DC coils produce no inrush and are preferred for PLC output cards. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.

Q: What circuit can the 2 NO + 2 NC contacts of the LP1D65008FD switch at 440V AC?

A: The 2 NO + 2 NC contacts on the LP1D65008FD are rated for switching at up to 440V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.

Q: What is the electrical and mechanical life of the LP1D65008FD?

A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.

Q: Can the LP1D65008FD be used for reversing duty (forward/reverse motor control)?

A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.