LV510473 | Easypact 40A, 50Ka, 3Pole Mccb - Schneider Electric
LV510473 | Easypact 40A, 50Ka, 3Pole Mccb - Schneider Electric Original price was: ₹24,920.00.Current price is: ₹11,463.20. Excl. GST
Back to products
LV510476 | Easypact 80A, 50Ka, 3Pole Mccb - Schneider Electric
LV510476 | Easypact 80A, 50Ka, 3Pole Mccb - Schneider Electric Original price was: ₹24,920.00.Current price is: ₹11,463.20. Excl. GST

LV510470 | Easypact 16A, 50Ka, 3Pole Mccb – Schneider Electric

SKU: LV510470

Original price was: ₹24,920.00.Current price is: ₹11,463.20. Excl. GST

Dispatch By : 3 Weeks

Dispatch By : 3 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: LV510470

Same-day dispatch · GST invoice available

11 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Sourced through authorised channels, the Schneider Electric LV510470 mccb from the EasyPact range delivers dependable performance for reliable circuit protection and isolation. Key ratings include 16 A at 40 °C, 3P, IP40. myelectric.in stocks the LV510470 | Easypact 16A, 50Ka, 3Pole Mccb for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULV510470
CategoryMCCB
Main
RangeEasyPact
Range of productEasyPact CVS100…250
Product nameEasyPact CVS
Device short nameCVS100N
Product or component typeCircuit breaker
Device applicationDistribution
Poles description3P
Protected poles description3D
Earth leakage protection (Vigi add on)Without
[In] rated current16 A at 40 °C
Network typeAC
Utilisation categoryCategory A
[Icu] Breaking capacity50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
80 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating16 A at 40 °C
Protection typeShort-circuit protection (magnetic)
Overload protection (thermal)
Complementary
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Breaking capacity codeN
[Ics] rated service breaking capacity30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
80 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability30000 cycles
Electrical durability12000 cycles 415 V In conforming to IEC 60947-2
Control typeToggle
Thermal protection adjustment range0…16 A
Long time pick-up adjustment type IrAdjustable
Long time pick-up adjustment range0.7…1 x In
Long time delay adjustment typeFixed
Short-time delay adjustment typeFixed
Instantaneous pick-up adjustment type IiFixed
Instantaneous pick-up adjustment range190 A
Contact position indicatorYes
Mounting supportBackplate
Mounting modeFixed
Upside connectionFront
Downside connectionFront
Connections – terminalsScrew connection
Connection pitch35 mm
Compatibility codeCVS100
Width105 mm
Depth86 mm
Height161 mm
Product weight1.5 kg
Environment
StandardsIEC 60947-2
EN 60947-2
Product certificationsGOST
IEC
Electrical shock protection classClass II
IP degree of protectionIP40
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.094 cm
Package 1 Width13.695 cm
Package 1 Length18.884 cm
Package 1 Weight1.822 kg
Unit Type of Package 2S02
Number of Units in Package 24
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.592 kg
Unit Type of Package 3P12
Number of Units in Package 364
Package 3 Height45.000 cm
Package 3 Width80.000 cm
Package 3 Length120.000 cm
Package 3 Weight133.472 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 50 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
  • Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
  • 3 Poles — three-phase feeder protection; neutral not switched (TN-C / IT systems).
  • Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LV429329LV429337LV429338LV429515LV429517LV43156329450LV429387LV429407LV429451

❓ Frequently Asked Questions

Q: What load can the LV510470 protect at its rated 16 A?

A: The LV510470 is rated to carry and protect circuits up to 16 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 16 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 50 kA breaking capacity on the LV510470 mean in practice?

A: Breaking capacity (50 kA) is the maximum prospective short-circuit current the LV510470 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 50 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: What trip unit type does the LV510470 use — thermal-magnetic or electronic?

A: Refer to the product label or datasheet for the exact trip unit specification. The trip unit determines adjustability and protection accuracy.

Q: Is the LV510470 suitable for use as a motor branch circuit protector (Type E coordination)?

A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.

Q: Can the LV510470 be motorised for remote switching and automation?

A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.