28913 | INS160 4P 160 A – Schneider Electric
₹20,360.00 Original price was: ₹20,360.00.₹17,509.60Current price is: ₹17,509.60. Excl. GST
Out of stock
Out of stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
28953 | MECHANICAL INTERLOCK INS40/160 – Schneider Electric
29450 | standard auxiliary contact, circuit breaker status OF-SD-SDE-SDV, 1 single contact – Schneider Electric
28943 | EXTENDED LATERALE ROT. HANDEL INS40 A 1 – Schneider Electric
LV428941 | EXTENDED FRONT ROT. HANDLE INS 40A TO 16 – Schneider Electric
Looking for the INS160 4P 160 A? This genuine Schneider Electric electrical component from the ComPact range is built for industrial, commercial, and infrastructure applications, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include AC-23A: 160 A AC 50/60 Hz 500 V, 250 V DC, 4P. Order part number 28913 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | 28913 |
| Category | Electrical Component |
| Main | |
| Range | ComPact |
| Product name | ComPacT INS |
| Product or component type | Switch disconnector |
| Poles description | 4P |
| Network type | AC DC |
| Network frequency | 50/60 Hz |
| [Ie] rated operational current | AC-23A: 160 A AC 50/60 Hz 500 V AC-22A: 160 A AC 50/60 Hz 220/240 V AC-22A: 160 A AC 50/60 Hz 380/415 V AC-22A: 160 A AC 50/60 Hz 440/480 V AC-22A: 160 A AC 50/60 Hz 500 V AC-22A: 160 A AC 50/60 Hz 660/690 V AC-23A: 160 A AC 50/60 Hz 660/690 V AC-23A: 160 A AC 50/60 Hz 220/240 V AC-23A: 160 A AC 50/60 Hz 380/415 V AC-23A: 160 A AC 50/60 Hz 440/480 V DC-22A: 160 A DC 125 V 2 poles in series DC-23A: 160 A DC 125 V 2 poles in series DC-22A: 160 A DC 250 V 4 poles in series DC-23A: 160 A DC 250 V 4 poles in series |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ith] conventional free air thermal current | 160 A at 60 °C |
| [Icm] rated short-circuit making capacity | 154 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz 20 kA switch-disconnector alone 690 V AC at 50/60 Hz |
| [Ue] rated operational voltage | 250 V DC 690 V AC 50/60 Hz |
| Suitability for isolation | Yes |
| Contact position indicator | Yes |
| Visible break | No |
| Pollution degree | 3 |
| Complementary | |
| Control type | Rotary handle |
| Handle colour | Black |
| Mounting mode | Fixed |
| Mounting support | Plate DIN rail |
| Upside connection | Front |
| Downside connection | Front |
| Maximum power | AC-23: 110 kW at 500/525 V AC 50/60 Hz AC-23: 45 kW at 220/240 V AC 50/60 Hz AC-23: 75 kW at 380/415 V AC 50/60 Hz AC-23: 90 kW at 440 V AC 50/60 Hz AC-23: 90 kW at 660/690 V AC 50/60 Hz |
| Rated duty | Uninterrupted |
| Intermittent duty class | Class 120 – 60 % |
| [Icw] rated short-time withstand current | 1 kA during 30 s conforming to IEC 60947-3 1.23 kA during 20 s conforming to IEC 60947-3 3.175 kA during 3 s conforming to IEC 60947-3 5.5 kA during 1 s conforming to IEC 60947-3 |
| Mechanical durability | 15000 cycles |
| Electrical durability | AC-22A: 1500 cycles 220/240 V AC 50/60 Hz AC-22A: 1500 cycles 380/415 V AC 50/60 Hz AC-22A: 1500 cycles 440 V AC 50/60 Hz AC-22A: 1500 cycles 500 V AC 50/60 Hz AC-23A: 1500 cycles 220/240 V AC 50/60 Hz AC-23A: 1500 cycles 380/415 V AC 50/60 Hz AC-23A: 1500 cycles 440 V AC 50/60 Hz AC-23A: 1500 cycles 500 V AC 50/60 Hz DC-22A: 1500 cycles 250 V DC 4 poles in series DC-23A: 1500 cycles 250 V DC 4 poles in series AC-22A: 1500 cycles 690 V AC 50/60 Hz AC-23A: 1500 cycles 690 V AC 50/60 Hz |
| Connection pitch | 30 mm |
| Height | 100 mm |
| Width | 135 mm |
| Depth | 62.5 mm |
| Product weight | 0.9 kg |
| Environment | |
| Standards | IEC 60947-1 IEC 60947-3 |
| Product certifications | CCC KEMA-KEUR |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to EN 50102 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13.400 cm |
| Package 1 Width | 11.000 cm |
| Package 1 Length | 15.000 cm |
| Package 1 Weight | 1.123 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 11.594 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 80 |
| Package 3 Height | 44.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 106.000 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 160 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
- Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What is the significance of the 160 A rating on the 28913?
A: The 160 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.