EZC250H2125 | Mccb-Easypact Ezc, Ezc250H2125, 125A, 85Ka, 2Pole Mccb – Schneider Electric
₹16,210.00 Original price was: ₹16,210.00.₹8,105.00Current price is: ₹8,105.00. Excl. GST
Dispatch By : 2 Weeks
Dispatch By : 2 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
EZEROTDS | Rotary handle – for EZC250,EZCV250 – black handle black front plate – direct mtg – Schneider Electric
EZESHT200AC | shunt trip release SHT – 200..240 V AC – for EZ250 – Schneider Electric
EZEROTE | Rotary handle – for EZC250, EZCV250 – black hdl black front plate – extended mtg – Schneider Electric
EZEAXAL | Mccb Accessory-Easypact Cvs Accessory,Ezeaxal,Alarm-Auxiliary Switch For Ezc250 – Schneider Electric
EZESPDR3P | pitch spreader – 3 poles – for EZC250, EZCV250 – set of 3 – Schneider Electric
EZEUVR200AC | EZ250 BOBINA DE MINIMA TENSION 200 240VA – Schneider Electric
EZEAL | Mccb Accessory-Easypact Cvs Accessory,Ezeal,Alarm Switch 1 C/O For Ezc250 – Schneider Electric
EZEAX | auxiliary contact – for Easypact EZ250 – Schneider Electric
Looking for the EZC250H2125 | Mccb-Easypact Ezc, Ezc250H2125, 125A, 85Ka, 2Pole Mccb? This genuine Schneider Electric mccb from the EasyPact range is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 125 A at 40 °C, 550 V AC 50/60 Hz, 2P. Order part number EZC250H2125 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | EZC250H2125 |
| Category | MCCB |
| Main | |
| Range of product | EasyPact |
| Product or component type | Circuit breaker |
| Device short name | Easypact EZC250H |
| Circuit breaker name | Easypact EZC250H |
| Device application | Distribution |
| Poles description | 2P |
| Protected poles description | 2t |
| Network type | AC DC |
| Network frequency | 50/60 Hz |
| [In] rated current | 125 A at 40 °C |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 |
| Breaking capacity code | H |
| Breaking capacity | 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity | 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 125 A at 50 °C |
| Protection type | Short-circuit protection Overload protection |
| Pollution degree | 3 conforming to IEC 60664-1 3 conforming to IEC 947-1 |
| Complementary | |
| Control type | Toggle |
| Mounting mode | Fixed |
| Mounting support | Backplate |
| Upside connection | Front |
| Downside connection | Front |
| Mechanical durability | 10000 cycles |
| Connection pitch | 35 mm |
| Local signalling | Positive contact indication |
| Neutral protection setting | Without protection |
| Earth-leakage protection | Without |
| Height | 165 mm |
| Width | 105 mm |
| Depth | 60 mm |
| Environment | |
| Standards | EN/IEC 60947-1 EN/IEC 60947-2 GB/T 14048.2 JIS C8201-2-2 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -35…85 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.400 cm |
| Package 1 Width | 11.300 cm |
| Package 1 Length | 18.000 cm |
| Package 1 Weight | 1.480 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 12.327 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 85 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
- Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
- 2 Poles — protects the connected feeder circuit.
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What load can the EZC250H2125 protect at its rated 125 A?
A: The EZC250H2125 is rated to carry and protect circuits up to 125 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 125 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 85 kA breaking capacity on the EZC250H2125 mean in practice?
A: Breaking capacity (85 kA) is the maximum prospective short-circuit current the EZC250H2125 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 85 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Can the EZC250H2125 be motorised for remote switching and automation?
A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: What trip unit type does the EZC250H2125 use — thermal-magnetic or electronic?
A: Refer to the product label or datasheet for the exact trip unit specification. The trip unit determines adjustability and protection accuracy.
Q: Is the EZC250H2125 suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.