LAEX3F7 | COIL 110V 50/60Hz LC1E40-65 3P – Schneider Electric
₹7,280.00 Original price was: ₹7,280.00.₹4,004.00Current price is: ₹4,004.00. Excl. GST
Dispatch By : 2 Weeks
Dispatch By : 2 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LC1E50F7 | Easy TeSys contactor 3P(3 NO) – AC-3 – <= 440 V 50A - 110 V AC coil - Schneider Electric
LC1E40F7 | Easy TeSys contactor 3P(3 NO) – AC-3 – <= 440 V 40A - 110 V AC coil - Schneider Electric
LC1E65F7 | Easy TeSys contactor 3P(3 NO) – AC-3 – <= 440 V 65A - 110 V AC coil - Schneider Electric
The Schneider Electric LAEX3F7 is a contactor spare part from the Easy TeSys range, engineered for motor control and switching in demanding Indian and international installations. Key ratings include 110V AC, 3 Poles. Buy the LAEX3F7 | COIL 110V 50/60Hz LC1E40-65 3P online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LAEX3F7 |
| Category | Contactor Spare Part |
| Main | |
| Range | Easy TeSys |
| Range of product | Easy TeSys Control |
| Product or component type | Contactor coil |
| Device short name | LAEX |
| Product compatibility | LC1E40…E65 |
| Control circuit type | AC at 50/60 Hz standard |
| [Uc] control circuit voltage | 110 V AC 50/60 Hz |
| Average resistance | 34.4 Ohm at 20 °C |
| Inductance of closed circuit | 1.93 H |
| Complementary | |
| Control circuit voltage limits | Operational: 0.85…1.1 Uc at 50/60 Hz (at <60 °C) |
| Inrush power in VA | 160 VA 50 Hz cos phi 0.75 (at 20 °C) 140 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 15 VA 50 Hz cos phi 0.3 (at 20 °C) 13 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Environment | |
| Ambient air temperature for operation | -5…60 °C |
| Product weight | 0.11 kg |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.5 cm |
| Package 1 Width | 8.2 cm |
| Package 1 Length | 11.4 cm |
| Package 1 Weight | 116.8 g |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Genuine Schneider Electric OEM accessory — manufactured to the same specification and tested to the same standards as the parent device; ensures mechanical and electrical compatibility that third-party alternatives cannot guarantee.
- Replacement contactor coil rated 110V AC — restores the original contactor to service at a fraction of the cost of a complete replacement.
- Exact-fit replacement — same electrical and mechanical specification as the factory-fitted coil; no recalibration or adjustment of the contactor required after fitting.
- Direct clip-on or screw-mount to parent device — fits without panel modification or additional wiring between the accessory and main device; field-retrofittable.
- Manufactured to IEC 60947 (tested as part of the parent device certification) — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: The LAEX3F7 has a coil voltage of 110V AC — what control supply is needed?
A: This Schneider Electric device requires a 110V AC control supply connected to the coil terminals (A1 and A2). For AC coils, ensure the control circuit voltage is stable — voltage drops below 85% of rated coil voltage can cause chatter and coil overheating. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.
Q: How do I know the LAEX3F7 replacement coil matches my contactor?
A: Match three things: (1) the contactor series and frame size stated for the LAEX3F7, (2) the coil voltage — the replacement must equal the control circuit voltage exactly, and (3) AC or DC supply type. Fitting a coil of the wrong voltage causes failure to pull in (too low) or coil burnout (too high). The original coil’s voltage is printed on its face — verify before ordering.
Q: What causes a contactor coil to fail and need replacement like the LAEX3F7?
A: The most common causes are: sustained undervoltage (coil hums and overheats while failing to seal the magnetic circuit), overvoltage, voltage spikes from nearby switching inductive loads, dust or rust on the magnet faces preventing full closure (coil draws inrush current continuously), and simple ageing of the insulation. If coils fail repeatedly, fit a surge suppressor and check the control supply voltage stability before fitting the new coil.












