Showing 1–12 of 15 resultsSorted by popularity
Product categories
Filter by Brand
- Multispan 15
VOLTAGE & CURRENT PROTECTION RELAY - DIN RAIL
SPP-22 (Single Phase preventor ) VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 90 X 22.5 X 67.5 MULTISPAN
Voltage Range : 280 to 520V AC (P-P), Output : 1 Relay
Tripping Facility : Phase asymmetry, Phase Loss, Phase sequence,
Supply : Self Powered
CR-3K VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 90 X 35 X 63 MULTISPAN
Current Range : 100mA to 5A AC(3CT Input)
Tripping Facility : Over Current , Under Current, Output -1 Relay
Supply : 100 -270V AC
VR-3KN VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 90 X 35 X 63 MULTISPAN
Voltage Range : 280 to 520V AC (P-P), Output : 1R2C/O
Tripping Facility : Over voltage, Under voltage, Phase asymmetry, Phase loss, Phase sequence,Neutral Loss Supply : Self Powered
VR-3K VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 90 X 35 X 63 MULTISPAN
Voltage Range : 280 to 520V AC (P-P), Output : 1R2C/O
Tripping Facility : Over voltage, Under voltage, Phase asymmetry, Phase loss, Phase sequence
Supply : Self Powered
V22-RYB (Single Phase preventor ) VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 90 X 22.5 X 72 MULTISPAN
Voltage Range : 280 to 520V AC (P-P), Output : 1 Relay
Tripping Facility : Phase asymmetry, Phase Loss, Phase sequence,
Supply : Self Powered
SPP-22-1 (Single Phase preventor ) VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 90 X 22.5 X 67.5 MULTISPAN
Voltage Range : 280 to 520V AC (P-P), Output : 1 Relay
Tripping Facility : Phase asymmetry, Phase Loss,
Supply : Self Powered
VPR-22U VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 90 X 22.5 X 72 MULTISPAN
Voltage Range : 280 to 520V AC (P-P), Output : 1 Relay
Tripping Facility : Over voltage, Under voltage, Phase asymmetry, Phase loss, Phase sequence,With Selectable Trip Delay Time
Supply : Self Powered
VPR-22 VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 90 X 22.5 X 72 MULTISPAN
Voltage Range : 280 to 520V AC (P-P), Output : 1 Relay
Tripping Facility : Over voltage, Under voltage, Phase asymmetry, Phase loss, Phase sequence
Supply : Self Powered
CPR-35-3C VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 75 X 45 X 110 MULTISPAN
Current Range : 0 to 999A AC,(3CT Input)
Tripping Facility : Over Current , Under Current, SPP, Asmmetry,Output -1 Relay
Supply : 100 -270V AC
CPR-35-1C VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 75 X 45 X 110 MULTISPAN
Current Range : 0 to 999A AC,(1CT Input) Tripping Facility : Over Current , Under Current, Asmmetry,Output -1 Relay
Supply : 100 -270V AC
OLR-3060 VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 70 X 55 X 65 MULTISPAN
Current Range : 10A to 60A AC(3CT) Tripping Facility : Over Current Output -1 Relay
Supply : 230V AC
OLR-1030 VOLTAGE & CURRENT PROTECTION RELAY – DIN RAIL 70 X 55 X 65 MULTISPAN
Current Range : 5A to 30A AC(3CT) Tripping Facility : Over Current Output -1 Relay
Supply : 230V AC