1SYF204015R3250 | FB204 AC-25/0.3; Residual Current Circuit Breaker; 4P; 25A; 300mA; AC-Type - ABB
1SYF204015R3250 | FB204 AC-25/0.3; Residual Current Circuit Breaker; 4P; 25A; 300mA; AC-Type - ABB Original price was: ₹6,370.00.Current price is: ₹2,548.00. Excl. GST
Back to products
1SYD274115R0063 | SDB204/63; Switch Disconnector; 4P; 63A - ABB
1SYD274115R0063 | SDB204/63; Switch Disconnector; 4P; 63A - ABB Original price was: ₹2,140.00.Current price is: ₹856.00. Excl. GST

1SYS273012R0634 | MCB, SB200M – 63A 3P (TP) C Curve 10kA – ABB

SKU: 1SYS273012R0634

Original price was: ₹3,160.00.Current price is: ₹1,264.00. Excl. GST

11 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the 1SYS273012R0634 | MCB, SB200M – 63A 3P (TP) C Curve 10kA? This genuine ABB miniature circuit breaker (mcb) is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 63 A, 3 Poles. Order part number 1SYS273012R0634 from myelectric.in — a trusted ABB supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

ParameterValue
BrandABB
Part Number / SKU1SYS273012R0634
CategoryMiniature Circuit Breaker (MCB)
Current Rating63 A
Poles3 Poles
Breaking Capacity10 kA
Tripping CurveCurve C
Rated Voltage230/400V AC
Rated Frequency50/60 Hz
Magnetic Trip Range5–10 × In (per IEC 60898-1)
Trip MechanismThermal-magnetic (bimetal overload + electromagnetic short-circuit)
Mounting35mm DIN rail (EN 60715)
Width54 mm (3 × 18mm modules)
Electrical Endurance≥ 20,000 operating cycles (per IEC 60898-1)
Pollution Degree3 (per IEC 60664-1)
StandardIS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial)
CertificationsBIS certified, CE, KEMA tested

⚡ Key Features

  • Protects circuits at 63 A with 10 kA short-circuit breaking capacity — rated for light industrial and commercial distribution boards.
  • Curve C tripping characteristic — optimised for general-purpose and inductive loads (motors, mixed circuits) — trips magnetically at 5–10× rated current.
  • 3 Poles — protects a three-phase circuit without neutral; fits standard 35mm DIN rail in distribution boards.
  • Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
  • Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE, KEMA tested — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised ABB product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

❓ Frequently Asked Questions

Q: What load can the 1SYS273012R0634 protect at its rated 63 A?

A: The 1SYS273012R0634 is rated to carry and protect circuits up to 63 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 63 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 10 kA breaking capacity on the 1SYS273012R0634 mean in practice?

A: Breaking capacity (10 kA) is the maximum prospective short-circuit current the 1SYS273012R0634 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 10 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: Why is Curve C specified for the 1SYS273012R0634 and what loads is it optimised for?

A: Curve C on the 1SYS273012R0634 trips magnetically at 5–10× rated current, making it ideal for general-purpose circuits including fluorescent lamps, small motors, and mixed loads. Using the wrong curve can cause nuisance tripping (too sensitive) or inadequate protection (not sensitive enough). Always match the curve to the load’s inrush characteristics.

Q: Can the 1SYS273012R0634 be DIN rail mounted in any standard distribution board?

A: Yes. This ABB MCB uses the standard 35mm EN 60715 DIN rail and 17.5mm module width, making it compatible with all major brand distribution boards and enclosures. Terminal capacity accommodates both rigid and flexible conductors up to the rated cross-section.

Q: What happens when the 1SYS273012R0634 trips — how do I identify and reset it?

A: When the 1SYS273012R0634 trips on fault, the handle moves to a midway position (between ON and OFF), distinctly visible from a distance. To reset: (1) identify and rectify the fault, (2) push the handle fully to OFF, (3) then switch back to ON. Never force-reset without investigating the fault cause.

Customer Reviews