3RA19211DA00 | Siemens Sirius Link Module Electrical and Mechanical Suitable For 3RV2 & 3RT2 Contactor, Size S00 - Siemens
3RA19211DA00 | Siemens Sirius Link Module Electrical and Mechanical Suitable For 3RV2 & 3RT2 Contactor, Size S00 - Siemens Original price was: ₹1,120.00.Current price is: ₹515.20. Excl. GST
Back to products
3RV2041-4FA10 | Siemens Sirius 3RV2 MPCB 28 - 40 A, Standard Release, Overload & Short Circuit, Class 10, Size S3 - Siemens
3RV2041-4FA10 | Siemens Sirius 3RV2 MPCB 28 - 40 A, Standard Release, Overload & Short Circuit, Class 10, Size S3 - Siemens Original price was: ₹58,940.00.Current price is: ₹25,933.60. Excl. GST

3RT2936-4EA2 | Siemens Sirius Terminal Cover 20.6 mm Suitable For 3RU2 Thermal Overload Relay Size S2 – Siemens

SKU: 3RT2936-4EA2

Original price was: ₹465.00.Current price is: ₹213.90. Excl. GST

Out of stock

Out of stock

13 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Siemens 3RT2936-4EA2 is an overload relay, engineered for motor control and switching in demanding Indian and international installations. Buy the 3RT2936-4EA2 | Siemens Sirius Terminal Cover 20.6 mm Suitable For 3RU2 Thermal Overload Relay Size S2 online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

ParameterValue
BrandSiemens
Part Number / SKU3RT2936-4EA2
CategoryOverload Relay
Series / Model3RT
Phase-Loss SensitivityYes — differential bimetal mechanism
Reset ModeManual / Automatic (selectable)
Auxiliary Contacts1 NO + 1 NC
MountingDirect mounting on matching contactor
Rated Frequency50/60 Hz
StandardIEC 60947-4-1, IS 13947
CertificationsBIS certified, CE, cULus (select models)

⚡ Key Features

  • Bimetal thermal element with phase-loss sensitivity — independently monitors each phase; trips if any phase carries more than ~115% of the set current, or on complete phase failure.
  • Normally open (NO) and normally closed (NC) auxiliary contacts built in — NO contact wired to motor run indicator; NC contact wired to PLC fault input or motor starter stop circuit.
  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE, cULus (select models) — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Siemens product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

❓ Frequently Asked Questions

Q: Does the 3RT2936-4EA2 provide single-phase (phase loss) protection?

A: Siemens thermal overload relays include single-phase sensitivity: if one phase is lost, the remaining phases carry higher current, causing the bimetal to heat and trip within the specified time. For critical motors, add a dedicated phase-loss relay for faster response independent of load — overload relay phase-loss protection is load-dependent and may take minutes to trip at light load.

Q: How do I set the 3RT2936-4EA2 to protect a motor without causing nuisance trips on starting?

A: Set the thermal overload dial to the motor’s nameplate full-load current (FLC). For star-delta starters, set the overload relay to 58% of motor FLC (line current in delta = FLC × 0.58). Allow 10 trips for the relay’s thermal memory to stabilise before adjusting the setting.

Q: What is the difference between an Overload Relay and a standard MCB — and why use the 3RT2936-4EA2?

A: A standard MCB protects against overload and short-circuit only. An Overload Relay provides thermal overload protection calibrated to motor FLC, protecting the motor from sustained overloads that would destroy windings before a standard MCB trips. Choose the 3RT2936-4EA2 when the application specifically requires overload relay characteristics.

Customer Reviews