3RV23314EC10 MPCB 22 32 A, Magnetic Release, S C Siemens g ic03 xx 08817i
3RV23314EC10 | MPCB 22 - 32 A, Magnetic Release, S/C - Siemens Original price was: ₹26,405.00.Current price is: ₹11,618.20. Excl. GST
Back to products
3RV23314WC10 MPCB 42 52 A, Magnetic Release, S C Siemens g ic03 xx 08846i
3RV23314KC10 | MPCB 62 - 73 A, Magnetic Release, S/C - Siemens Original price was: ₹38,550.00.Current price is: ₹16,962.00. Excl. GST

3RV23314JC10 | MPCB 54 – 65 A, Magnetic Release, S/C – Siemens

SKU: 3RV23314JC10

Original price was: ₹36,710.00.Current price is: ₹16,152.40. Excl. GST

Out of stock

Out of stock

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Siemens 3RV23314JC10 is a motor protection circuit breaker (mpcb), engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 54–65 A. Buy the 3RV23314JC10 | MPCB 54 – 65 A, Magnetic Release, S/C online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

ParameterValue
BrandSiemens
Part Number / SKU3RV23314JC10
CategoryMotor Protection Circuit Breaker (MPCB)
Series / Model3RV
Current Rating54–65 A
Trip ClassClass 10A (per IEC 60947-4-1)
Rated Operational VoltageUp to 690V AC
Rated Frequency50/60 Hz
Protection FunctionsThermal overload (adjustable), magnetic short-circuit, phase-loss
Mounting35mm DIN rail or screw fixing
ResetManual reset after trip
StandardIEC 60947-4-1, IEC 60947-2
CertificationsBIS certified, CE, cULus (select models)

⚡ Key Features

  • Continuously adjustable current range 54–65 A — dial to the motor’s exact nameplate full-load current (FLC) for optimum overload protection without nuisance tripping.
  • Combined thermal and magnetic protection in one device — single MPCB replaces a separate motor-rated MCB plus thermal overload relay, saving DIN rail space and inter-device wiring.
  • Phase-loss and phase-unbalance detection — trips within seconds of a phase failure, protecting the motor from the severe overheating that single-phasing causes within minutes.
  • Manual reset only — operator must acknowledge and reset the MPCB after a trip, preventing automatic restart that could damage the motor or driven machinery.
  • Manufactured to IEC 60947-4-1 and IEC 60947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE, cULus (select models) — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Siemens product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

❓ Frequently Asked Questions

Q: How do I set the 54–65 A adjustable range on the 3RV23314JC10 for my motor?

A: Turn the setting dial to the motor’s nameplate full-load current (FLC) — the FLC must fall within the 54–65 A range of this device. Setting it at the motor FLC (not the maximum of the range) gives correct overload trip timing while still riding through normal starting inrush. If the motor FLC is outside this range, select the adjacent rating in the same series.

Q: Can the 3RV23314JC10 replace a contactor + overload relay combination in a motor circuit?

A: The 3RV23314JC10 provides motor short-circuit protection and overload protection in one device — but it cannot make/break motor current under normal operational switching (that is the contactor’s role). For motor starters requiring on/off switching, the 3RV23314JC10 is used as the upstream protection device with a contactor for switching. Some MPCB series include a direct handle for manual starting of small motors without a separate contactor.

Q: What is the trip class of the 3RV23314JC10 and what motor starting time does it allow?

A: MPCBs are typically rated Class 10 (trips in ≤10 seconds at 7.2× setting current), suitable for normal motors with DOL starting times up to 10 seconds. Heavy-duty motors (large fans, centrifuges, compressors) with longer starting times may need Class 20 or Class 30 protection — check the starting time against the motor’s speed-torque curve and select accordingly.

Q: Which Siemens accessories are compatible with the 3RV23314JC10?

A: The Siemens 3RV series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Siemens product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the 3RV23314JC10.

Q: What is the difference between a Motor Protection Circuit Breaker (MPCB) and a standard MCB — and why use the 3RV23314JC10?

A: A standard MCB protects against overload and short-circuit only. A Motor Protection Circuit Breaker (MPCB) adds adjustable thermal overload matched to motor FLC, Class 10/20 trip curves for motor starting inrush, and phase-loss sensitivity — making it the correct device for motor branch circuits where a standard MCB would either nuisance-trip on motor starting or fail to protect adequately against slow overloads. Choose the 3RV23314JC10 when the application specifically requires motor protection circuit breaker (mpcb) characteristics.

Customer Reviews