3RV2711-1BD10 | circuit breaker frame size S00 for system protection with approval circuit breaker UL 489, CSA C22.2 no. 5-02 thermal overload release 2 A short-circuit release 26 A screw terminal standard switching capacity – Siemens
₹39,615.00 Original price was: ₹39,615.00.₹17,430.60Current price is: ₹17,430.60. Excl. GST
Out of stock
Out of stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
The Siemens 3RV2711-1BD10 is an overload relay, engineered for motor control and switching in demanding Indian and international installations. Key ratings include 2 A. Buy the 3RV2711-1BD10 | circuit breaker frame size S00 for system protection with approval circuit breaker UL 489, CSA C22.2 no. 5-02 thermal overload release 2 A short-circuit release 26 A screw terminal standard switching capacity online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Siemens |
| Part Number / SKU | 3RV2711-1BD10 |
| Category | Overload Relay |
| Series / Model | 3RV |
| Contact Configuration | 2 NO (Normally Open) |
| Current Rating | 2 A |
| Phase-Loss Sensitivity | Yes — differential bimetal mechanism |
| Reset Mode | Manual / Automatic (selectable) |
| Auxiliary Contacts | 1 NO + 1 NC |
| Mounting | Direct mounting on matching contactor |
| Rated Frequency | 50/60 Hz |
| Standard | IEC 60947-4-1, IEC 60947-2 |
| Certifications | BIS certified, CE, cULus (select models) |
⚡ Key Features
- Adjustable current range 2 A — set to the motor nameplate FLC for accurate overload detection; range covers multiple motor sizes from a single relay model.
- Bimetal thermal element with phase-loss sensitivity — independently monitors each phase; trips if any phase carries more than ~115% of the set current, or on complete phase failure.
- Normally open (NO) and normally closed (NC) auxiliary contacts built in — NO contact wired to motor run indicator; NC contact wired to PLC fault input or motor starter stop circuit.
- Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE, cULus (select models) — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Siemens product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What motor HP/kW is covered by the 2 A setting on the 3RV2711-1BD10?
A: The 2 A current range covers motors with full-load current (FLC) within that band. Set the overload relay to the motor’s nameplate FLC — not the maximum of the range — to ensure correct trip time and avoid nuisance tripping on motor starting inrush.
Q: What does the 2 NO (Normally Open) contact configuration on the 3RV2711-1BD10 mean?
A: These contacts change state when the device is operated or energised. Size the contact for the actual switched load — pilot duty ratings are typically lower than the main contact rating.
Q: Does the 3RV2711-1BD10 provide single-phase (phase loss) protection?
A: Siemens thermal overload relays include single-phase sensitivity: if one phase is lost, the remaining phases carry higher current, causing the bimetal to heat and trip within the specified time. For critical motors, add a dedicated phase-loss relay for faster response independent of load — overload relay phase-loss protection is load-dependent and may take minutes to trip at light load.
Q: How do I set the 3RV2711-1BD10 to protect a motor without causing nuisance trips on starting?
A: Set the thermal overload dial to the motor’s nameplate full-load current (FLC) — ensure the FLC is within the 2 A range of this relay. For star-delta starters, set the overload relay to 58% of motor FLC (line current in delta = FLC × 0.58). Allow 10 trips for the relay’s thermal memory to stabilise before adjusting the setting.
Q: What is the difference between an Overload Relay and a standard MCB — and why use the 3RV2711-1BD10?
A: A standard MCB protects against overload and short-circuit only. An Overload Relay provides thermal overload protection calibrated to motor FLC, protecting the motor from sustained overloads that would destroy windings before a standard MCB trips. Choose the 3RV2711-1BD10 when the application specifically requires overload relay characteristics.