3VA1192-5MG32-0AA0 MCCB 12.5 A, 3 Pole, 55 kA, Fixed S C, Magnetic Trip Unit, For Motor Starter Protection Siemens g i202 xx
3VA1192-5MG32-0AA0 | MCCB 12.5 A, 3 Pole, 55 kA, Fixed S/C, Magnetic Trip Unit, For Motor Starter Protection - Siemens Original price was: ₹28,925.00.Current price is: ₹12,727.00. Excl. GST
Back to products
3VA1196-4ED22-0AA0 MCCB 16 A, 2 Pole, 36 kA, Fixed O L Fixed S C Settings, Thermal Magnetic Trip Unit FTFM Siemens p i202 xx
3VA1196-3ED22-0AA0 | MCCB 16 A, 2 Pole, 25 kA, Fixed O/L & Fixed S/C Settings, Thermal Magnetic Trip Unit (FTFM) - Siemens Original price was: ₹14,615.00.Current price is: ₹6,430.60. Excl. GST

3VA1192-6MG32-0AA0 | MCCB 12.5 A, 3 Pole, 70 kA, Fixed S/C, Magnetic Trip Unit, For Motor Starter Protection – Siemens

SKU: 3VA1192-6MG32-0AA0

Original price was: ₹35,520.00.Current price is: ₹15,628.80. Excl. GST

Out of stock

Out of stock

13 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

📋 Technical Specifications

ParameterValue
BrandSiemens
Part Number / SKU3VA1192-6MG32-0AA0
CategoryMCCB
Current Rating12.5 A
Poles3 Poles
Breaking Capacity70 kA
StandardIEC 60947-2 / IS 13947-2
CertificationsBIS certified, CE, cULus (select models)

⚡ Key Features

  • 70 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
  • Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
  • 3 Poles — three-phase feeder protection; neutral not switched (TN-C / IT systems).
  • SENTRON 3VA series — optional display module shows current, voltage, and energy; add communication modules for SCADA/BMS integration without external metering.
  • Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE, cULus (select models) — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Siemens product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

❓ Frequently Asked Questions

Q: What load can the 3VA1192-6MG32-0AA0 protect at its rated 12.5 A?

A: The 3VA1192-6MG32-0AA0 is rated to carry and protect circuits up to 12.5 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 12.5 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 70 kA breaking capacity on the 3VA1192-6MG32-0AA0 mean in practice?

A: Breaking capacity (70 kA) is the maximum prospective short-circuit current the 3VA1192-6MG32-0AA0 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 70 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: What trip unit type does the 3VA1192-6MG32-0AA0 use — thermal-magnetic or electronic?

A: Refer to the product label or datasheet for the exact trip unit specification. The trip unit determines adjustability and protection accuracy.

Q: Is the 3VA1192-6MG32-0AA0 suitable for use as a motor branch circuit protector (Type E coordination)?

A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Siemens coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.

Q: Can the 3VA1192-6MG32-0AA0 be motorised for remote switching and automation?

A: Yes. Siemens MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.