5SL71107RC Betagard MCB 10 A, 1 Pole, 15 kA, C Curve Siemens siemens miniature circuit breaker 500 500 1
5SL71258RC | Betagard MCB 25 A, 1 Pole, 15 kA, D-Curve - Siemens Original price was: ₹705.00.Current price is: ₹324.30. Excl. GST
Back to products
5SL72408RC Betagard MCB 40 A, 2 Pole, 10 kA, D-Curve Siemens 5sl7 2p 465x560
5SL72027RC | Betagard MCB 2 A, 2 Pole, 15 kA, C-Curve - Siemens Original price was: ₹2,240.00.Current price is: ₹1,030.40. Excl. GST

5SL71327RC |Betagard MCB 32 A, 1 Pole, 15 kA, C Curve – Siemens

SKU: 5SL71327RC

Original price was: ₹680.00.Current price is: ₹312.80. Excl. GST

Out of stock

Out of stock

18 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Sourced through authorised channels, the Siemens 5SL71327RC miniature circuit breaker (mcb) delivers dependable performance for reliable circuit protection and isolation. Key ratings include 32 A, 1 Pole. myelectric.in stocks the 5SL71327RC |Betagard MCB 32 A, 1 Pole, 15 kA, C Curve for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.

📋 Technical Specifications

ParameterValue
BrandSiemens
Part Number / SKU5SL71327RC
CategoryMiniature Circuit Breaker (MCB)
Current Rating32 A
Poles1 Pole
Breaking Capacity15 kA
Tripping CurveCurve C
Rated Voltage230/400V AC
Rated Frequency50/60 Hz
Magnetic Trip Range5–10 × In (per IEC 60898-1)
Trip MechanismThermal-magnetic (bimetal overload + electromagnetic short-circuit)
Mounting35mm DIN rail (EN 60715)
Width18 mm (1 × 18mm modules)
Electrical Endurance≥ 20,000 operating cycles (per IEC 60898-1)
Pollution Degree3 (per IEC 60664-1)
StandardIS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial)
CertificationsBIS certified, CE, cULus (select models)

⚡ Key Features

  • Protects circuits at 32 A with 15 kA short-circuit breaking capacity — rated for industrial sub-distribution boards with high prospective fault currents.
  • Curve C tripping characteristic — optimised for general-purpose and inductive loads (motors, mixed circuits) — trips magnetically at 5–10× rated current.
  • 1 Pole — protects a single-phase final circuit; fits standard 35mm DIN rail in distribution boards.
  • Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
  • Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE, cULus (select models) — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Siemens product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

❓ Frequently Asked Questions

Q: What load can the 5SL71327RC protect at its rated 32 A?

A: The 5SL71327RC is rated to carry and protect circuits up to 32 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 32 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 15 kA breaking capacity on the 5SL71327RC mean in practice?

A: Breaking capacity (15 kA) is the maximum prospective short-circuit current the 5SL71327RC can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 15 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: Why is Curve C specified for the 5SL71327RC and what loads is it optimised for?

A: Curve C on the 5SL71327RC trips magnetically at 5–10× rated current, making it ideal for general-purpose circuits including fluorescent lamps, small motors, and mixed loads. Using the wrong curve can cause nuisance tripping (too sensitive) or inadequate protection (not sensitive enough). Always match the curve to the load’s inrush characteristics.

Q: What happens when the 5SL71327RC trips — how do I identify and reset it?

A: When the 5SL71327RC trips on fault, the handle moves to a midway position (between ON and OFF), distinctly visible from a distance. To reset: (1) identify and rectify the fault, (2) push the handle fully to OFF, (3) then switch back to ON. Never force-reset without investigating the fault cause.

Q: Is the 5SL71327RC suitable for both single-phase and three-phase systems?

A: The 5SL71327RC is a 1 pole device for single-phase circuits. For three-phase circuits, use a 3-pole or 4-pole MCB of the same series.