ABLS1A24038 | POWER SUPPLY 24V 3.8A 1PH OPTIMIZED - Schneider Electric
₹16,546.00 Original price was: ₹16,546.00.₹10,589.44Current price is: ₹10,589.44. Excl. GST
ABLS1A48100 | POWER SUPPLY 48V 10A 1PH OPTIMIZED - Schneider Electric
₹29,339.00 Original price was: ₹29,339.00.₹18,776.96Current price is: ₹18,776.96. Excl. GST
ABLS1A48050 | POWER SUPPLY 48V 5A 1PH OPTIMIZED – Schneider Electric
SKU:
ABLS1A48050
₹16,766.00 Original price was: ₹16,766.00.₹10,730.24Current price is: ₹10,730.24. Excl. GST
Dispatch By : 25 Weeks
Dispatch By : 25 Weeks
19
People watching this product now!
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included
Dedicated account manager
Technical support
Bulk & business pricing
3-day replacement
Specifications
| Main | |
|---|---|
| Range of product | Modicon Power Supply |
| Product or component type | Power supply |
| Power supply type | Regulated switch mode |
| Variant option | Optimized |
| Enclosure material | Metal |
| Nominal input voltage | 100…240 V AC single phase 100…240 V AC phase to phase 140…375 V DC |
| Rated power in W | 240 W |
| Output voltage | 48 V DC |
| Power supply output current | 5 A |
| Complementary | |
| Input voltage limits | 85…264 V AC 120…375 V DC |
| Nominal network frequency | 50…60 Hz |
| Network system compatibility | TN TT IT |
| Maximum leakage current | 1 mA 240 V AC |
| Input protection type | Integrated fuse (not interchangeable) 6.3 A External protection (recommended) 20 A External protection (recommended) 6 A |
| Inrush current | 30 A at 115 V 60 A at 230 V |
| Power factor | 0.95 at 115 V AC 0.95 at 230 V AC |
| Efficiency | 85 % at 115 V AC 88 % at 230 V AC |
| Output voltage adjustment | 44…54 V |
| Power dissipation in W | 36 W |
| Current consumption | < 2.8 A 115 V AC < 1.4 A 230 V AC < 2.4 A 140 V DC |
| Turn-on time | < 1 s |
| Holding time | > 20 ms 115 V AC > 20 ms 230 V AC |
| Startup with capacitive loads | 8000 µF |
| Residual ripple | 200 mV |
| Meantime between failure [MTBF] | at 25 °C, full load conforming to SR 332 |
| Output protection type | Against overload and short-circuits, protection technology: automatic reset Against over temperature, protection technology: manual reset Against overvoltage, protection technology: manual reset |
| Connections – terminals | Screw connection: 0.75…4 mm², (18 AWG…12 AWG) without wire end ferrule for output Screw connection: 0.75…4 mm², (18 AWG…12 AWG) with wire end ferrule for output Screw connection: 0.75…4 mm², (18 AWG…12 AWG) without wire end ferrule for input Screw connection: 0.75…4 mm², (18 AWG…12 AWG) with wire end ferrule for input |
| Line and load regulation | < 1.5 % at 0 to 100 % load at 25 °C < 0.5 % at full voltage range in line at 25 °C |
| Status LED | 1 LED (green) output voltage |
| Depth | 117.6 mm |
| Height | 123.6 mm |
| Width | 60 mm |
| Net weight | 0.8 kg |
| Output coupling | Single/parallel by switch |
| Marking | CE UKCA |
| Mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 Double-profile DIN rail |
| Supply | SELV conforming to IEC 60950-1 SELV conforming to IEC 60204-1 SELV conforming to IEC 60364-4-41 |
| Dielectric strength | 3000 V AC with input to output 2000 V AC with input to ground 1500 V AC with output to ground |
| Service life | 10 year(s) 40 °C 50 % load |
| Overvoltage category | II |
| Environment | |
| Standards | IEC 62368-1 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 CSA C22.2 No 62368-1 CSA C22.2 No 107.1 |
| Product certifications | CE CUL listed CUL recognized RCM CB Scheme EAC KC UKCA CURus |
| Operating altitude | < 5000 m overvoltage category II |
| Shock resistance | 150 m/s² for 11 ms |
| IP degree of protection | IP20 |
| Ambient air temperature for operation | -20…40 °C without derating mounting position A 115 V AC < 2000 m 40…70 °C with current derating mounting position A 115 V AC < 2000 m 40…70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 2000 m 50…70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 2000 m |
| Electrical shock protection class | Class I |
| Pollution degree | 2 |
| Vibration resistance | 3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6 10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6 |
| Electromagnetic immunity | Immunity to electrostatic discharge – test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 Immunity to electrostatic discharge – test level: 15 kV (air discharge) conforming to IEC 61000-4-2 Immunity to conducted RF disturbances – test level: 15 V/m (80 MHz…2 GHz) conforming to IEC 61000-4-3 Immunity to conducted RF disturbances – test level: 5 V/m (2…2.7 GHz) conforming to IEC 61000-4-3 Immunity to conducted RF disturbances – test level: 5 V/m (2.7…6 GHz) conforming to IEC 61000-4-3 Immunity to fast transients – test level: 4 kV (on input-output) conforming to IEC 61000-4-4 Surge immunity test – test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 Surge immunity test – test level: 3 kV (between phases) conforming to IEC 61000-4-5 Immunity to conducted RF disturbances – test level: 15 V (0.15…80 MHz) conforming to IEC 61000-4-6 Immunity to magnetic fields – test level: 30 A/m (50…60 Hz) conforming to IEC 61000-4-8 Immunity to voltage dips conforming to IEC 61000-4-11 Disturbing field emission conforming to EN 55016-2-3 Limits for harmonic current emissions conforming to IEC 61000-3-2 conforming to EN 55016-1-2 conforming to EN 55016-2-1 |
| Electromagnetic emission | Conducted emissions conforming to IEC 61000-6-3 Radiated emissions conforming to IEC 61000-6-4 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.000 cm |
| Package 1 Width | 17.500 cm |
| Package 1 Length | 18.000 cm |
| Package 1 Weight | 994.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 9.592 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
Customer Reviews
Related Products
XB5AR31N | Push button, Harmony XB5N XB7N, plastic, mushroom, green, 60mm, spring return, unmarked, 1 NO – Schneider Electric
SKU:
XB5AR31N
ZB2BW36C | Ø 22 mm fixing hole – push button head with blue lamp – Schneider Electric
SKU:
ZB2BW36C
MS13MD09 | 7MDL, 1HP 3 PHASE DOL STARTER – Schneider Electric
SKU:
MS13MD09
30002572 | EM1200 Energy meter Cl 0.5 RS485 LCD – Schneider Electric
SKU:
30002572