ATH230U07M3 | ATH230 0.75kW/1HP 200/240V 3PH IP20 - Schneider Electric
ATH230U07M3 | ATH230 0.75kW/1HP 200/240V 3PH IP20 - Schneider Electric Original price was: ₹64,192.00.Current price is: ₹23,109.12. Excl. GST
Back to products
ATH230U11M2 | ATH230 1.1kW/1.5HP 200/240V 1PH IP20 - Schneider Electric
ATH230U11M2 | ATH230 1.1kW/1.5HP 200/240V 1PH IP20 - Schneider Electric Original price was: ₹45,500.00.Current price is: ₹16,380.00. Excl. GST

ATH230U07N4 | ATH230 0.75kW/1HP 380/500V 3PH IP20 – Schneider Electric

SKU: ATH230U07N4

Original price was: ₹44,270.00.Current price is: ₹15,937.20. Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

18 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
Range of productAltivar HVAC ATH200
Product specific applicationHVAC
Product or component typeVariable speed drive
VariantStandard version
Device short nameATH230
Product destinationAsynchronous motors
Synchronous motors
Mounting modeCabinet mount
IP degree of protectionIP20
Network number of phases3 phases
[Us] rated supply voltage380…500 V – 15…10 %
Relative symmetric mains voltage tolerance10 %
Supply frequency50…60 Hz – 5…5 %
Relative symmetric network frequency tolerance5 %
nominal output current2.3 A
Maximum transient current2.6 A
Motor power kW0.75 kW
Motor power hp1.0 hp
Safety functionSTO (safe torque off)
Safety levelSIL 3 conforming to IEC 61508
PL = e conforming to ISO 13849-1
EMC filterClass C2 EMC filter integrated
Communication port protocolModbus serial
BACnet MS/TP
Option cardCommunication module for BACnet IP
Complementary
Apparent power2.4 kVA at 500 V
Power dissipation in W32 W
Discrete input number7
Discrete input typeSTO safe torque off, 24 V DC, impedance: 1.5 kOhm
DI1…DI6 logic inputs, 24 V DC (30 V)
DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
Discrete input logicPositive logic (source)
Negative logic (sink)
[Us] rated supply voltage24 V for DC
Discrete output number1
Discrete output typeOpen collector DQ+ 0…1 kHz 30 V DC 100 mA
Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number3
Analogue input typeAI1 voltage: 0…10 V DC, impedance: 30 kOhm, resolution 10 bits
AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits
AI3 current: 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
Analogue output number1
Analogue output typeSoftware-configurable current AQ1: 0…20 mA impedance 800 Ohm, resolution 10 bits
Software-configurable voltage AQ1: 0…10 V DC impedance 470 Ohm, resolution 10 bits
Relay output number2
Relay output typeConfigurable relay logic R1A 1 NO electrical durability 100000 cycles
Configurable relay logic R1B 1 NC electrical durability 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO electrical durability 100000 cycles
Configurable relay logic R2C
Maximum switching currentRelay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Minimum switching currentRelay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
Physical interface2-wire RS 485
Connector typeRJ45
Method of accessServer Modbus serial
Subordinate BACnet MS/TP
Transmission rate4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
9.6, 19.2, 38.4, 76.8 kbit/s
Transmission frameRTU
MS/TP
Number of addresses0…247
0…127
Data format8 bits, configurable odd, even or no parity 1or 2 stop
Type of polarizationNo impedance
Line current3.8 A at 380 V
2.6 A at 500 V
Prospective line Isc5 kA
Output frequency0.599 kHz
Output voltage<= power supply voltage
Switching frequency2…16 kHz adjustable
4…16 kHz with derating
nominal switching frequency4 kHz
4 quadrant operation possibleTrue
Asynchronous motor control profileVoltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio – Energy Saving, quadratic U/f
Flux vector control without sensor – Energy Saving
Voltage/frequency ratio, 2 points
Synchronous motor control profileVector control without sensor
Acceleration and deceleration rampsLinear
U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
Motor slip compensationAutomatic whatever the load
Adjustable 0…300 %
Not available in voltage/frequency ratio (2 or 5 points)
Braking to standstillBy DC injection
Brake chopper integratedTrue
StandardsIEC 61800-5-1
IEC 61800-3
UL 508C
IEC 61800-3 environment 1 category C2
IEC 61800-3 environments 2 category C3
IEC 60721-3
IEC 61508
IEC 13849-1
Product certificationsCULus
CE
UKCA
EAC
ATEX
KC
RCM
MarkingCULus
CE
UKCA
KC
EAC
ATEX
RCM
With safety function Safe torque off (STO)True
Protection typeLine supply phase loss: drive
Motor phase loss: motor
Line supply overvoltage and undervoltage: drive
Overheating protection: drive
Overload: motor
With PTC probes: motor
Short-circuit between motor phases: drive
Overcurrent between output phases and earth: drive
Width105 mm
Height142 mm
Depth158 mm
Net weight1.2 kg
Function availableFire mode
Run permissive
PID controller
Additional PID
Damper control
Underload detection for broken belt
Environment
Pollution degree2
Operating altitude<= 1000 m without derating
1000…3000 m with current derating 1 % per 100 m
Operating positionVertical +/- 10 degree
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13…200 Hz
Relative humidity5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Volume of cooling air18 m3/h
Overvoltage categoryIII
Noise level51 dB
Ambient air transport temperature-25…70 °C
Ambient air temperature for operation-10…50 °C without derating
50…60 °C with derating factor
Ambient air temperature for storage-25…70 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height18.000 cm
Package 1 Width18.500 cm
Package 1 Length18.500 cm
Package 1 Weight1.688 kg
Unit Type of Package 2P06
Number of Units in Package 230
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight60.700 kg
Contractual warranty
Warranty (in months)18

Customer Reviews