ATH230U75S6 | ATH230 7.5kW/10HP 525/600V 3PH IP20 - Schneider Electric
₹141,770.00 Original price was: ₹141,770.00.₹51,037.20Current price is: ₹51,037.20. Excl. GST
ATH630C13N4Z | ATH630 132kW 200HP 380/480V WO KEYPAD - Schneider Electric
₹598,156.00 Original price was: ₹598,156.00.₹334,967.36Current price is: ₹334,967.36. Excl. GST
ATH630C11N4Z | ATH630 110kW 150HP 380/480V WO KEYPAD – Schneider Electric
SKU:
ATH630C11N4Z
₹549,145.00 Original price was: ₹549,145.00.₹307,521.20Current price is: ₹307,521.20. Excl. GST
Dispatch By : 6 Weeks
Dispatch By : 6 Weeks
11
People watching this product now!
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included
Dedicated account manager
Technical support
Bulk & business pricing
3-day replacement
Specifications
| Main | |
|---|---|
| Range of product | Altivar HVAC ATH600 |
| Product specific application | HVAC |
| Product or component type | Variable speed drive |
| Variant | Standard version |
| Device short name | ATH630 |
| Product destination | Asynchronous motors Synchronous motors |
| Mounting mode | Cabinet mount |
| IP degree of protection | IP00 |
| Network number of phases | 3 phases |
| [Us] rated supply voltage | 380…480 V – 15…10 % |
| Relative symmetric mains voltage tolerance | 10 % |
| Supply frequency | 50…60 Hz – 5…5 % |
| Relative symmetric network frequency tolerance | 5 % |
| nominal output current | 211 A at 380 V (normal duty) 211 A at 480 V (normal duty) 173 A at 380 V (heavy duty) 173 A at 480 V (heavy duty) |
| Maximum transient current | 232.1 A during 60 s (normal duty) 259.5 A during 60 s (heavy duty) |
| Motor power kW | 110 kW for normal duty 90 kW for heavy duty |
| Motor power hp | 150 hp for normal duty 125 hp for heavy duty |
| Line current | 201 A at 380 V (normal duty) 165 A at 480 V (normal duty) 170 A at 380 V (heavy duty) 143 A at 480 V (heavy duty) |
| EMC filter | Class C3 EMC filter integrated |
| Safety function | STO (safe torque off) |
| Safety level | SIL 3 conforming to IEC 61508 PL = e conforming to ISO 13849-1 |
| Cybersecurity function | True |
| Cybersecurity level and standard | Security level (SL) 1 conforming to IEC 62443-4-2 |
| Communication port protocol | Modbus serial BACnet MS/TP |
| Option card | Communication module for BACnet IP Communication module for PROFINET Communication module for Ethernet IP/Modbus TCP Digital and analog I/O extension module Output relay extension module |
| Complementary | |
| Discrete input number | 8 |
| Discrete input type | STOA, STOB safety input, 24 V DC DI1…DI6 digital input, 24 V DC, impedance: 4.4 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC |
| Discrete input logic | Positive logic (source) (DI1…DI6), <= 5 V (state 0), >= 11 V (state 1) Positive logic (source) (STOA, STOB), <= 5 V (state 0), >= 11 V (state 1) Negative logic (sink) (DI1…DI6), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1) |
| Input compatibility | DI1…DI6: discrete input level 1 PLC conforming to IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
| Supply | External supply for control circuit: 24 V DC (19…30 V), <800 mA, protection type: overload and short-circuit protection Internal supply for digital inputs and STO: 24 V DC (20.4…27 V), <200 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer: 10.5 V DC +/- 5 %, <10 mA, protection type: short-circuit |
| Analogue input number | 3 |
| Analogue input type | AI1: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI2: 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 12 bits AI3: 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 12 bits AI2, AI3 PTC/PT 100/PT 1000/KTY84 temperature probe |
| Analogue output number | 2 |
| Analogue output type | Software-configurable voltage AQ1, AQ2: 0…10 V impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits |
| Accuracy | +/- 1.5 % (AI1, AI2, AI3) for a temperature variation 60 °C +/- 1 % (AQ1, AQ2) for a temperature variation 60 °C |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output |
| Relay output number | 3 |
| Relay output type | Relay outputs R1A, R1B, R1C: 1 NO 1 NC electrical durability 100000 cycles Relay outputs R2A, R2C: 1 NO electrical durability 100000 cycles Relay outputs R3A, R3C: 1 NO electrical durability 100000 cycles |
| Sampling duration | 2 ms + 0…0.5 ms DI1…DI6 digital input 5 ms + 0…1 ms DI5, DI6 pulse input 5 ms + 0…1 ms AI1, AI2, AI3 10 ms + 0…1 ms AQ1, AQ2 5 ms +/- 0.5 ms R1, R2, R3 |
| Maximum switching current | Relay output R1, R2, R3 on resistive load load: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load load: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load load, cos phi = 0.4 and L/R = 0.7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load load, cos phi = 0.4 and L/R = 0.7 ms: 2 A at 30 V DC |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Physical interface | 2-wire RS 485 |
| Connector type | RJ45 and open style terminals |
| Method of access | Server Modbus RTU Subordinate BACnet MS/TP |
| Transmission rate | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps 9.6, 19.2, 38.4, 76.8 kbit/s |
| Transmission frame | RTU MS/TP |
| Number of addresses | 1…247 1…127 |
| Data format | 8 bits, configurable odd, even or no parity 8 bits, no parity, 1 stop |
| Type of polarization | 120 ohm termination or no impedance |
| Prospective line Isc | 50 kA |
| Output frequency | 0.5 kHz |
| Output voltage | <= power supply voltage |
| 4 quadrant operation possible | False |
| Asynchronous motor control profile | Voltage/frequency ratio, 5 points Flux vector control with sensor, standard Voltage/frequency ratio – Energy Saving, quadratic U/f Flux vector control without sensor – Energy Saving Voltage/frequency ratio, 2 points |
| Synchronous motor control profile | Vector control without sensor |
| Acceleration and deceleration ramps | Acceleration/deceleration ramp adaptation Linear S, U or customized |
| Motor slip compensation | Adjustable Automatic whatever the load Can be suppressed Not available with synchronous motors |
| Switching frequency | 2…8 kHz adjustable with derating factor |
| Nominal switching frequency | 2.5 kHz |
| Braking to standstill | By DC injection |
| Brake chopper integrated | False |
| Apparent power | 137.2 kVA (normal duty) 118.9 kVA (heavy duty) |
| power loss static current independent | 67 W |
| Power dissipation in W | AF (air forced): 2318 W, switching frequency 2.5 kHz (normal duty) AN (air natural): 320 W, switching frequency 2.5 kHz (normal duty) AF (air forced): 1795 W, switching frequency 2.5 kHz (heavy duty) AN (air natural): 292 W, switching frequency 2.5 kHz (heavy duty) |
| Standards | UL 61800-5-1 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 RoHS |
| Product certifications | CE UKCA UL CULus EAC RCM KCC ATEX |
| Marking | CE UKCA CULus EAC RCM ATEX WEEE ROHS KCC |
| With safety function Safe torque off (STO) | True |
| Protection type | Thermal overload protection: motor Safe torque off: motor Motor phase loss: motor Against exceeding limit speed: motor Temperature protection: drive Overheating: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Break on the control circuit: drive |
| Width | 316.6 mm |
| Height | 852 mm |
| Depth | 390 mm |
| Net weight | 82 kg |
| Function available | Fire mode Forced fire mode Run permissive PID controller 3 additional PID Damper control Underload detection for broken belt Scroll compressor management Skipped frequencies Catch on the fly Power monitoring Cybersecure firmware update |
| Environment | |
| Operating altitude | 1000 m without derating 1000…3000 m with current derating 1 % per 100 m |
| Operating position | Vertical position |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3 Class 3B1 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 15 gn at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 1 gn at 13…200 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Volume of cooling air | 600 m3/h |
| Noise level | 69.9 dB |
| Pollution degree | 2 |
| Ambient air temperature for operation | -15…50 °C without derating 50…60 °C with derating factor |
| Ambient air temperature for storage | -40…70 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 66 cm |
| Package 1 Width | 47.5 cm |
| Package 1 Length | 103 cm |
| Package 1 Weight | 88.6 kg |
Customer Reviews
Related Products
XB5AR31N | Push button, Harmony XB5N XB7N, plastic, mushroom, green, 60mm, spring return, unmarked, 1 NO – Schneider Electric
SKU:
XB5AR31N
ZB2BW36C | Ø 22 mm fixing hole – push button head with blue lamp – Schneider Electric
SKU:
ZB2BW36C
MS13MD09 | 7MDL, 1HP 3 PHASE DOL STARTER – Schneider Electric
SKU:
MS13MD09
30002572 | EM1200 Energy meter Cl 0.5 RS485 LCD – Schneider Electric
SKU:
30002572