ATV212HD18N4 Atv212 18,5Kw 25Hp 480V Tri Cem Ip20 Schneider Electric atv212hd18n4
ATV212HD18N4 | Atv212 18,5Kw 25Hp 480V Tri Cem Ip20 - Schneider Electric Original price was: ₹229,956.00.Current price is: ₹82,784.16. Excl. GST
Back to products
MM1102 1 Mm 2 Gang GI Metal Box Schneider Electric product placeholder
ATV930U22N4 | Atv930 Ip21 2,2Kw 400V/480V Variable Spe - Schneider Electric Original price was: ₹228,446.00.Current price is: ₹70,818.26. Excl. GST

ATS480D88Y | Soft starter ATS480 88A 208 to 690V – Schneider Electric

SKU: ATS480D88Y

Original price was: ₹189,066.00.Current price is: ₹70,899.75. Excl. GST

Dispatch By : 2 Weeks

Dispatch By : 2 Weeks

12 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Schneider Electric ATS480D88Y is a soft starter from the Altivar Soft Starter ATS480 range, engineered for motor control and switching in demanding Indian and international installations. Key ratings include Normal duty: 88.0 A, 208–690V AC, IP20. Buy the ATS480D88Y | Soft starter ATS480 88A 208 to 690V online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUATS480D88Y
CategorySoft Starter
Main
Range of productAltivar Soft Starter ATS480
Product or component typeSoft starter
Product destinationAsynchronous motors
Product specific applicationProcess and infrastructures
Device short nameATS480
Network number of phases3 phases
Utilisation categoryAC-3A
AC-53A
Ue power supply voltage208…690 V – 15…10 %
power supply frequency50…60 Hz – 20…20 %
[Ie] rated operational currentNormal duty: 88.0 A (at <40 °C)
rated current in heavy duty75.0 A at 40 °C for heavy duty
Torque controlTrue
IP degree of protectionIP20
Motor power kW22.0 kW at 230 V in the motor supply line normal duty
18.5 kW at 230 V in the motor supply line heavy duty
45.0 kW at 400 V in the motor supply line normal duty
37.0 kW at 400 V in the motor supply line heavy duty
45.0 kW at 440 V in the motor supply line normal duty
37.0 kW at 440 V in the motor supply line heavy duty
55.0 kW at 500 V in the motor supply line normal duty
45.0 kW at 500 V in the motor supply line heavy duty
55.0 kW at 525 V in the motor supply line normal duty
45.0 kW at 525 V in the motor supply line heavy duty
75.0 kW at 660 V in the motor supply line normal duty
55.0 kW at 660 V in the motor supply line heavy duty
75.0 kW at 690 V in the motor supply line normal duty
55.0 kW at 690 V in the motor supply line heavy duty
45.0 kW at 230 V to the motor delta terminals normal duty
37.0 kW at 230 V to the motor delta terminals heavy duty
75.0 kW at 400 V to the motor delta terminals normal duty
55.0 kW at 400 V to the motor delta terminals heavy duty
Motor power hp25.0 hp at 208 V normal duty
20.0 hp at 208 V heavy duty
30.0 hp at 230 V normal duty
25.0 hp at 230 V heavy duty
60.0 hp at 460 V normal duty
50.0 hp at 460 V heavy duty
75.0 hp at 575 V normal duty
60.0 hp at 575 V heavy duty
Option cardCommunication module for Profibus DP V1
Communication module for Modbus TCP/EtherNet/IP
Communication module for CANopen daisy chain
Communication module for CANopen Sub-D
Communication module for CANopen open style
Communication module for PROFINET
Complementary
Device connectionIn the motor supply line
To the motor delta terminals
[Us] control circuit voltage110…230 V AC 50/60 Hz – 15…10 %
Apparent power0.09 kVA
Integrated motor overload protectionTrue
motor thermal protection classClass 10E
Protection typePhase failure: line
Integrated thermal protection: motor
Thermal protection: starter
Current overload: motor
Underload: motor
Excessive starting time, locked rotor: motor
Motor phase loss: motor
Line supply phase loss: line
Line supply phase loss: motor
Thermal protection: motor
current limiting %In (5 x Ie maximum)150…700 %
Rated current pwr loss specification88.0 A
Power loss static current independent25.0 W
Power loss per device current dependent270.0 W
StandardsIEC 60947-4-2
UL 60947-4-2
IEC 60664-1
Product certificationsCE
cULus
CCC
UKCA
RCM
EAC
DNV
ABS
BV
CCS
MarkingCE
CCC
UKCA
EAC
RCM
CULus
[Uc] control circuit voltage24 V DC
Discrete input number4
Discrete input type(STOP) logic inputs, 3500 Ohm
(RUN) logic inputs, 3500 Ohm
(DI3) programmable as logic input, 3500 Ohm
(DI4) programmable as logic input, 3500 Ohm
Input compatibilitySTOP: discrete input level 1 PLC conforming to IEC 61131-2
RUN: discrete input level 1 PLC conforming to IEC 61131-2
DI3: discrete input level 1 PLC conforming to IEC 61131-2
DI4: discrete input level 1 PLC conforming to IEC 61131-2
Discrete input logicProgrammable digital input at State 0: < 5 V
Relay output number3
Relay output typeRelay outputs R1A 1 NO
Relay outputs R1B 1 NO
Relay outputs RIC NO/NC programmable
Minimum switching current100 mA at 12 V DC for relay outputs
Maximum switching currentRelay outputs 2 A at 250 V AC
Relay outputs 2 A at 30 V DC
Relay outputs
Discrete output number2
Discrete output type(DQ1) programmable digital output <= 30 V
(DQ2) programmable digital output <= 30 V
Output compatibilityOpen collector level 1 PLC conforming to IEC 65A-68
Analogue input number1
Analogue input typeAI1/PTC PTC/Pt 100 temperature probe
PTC2 PTC/Pt 100 temperature probe
PTC3 PTC/Pt 100 temperature probe
Analogue output number1
Analogue output typeCurrent output AQ1: 0…20 mA or 0…10 V, impedance <500 Ohm
Communication port protocolModbus serial
Connector type1 RJ45
Communication data linkSerial
Physical interface2-wire RS 485
Transmission rate1200…256000 bit/s
Transmission frameRTU
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance for Modbus serial
Number of addresses0…227 for Modbus serial
Method of accessSlave Modbus serial
Function availableExternal bypass control
Pre-heating
Smoke extraction
Multi-motor cascade
Second motor set
User management
Ports and services hardening
Security event logging
Cybersecure firmware update
Single direction
Display screen availableTrue
Operating positionVertical +/- 10 degree
Height290.0 mm
Width190.0 mm
Depth247.0 mm
Product weight8.3 kg
Environment
Electromagnetic compatibilityConducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions with bypass level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-11
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Pollution degreeLevel 3
[Uimp] rated impulse withstand voltage6 kV
[Ui] rated insulation voltage690 V
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Relative humidity0…95 % without condensation or dripping water conforming to IEC 60068-2-3
Ambient air temperature for operation40…60 °C (with current derating of 2 % per °C)
-15…40 °C (without derating)
Ambient air temperature for storage-25…70 °C
Operating altitude<= 1000 m without derating
> 1000…4000 m with current derating 1 % per 100 m
Maximum deflection under vibratory load (during operation)1.5 mm at 2…13 Hz
Maximum deflection under vibratory load (during storage)1.75 mm at 2…9 Hz
Maximum deflection under vibratory load (during transport)1.75 mm at 2…9 Hz
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13…200 Hz
Maximum acceleration under vibratory load (during storage)15 m/s² at 200…500 Hz
10 m/s² at 9…200 Hz
Maximum acceleration under vibratory load (during transport)15 m/s² at 200…500 Hz
10 m/s² at 9…200 Hz
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under shock load (during storage)100 m/s² at 11 ms
Maximum acceleration under shock load (during transport)100 m/s² at 11 ms
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height37.000 cm
Package 1 Width31.000 cm
Package 1 Length39.000 cm
Package 1 Weight9.785 kg
Unit Type of Package 2P06
Number of Units in Package 28
Package 2 Height86.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight86.500 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 88 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
  • 208–690V AC operating voltage — compatible with standard LV distribution voltages used in Indian industrial installations.
  • Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

VW3A3720VW3A3607VW3A3628VW3A3608VW3A3618VW3A1111VW3A1112VW3A1114VW3A1104R10VW3A1104R30VW3A1104R50VW3A1104R100VW3A1105VZ3V482

❓ Frequently Asked Questions

Q: What is the significance of the 88 A rating on the ATS480D88Y?

A: The 88 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.