TM251MESC CONTROLLER M251-Ethernet CAN Schneider Electric pf130201 web
TM251MESC | CONTROLLER M251-Ethernet+CAN - Schneider Electric Original price was: ₹101,309.00.Current price is: ₹51,667.59. Excl. GST
Back to products
C25F36E250 NSX250F 36kA AC 3P3D 250A 6.2E Schneider Electric c25f36e250
C25F36E250 | NSX250F 36kA AC 3P3D 250A 6.2E - Schneider Electric Original price was: ₹144,320.00.Current price is: ₹69,273.60. Excl. GST

ATV12HU40M3 | Variable speed drive ATV12 – 4kW – 5hp – 200..240V – 3ph – with heat sink – Schneider Electric

SKU: ATV12HU40M3

Original price was: ₹115,539.00.Current price is: ₹41,594.04. Excl. GST

Dispatch By : 11 Weeks

Dispatch By : 11 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: ATV12HU40M3

Same-day dispatch · GST invoice available

10 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Schneider Electric ATV12HU40M3 is a variable frequency drive (vfd) from the Altivar 12 range, engineered for variable-speed motor control and energy savings in demanding Indian and international installations. Key ratings include IP20. Buy the ATV12HU40M3 | Variable speed drive ATV12 – 4kW – 5hp – 200..240V – 3ph – with heat sink online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUATV12HU40M3
CategoryVariable Frequency Drive (VFD)
Main
Range of productAltivar 12
Product or component typeVariable speed drive
Product specific applicationSimple machine
Mounting modeCabinet mount
Communication port protocolModbus
Supply frequency50/60 Hz +/- 5 %
[Us] rated supply voltage200…240 V – 15…10 %
nominal output current16.7 A
Motor power kW4 kW
Motor power hp5 hp
EMC filterWithout EMC filter
IP degree of protectionIP20
Motor power hp5 hp
Complementary
Discrete input number4
Discrete output number2
Analogue input number1
Analogue output number1
Relay output number1
Physical interface2-wire RS 485
Connector type1 RJ45
Continuous output current16.7 A at 4 kHz
Method of accessServer Modbus serial
Speed drive output frequency0.5…400 Hz
Speed range1…20
Sampling duration20 ms, tolerance +/- 1 ms for logic input
10 ms for analogue input
Linearity error+/- 0.3 % of maximum value for analogue input
Frequency resolutionAnalog input: converter A/D, 10 bits
Display unit: 0.1 Hz
Time constant20 ms +/- 1 ms for reference change
Transmission rate9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
Transmission frameRTU
Number of addresses1…247
Data format8 bits, configurable odd, even or no parity
Communication serviceRead holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)
Type of polarizationNo impedance
4 quadrant operation possibleFalse
Asynchronous motor control profileQuadratic voltage/frequency ratio
Voltage/frequency ratio (V/f)
Sensorless flux vector control
Maximum output frequency4 kHz
Transient overtorque150…170 % of nominal motor torque depending on drive rating and type of motor
Acceleration and deceleration rampsS
U
Linear from 0 to 999.9 s
Motor slip compensationPreset in factory
Adjustable
Switching frequency2…16 kHz adjustable
4…16 kHz with derating factor
Nominal switching frequency4 kHz
Braking to standstillBy DC injection
Brake chopper integratedFalse
Line current23.8 A at 100 V (heavy duty)
19.9 A at 120 V (heavy duty)
Maximum input current19.9 A
Maximum output voltage240 V
Apparent power8.3 kVA at 240 V (heavy duty)
Maximum transient current25.0 A during 60 s (heavy duty)
27.6 A during 2 s (heavy duty)
Network frequency50…60 Hz
Relative symmetric network frequency tolerance5 %
Prospective line Isc5 kA
Base load current at high overload16.7 A
Power dissipation in WForced cooling: 128.0 W
With safety function Safely Limited Speed (SLS)False
With safety function Safe brake management (SBC/SBT)False
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)False
With sft fct Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)False
With safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Protection typeLine supply overvoltage
Line supply undervoltage
Overcurrent between output phases and earth
Overheating protection
Short-circuit between motor phases
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²t
tightening torque1.2 N.m
InsulationElectrical between power and control
Quantity per setSet of 1
Width140 mm
Height184 mm
Depth141.2 mm
Product weight2 kg
Environment
Operating altitude<= 1000 m without derating
> 1000…3000 m with current derating 1 % per 100 m
Operating positionVertical +/- 10 degree
Product certificationsNOM
CSA
C-Tick
UL
GOST
RCM
KC
MarkingCE
StandardsUL 508C
UL 618000-5-1
IEC 61800-5-1
IEC 61800-3
Assembly styleWith heat sink
Electromagnetic compatibilityElectrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Immunity to conducted disturbances level 3 conforming to IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Surge immunity test level 3 conforming to IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13…200 Hz
Maximum deflection under vibratory load (during operation)1.5 mm at 2…13 Hz
Volume of cooling air16.4 m3/h
Overvoltage categoryClass III
Regulation loopAdjustable PID regulator
Electromagnetic emissionRadiated emissions environment 1 category C2 conforming to IEC 61800-3 2…16 kHz shielded motor cable
Conducted emissions conforming to IEC 61800-3
Vibration resistance1 gn (f = 13…200 Hz) conforming to IEC 60068-2-6
1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to IEC 60068-2-6
Shock resistance15 gn conforming to IEC 60068-2-27 for 11 ms
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Noise level50 dB
Pollution degree2
Ambient air transport temperature-25…70 °C
Ambient air temperature for operation-10…50 °C without derating
50…60 °C with current derating 2.2 % per °C
Ambient air temperature for storage-25…70 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height25.000 cm
Package 1 Width19.500 cm
Package 1 Length26.800 cm
Package 1 Weight2.444 kg
Unit Type of Package 2S06
Number of Units in Package 212
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight42.328 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • Rated for a 4 kW motor — adjustable output frequency from near 0 to 50/60 Hz gives stepless speed control for pumps, fans, compressors, and conveyor drives.
  • Input supply 200–240V AC — no transformer required for standard Indian 415V three-phase mains supply.
  • Soft-start acceleration ramp — limits motor starting current to ~1.5× FLC vs. the 6–7× FLC of DOL starting; eliminates mechanical shock on gearboxes, belts, and couplings and reduces peak demand charges.
  • Built-in electronic motor protection — overload, phase-loss, overvoltage (240V AC+10%), undervoltage, and short-circuit protection without additional external relays.
  • Manufactured to IEC 61800-5-1 (safety) and IEC 61800-3 (EMC) — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

VW3A4554

❓ Frequently Asked Questions

Q: Can the ATV12HU40M3 be used to control a 4 kW motor with soft start and variable speed?

A: Yes. This VFD is rated for a 4 kW motor load and provides stepless speed control from 0 to rated frequency (typically 0–50 Hz). The soft-start ramp eliminates mechanical shock and reduces starting current from typically 6–7× FLC to just 1–1.5× FLC. Ensure the motor cable length does not exceed the VFD manufacturer’s maximum (typically 50–100m without output filter) to avoid insulation stress.

Q: Does the ATV12HU40M3 require an input line reactor or output filter for protection?

A: For installations with poor power quality (voltage spikes, harmonics), an input line reactor (3–5% impedance) extends the ATV12HU40M3’s life by reducing diode stress and lowering harmonic injection. An output dV/dt filter is recommended when motor cable exceeds 50m to prevent reflected wave damage to motor insulation, especially on older motors not rated for VFD use.

Q: Can the ATV12HU40M3 run a standard squirrel-cage induction motor without modification?

A: Yes — standard squirrel-cage induction motors rated for 415V 50Hz can be driven by this VFD. However, at low speeds (<20 Hz), motor cooling is reduced because the shaft-mounted fan slows down. For extended low-speed operation, fit a separately powered external cooling fan on the motor, or use a motor specified for inverter duty.

Q: Does the ATV12HU40M3 inject harmonics into the supply and is a line reactor required?

A: VFDs including the ATV12HU40M3 generate harmonic currents (primarily 5th and 7th order) due to their diode rectifier front-end. In installations where total harmonic distortion (THD) is a concern — such as facilities with sensitive medical or measurement equipment, or where multiple large drives share a common bus — a 3% or 5% impedance line reactor on the input significantly reduces harmonic injection and protects the drive’s DC bus capacitors from voltage spikes. Check if your site’s power quality specification sets a THD limit.

Customer Reviews