ATV610C25N4 | ATV610, 250 kW 400HP, 380-460 V, IP00 - Schneider Electric
₹1,762,353.00 Original price was: ₹1,762,353.00.₹528,705.90Current price is: ₹528,705.90. Excl. GST
ATV630D11N4Z | ATV630 IP20 11KW 400V WO KEYPAD - Schneider Electric
₹260,793.00 Original price was: ₹260,793.00.₹80,845.83Current price is: ₹80,845.83. Excl. GST
ATV610C31N4 | ATV610, 315 kW/500HP, 380/460 V, IP00 – Schneider Electric
SKU:
ATV610C31N4
₹2,044,509.00 Original price was: ₹2,044,509.00.₹613,352.70Current price is: ₹613,352.70. Excl. GST
Dispatch By : 13 Weeks
Dispatch By : 13 Weeks
20
People watching this product now!
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included
Dedicated account manager
Technical support
Bulk & business pricing
3-day replacement
Specifications
| Main | |
|---|---|
| Range of product | Altivar ATV610 |
| Product specific application | Fan, pump, compressor, conveyor |
| Product or component type | Variable speed drive |
| Device short name | ATV610 |
| Variant | Standard version |
| Product destination | Asynchronous motors |
| Mounting mode | Cabinet mount |
| EMC filter | Integrated conforming to IEC 61800-3 category C3 with 50 m |
| IP degree of protection | IP00 |
| Type of cooling | Forced convection |
| Supply frequency | 50…60 Hz +/-5 % |
| Network number of phases | 3 phases |
| [Us] rated supply voltage | 380…460 V – 15…10 % |
| Motor power kW | 315 kW for normal duty 250 kW for heavy duty |
| Motor power hp | 500 hp for normal duty 400 hp for heavy duty |
| Line current | 571 A at 380 V (normal duty) 481 A at 460 V (normal duty) 460 A at 380 V (heavy duty) 391 A at 460 V (heavy duty) |
| Prospective line Isc | 50 kA |
| Apparent power | 383 kVA at 460 V (normal duty) 311 kVA at 460 V (heavy duty) |
| Continuous output current | 616 A at 2.5 kHz for normal duty 481 A at 2.5 kHz for heavy duty |
| Maximum transient current | 678 A during 60 s (normal duty) 722 A during 60 s (heavy duty) |
| Asynchronous motor control profile | Variable torque standard Optimized torque mode |
| Output frequency | 0.1…500 Hz |
| Nominal switching frequency | 2.5 kHz |
| Switching frequency | 2…8 kHz adjustable |
| number of preset speeds | 16 preset speeds |
| Communication port protocol | Modbus serial |
| Option card | Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card |
| Complementary | |
| Output voltage | <= power supply voltage |
| Motor slip compensation | Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 s S, U or customized |
| Braking to standstill | By DC injection |
| Protection type | Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive |
| Frequency resolution | Display unit: 0.1 Hz Analog input: 0.012/50 Hz |
| Electrical connection | Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 240 mm² Motor, screw terminal: 2 x 240 mm² |
| Connector type | 1 RJ45 (on the remote graphic terminal) for Modbus serial |
| Physical interface | 2-wire RS 485 for Modbus serial |
| Transmission frame | RTU for Modbus serial |
| Transmission rate | 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
| Type of polarization | No impedance for Modbus serial |
| Number of addresses | 1…247 for Modbus serial |
| Method of access | Slave |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
| Local signalling | 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage |
| Width | 595 mm |
| Depth | 380 mm |
| Net weight | 180 kg |
| Analogue input number | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor |
| Discrete input number | 6 |
| Discrete input type | DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
| Input compatibility | DI1…DI6: logic input level 1 PLC conforming to IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68 |
| Discrete input logic | Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) |
| Analogue output number | 2 |
| Analogue output type | Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits |
| Sampling duration | 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Isolation | Between power and control terminals |
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
| Environment | |
| Noise level | 76 dB conforming to 86/188/EEC |
| Power dissipation in W | 5925 W(forced convection) at 380 V, switching frequency 2.5 kHz |
| Operating position | Vertical +/- 10 degree |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 6 gn for 11 ms conforming to IEC 60068-2-27 |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -10…40 °C (without derating) 40…60 °C (with derating factor) |
| Operating altitude | <= 1000 m without derating 1000…3000 m with current derating 1 % per 100 m |
| Environmental characteristic | Chemical pollution resistance class 3C2 conforming to IEC 60721-3-3 Dust pollution resistance class 3S2 conforming to IEC 60721-3-3 |
| Standards | IEC 61800-3 Environment 2 category C3 IEC 61800-3 IEC 61800-5-1 IEC 60721-3 |
| Marking | CE |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 62.5 cm |
| Package 1 Width | 76.1 cm |
| Package 1 Length | 141.2 cm |
| Package 1 Weight | 208 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
Customer Reviews
Related Products
XB5AR31N | Push button, Harmony XB5N XB7N, plastic, mushroom, green, 60mm, spring return, unmarked, 1 NO – Schneider Electric
SKU:
XB5AR31N
ZB2BW36C | Ø 22 mm fixing hole – push button head with blue lamp – Schneider Electric
SKU:
ZB2BW36C
MS13MD09 | 7MDL, 1HP 3 PHASE DOL STARTER – Schneider Electric
SKU:
MS13MD09
30002572 | EM1200 Energy meter Cl 0.5 RS485 LCD – Schneider Electric
SKU:
30002572














