VX5A1203 Atv61,Atv71Gate Drive Pcba Schneider Electric Image
VX5A1203 | Atv61,Atv71Gate Drive Pcba - Schneider Electric Original price was: ₹474,703.00.Current price is: ₹408,244.58. Excl. GST
Back to products

ATV630U22N4 | Variable Speed Drive Ip21 2,2Kw 400V/480 – Schneider Electric

SKU: ATV630U22N4

Original price was: ₹187,951.00.Current price is: ₹58,264.81. Excl. GST

Dispatch By : 2 Weeks

Dispatch By : 2 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: ATV630U22N4

Same-day dispatch · GST invoice available

18 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The Schneider Electric ATV630U22N4 is a variable frequency drive (vfd) from the Altivar Process ATV600 range, engineered for variable-speed motor control and energy savings in demanding Indian and international installations. Key ratings include 400V AC, IP21. Buy the ATV630U22N4 | Variable Speed Drive Ip21 2,2Kw 400V/480 online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUATV630U22N4
CategoryVariable Frequency Drive (VFD)
Main
Range of productAltivar Process ATV600
Product specific applicationProcess and utilities
Product or component typeVariable speed drive
VariantStandard version
Device short nameATV630
Mounting modeWall mount
Communication port protocolModbus TCP
Modbus serial
Ethernet
[Us] rated supply voltage380…480 V – 15…10 %
[Us] rated supply voltage380…480 V
Relative symmetric mains voltage tolerance10 %
Relative symmetric network frequency tolerance5 %
nominal output current5.6 A
IP degree of protectionIP21
Product destinationAsynchronous motors
Synchronous motors
EMC filterIntegrated with 50 m conforming to IEC 61800-3 category C2
Integrated with 150 m conforming to IEC 61800-3 category C3
IP degree of protectionIP21 conforming to IEC 61800-5-1
IP21 conforming to IEC 60529
Degree of protectionUL type 1 conforming to UL 508C
Type of coolingForced convection
Supply frequency50…60 Hz – 5…5 %
Motor power kW2.2 kW (normal duty)
1.5 kW (heavy duty)
Motor power hp3 hp normal duty
2 hp heavy duty
Line current4.3 A at 380 V (normal duty)
3.8 A at 480 V (normal duty)
3.1 A at 380 V (heavy duty)
2.9 A at 480 V (heavy duty)
Continuous output current5.6 A at 4 kHz for normal duty
4 A at 4 kHz for heavy duty
Speed drive output frequency0.1…500 Hz
Safety functionSTO (safe torque off) SIL 3
Option cardSlot A: communication module, Profibus DP V1
Slot A: communication module, PROFINET
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink
Complementary
Discrete input number8
Discrete input typeDI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Discrete input logic16 preset speeds
Discrete output number0
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Analogue input number3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2 voltage analog input: – 10…10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable current DQ-, DQ+: 30 V DC
Software-configurable current DQ-, DQ+: 100 mA
Relay output number3
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Network number of phases3 phases
Physical interfaceEthernet
2-wire RS 485
Method of accessSlave Modbus TCP
Transmission rate10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Transmission frameRTU
Output voltage<= power supply voltage
Permissible temporary current boost1.1 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance
Frequency resolutionDisplay unit: 0.1 Hz
Analog input: 0.012/50 Hz
Electrical connectionControl: removable screw terminals 0.5…1.5 mm²/AWG 20…AWG 16
Motor: screw terminal 2.5…6 mm²/AWG 14…AWG 10
Line side: screw terminal 2.5…6 mm²/AWG 14…AWG 10
Connector typeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
RJ45 (on the remote graphic terminal) for Modbus serial
Exchange modeHalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses1…247 for Modbus serial
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling3 LEDs for local diagnostic
3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
Input compatibilityDI1…DI6: discrete input level 1 PLC conforming to IEC 61131-2
DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
Discrete input logicPositive logic (source) (DI1…DI8), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1…DI8), > 16 V (state 0), < 10 V (state 1)
Sampling duration2 ms +/- 0.5 ms (DI1…DI4) – discrete input
5 ms +/- 1 ms (DI5, DI6) – discrete input
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
10 ms +/- 1 ms (AO1) – analog output
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AO1, AO2: +/- 0.2 % for analog output
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
IsolationBetween power and control terminals
Discrete and process manufacturingBuilding – HVAC compressor centrifugal
Food and beverage processing other application
Mining mineral and metal fan
Mining mineral and metal pump
Oil and gas fan
Water and waste water other application
Building – HVAC screw compressor
Food and beverage processing pump
Food and beverage processing fan
Food and beverage processing atomization
Oil and gas electro submersible pump (ESP)
Oil and gas water injection pump
Oil and gas jet fuel pump
Oil and gas compressor for refinery
Water and waste water centrifuge pump
Water and waste water positive displacement pump
Water and waste water electro submersible pump (ESP)
Water and waste water screw pump
Water and waste water lobe compressor
Water and waste water screw compressor
Water and waste water compressor centrifugal
Water and waste water fan
Water and waste water conveyor
Water and waste water mixer
Power range2.2…3 kW at 380…440 V 3 phases
2.2…3 kW at 480…500 V 3 phases
Enclosure mountingWall mounted
4 quadrant operation possibleFalse
Asynchronous motor control profileConstant torque standard
Optimized torque mode
Variable torque standard
Synchronous motor control profilePermanent magnet motor
Synchronous reluctance motor
Maximum output frequency500 kHz
Acceleration and deceleration rampsLinear adjustable separately from 0.01…9999 s
Motor slip compensationAdjustable
Can be suppressed
Not available in permanent magnet motor law
Automatic whatever the load
Switching frequency2…12 kHz adjustable
4…12 kHz with derating factor
Nominal switching frequency4 kHz
Braking to standstillBy DC injection
Brake chopper integratedFalse
Maximum input current4.3 A
Maximum output voltage480.0 V
Apparent power3.2 kVA at 480 V (normal duty)
2.4 kVA at 480 V (heavy duty)
Maximum transient current6 A during 60 s (heavy duty)
6.2 A during 60 s (normal duty)
Network frequency50…60 Hz
Prospective line Isc50 kA
Base load current at high overload4.0 A
Base load current at low overload5.6 A
Power dissipation in WNatural convection: 30 W at 380 V, switching frequency 4 kHz
Forced convection: 60 W at 380 V, switching frequency 4 kHz
With safety function Safely Limited Speed (SLS)False
With safety function Safe brake management (SBC/SBT)False
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)False
With sft fct Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)True
With safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Protection typeThermal protection: motor
Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Quantity per set1
Width144 mm
Height350 mm
Depth203 mm
Product weight4.5 kg
Environment
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Noise level54.5 dB conforming to 86/188/EEC
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation-15…50 °C (without derating)
50…60 °C (with derating factor)
Operating altitude<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
Operating positionVertical +/- 10 degree
Product certificationsATEX INERIS
CSA
ATEX zone 2/22
TÜV
UL
DNV-GL
MarkingCE
StandardsUL 508C
IEC 61800-3
IEC 61800-3 environment 1 category C2
EN/IEC 61800-3 environment 2 category C3
IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
Maximum THDI<48 % full load conforming to IEC 61000-3-12
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3
Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13…200 Hz
Maximum deflection under vibratory load (during operation)1.5 mm at 2…13 Hz
Permitted relative humidity (during operation)Class 3K5 according to EN 60721-3
Volume of cooling air38 m3/h
Overvoltage categoryIII
Regulation loopAdjustable PID regulator
Noise level54.5 dB
Pollution degree2
Ambient air transport temperature-40…70 °C
Ambient air temperature for storage-40…70 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height31.500 cm
Package 1 Width19.000 cm
Package 1 Length40.500 cm
Package 1 Weight5.939 kg
Unit Type of Package 2S06
Number of Units in Package 26
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight48.634 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • Rated for a 2 kW motor — adjustable output frequency from near 0 to 50/60 Hz gives stepless speed control for pumps, fans, compressors, and conveyor drives.
  • Soft-start acceleration ramp — limits motor starting current to ~1.5× FLC vs. the 6–7× FLC of DOL starting; eliminates mechanical shock on gearboxes, belts, and couplings and reduces peak demand charges.
  • Built-in electronic motor protection — overload, phase-loss, overvoltage (+10%), undervoltage, and short-circuit protection without additional external relays.
  • Manufactured to IEC 61800-5-1 (safety) and IEC 61800-3 (EMC) — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

VW3A1112VW3A3721VW3A3203VW3A3204VW3A5301VW3A5401VW3A3608VW3A3609VW3A3725VW3A3618VW3A3607

❓ Frequently Asked Questions

Q: What environments is the IP21 rating on the ATV630U22N4 suitable for?

A: IP21 means the enclosure is solid particle protection (first digit: 2) and protected against water protection (second digit: 1). This makes the ATV630U22N4 suitable for dry indoor environments with occasional dust. Always verify IP integrity after installation — damaged seals or unused cable entries reduce actual protection.

Q: Can the ATV630U22N4 be used to control a 2 kW motor with soft start and variable speed?

A: Yes. This VFD is rated for a 2 kW motor load and provides stepless speed control from 0 to rated frequency (typically 0–50 Hz). The soft-start ramp eliminates mechanical shock and reduces starting current from typically 6–7× FLC to just 1–1.5× FLC. Ensure the motor cable length does not exceed the VFD manufacturer’s maximum (typically 50–100m without output filter) to avoid insulation stress.

Q: Does the ATV630U22N4 require an input line reactor or output filter for protection?

A: For installations with poor power quality (voltage spikes, harmonics), an input line reactor (3–5% impedance) extends the ATV630U22N4’s life by reducing diode stress and lowering harmonic injection. An output dV/dt filter is recommended when motor cable exceeds 50m to prevent reflected wave damage to motor insulation, especially on older motors not rated for VFD use.

Q: Can the ATV630U22N4 run a standard squirrel-cage induction motor without modification?

A: Yes — standard squirrel-cage induction motors rated for 415V 50Hz can be driven by this VFD. However, at low speeds (<20 Hz), motor cooling is reduced because the shaft-mounted fan slows down. For extended low-speed operation, fit a separately powered external cooling fan on the motor, or use a motor specified for inverter duty.

Q: Does the ATV630U22N4 inject harmonics into the supply and is a line reactor required?

A: VFDs including the ATV630U22N4 generate harmonic currents (primarily 5th and 7th order) due to their diode rectifier front-end. In installations where total harmonic distortion (THD) is a concern — such as facilities with sensitive medical or measurement equipment, or where multiple large drives share a common bus — a 3% or 5% impedance line reactor on the input significantly reduces harmonic injection and protects the drive’s DC bus capacitors from voltage spikes. Check if your site’s power quality specification sets a THD limit.

Customer Reviews