AU HR MCB 100A SP 240V AC 15kA C Curve | L&T – AU15S11003C
₹4,130.00 Original price was: ₹4,130.00.₹1,899.80Current price is: ₹1,899.80. Excl. GST
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
The AU15S11003C AU15S11003C is a miniature circuit breaker (mcb), engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 100 A, 240V AC, 1 Pole. Buy the AU HR MCB 100A SP 240V AC 15kA C Curve | L&T online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | AU15S11003C |
| Part Number / SKU | AU15S11003C |
| Category | Miniature Circuit Breaker (MCB) |
| Current Rating | 100 A |
| Voltage Rating | 240V AC |
| Poles | 1 Pole |
| Breaking Capacity | 15 kA |
| Tripping Curve | Curve C |
| Rated Voltage | 230/400V AC |
| Rated Frequency | 50/60 Hz |
| Magnetic Trip Range | 5–10 × In (per IEC 60898-1) |
| Trip Mechanism | Thermal-magnetic (bimetal overload + electromagnetic short-circuit) |
| Mounting | 35mm DIN rail (EN 60715) |
| Width | 18 mm (1 × 18mm modules) |
| Electrical Endurance | ≥ 20,000 operating cycles (per IEC 60898-1) |
| Pollution Degree | 3 (per IEC 60664-1) |
| Standard | IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) |
| Certifications | BIS certified where applicable |
⚡ Key Features
- Protects circuits at 100 A with 15 kA short-circuit breaking capacity — rated for industrial sub-distribution boards with high prospective fault currents.
- Curve C tripping characteristic — optimised for general-purpose and inductive loads (motors, mixed circuits) — trips magnetically at 5–10× rated current.
- 1 Pole — protects a single-phase final circuit; fits standard 35mm DIN rail in distribution boards.
- Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
- Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised AU15S11003C product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What load can the AU15S11003C protect at its rated 100 A?
A: The AU15S11003C is rated to carry and protect circuits up to 100 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 100 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 15 kA breaking capacity on the AU15S11003C mean in practice?
A: Breaking capacity (15 kA) is the maximum prospective short-circuit current the AU15S11003C can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 15 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Why is Curve C specified for the AU15S11003C and what loads is it optimised for?
A: Curve C on the AU15S11003C trips magnetically at 5–10× rated current, making it ideal for general-purpose circuits including fluorescent lamps, small motors, and mixed loads. Using the wrong curve can cause nuisance tripping (too sensitive) or inadequate protection (not sensitive enough). Always match the curve to the load’s inrush characteristics.
Q: Is the AU15S11003C suitable for both single-phase and three-phase systems?
A: The AU15S11003C is a 1 pole device for single-phase circuits. For three-phase circuits, use a 3-pole or 4-pole MCB of the same series.
Q: Can the AU15S11003C be DIN rail mounted in any standard distribution board?
A: Yes. This AU15S11003C MCB uses the standard 35mm EN 60715 DIN rail and 17.5mm module width, making it compatible with all major brand distribution boards and enclosures. Terminal capacity accommodates both rigid and flexible conductors up to the rated cross-section.