AU RCCB 40A DP 240V Adi 100mA L T AURAD204010 aurad204003 au r rccb 40 a 30ma adi 2p front
AU RCCB 100A DP 240V Adi 300mA | L&T - AURAD210030 Original price was: ₹14,765.00.Current price is: ₹6,791.90. Excl. GST
Back to products
AU RCCB 25A FP 415V Adi 300mA L T AURAD402530 aurad404003 au r rccb 40 a 30ma adi 4p front
AU RCCB 40A FP 415V Adi 30mA | L&T - AURAD404003 Original price was: ₹9,975.00.Current price is: ₹4,588.50. Excl. GST

AU RCCB 25A FP 415V Adi 30mA | L&T – AURAD402503

SKU: AURAD402503

Original price was: ₹9,605.00.Current price is: ₹4,418.30. Excl. GST

Available on back-order

Available on back-order

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Sourced through authorised channels, the AURAD402503 AURAD402503 rccb delivers dependable performance for reliable circuit protection and isolation. Key ratings include 25 A, 415V AC, 4 Poles. myelectric.in stocks the AU RCCB 25A FP 415V Adi 30mA | L&T for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.

📋 Technical Specifications

ParameterValue
BrandAURAD402503
Part Number / SKUAURAD402503
CategoryRCCB
Current Rating25 A
Voltage Rating415V AC
Poles4 Poles
Sensitivity30 mA
Rated Voltage415V AC (3-phase 4-wire)
Rated Frequency50 Hz
Max Break Time≤ 300 ms at rated IΔn (per IEC 61008-1)
RCD TypeType AC (sinusoidal AC sensitive)
Protection FunctionEarth leakage only — pair with upstream MCB for overcurrent
Mounting35mm DIN rail (EN 60715)
Test FacilityBuilt-in test button (monthly test per IS 12640)
StandardIEC 61008 / IS 12640-1
CertificationsBIS certified where applicable

⚡ Key Features

  • 30 mA sensitivity — standard personnel shock protection — trips before a lethal current (>50mA) can flow through the body (IEC 61008).
  • 25 A rated load current — the RCCB carries this full circuit current continuously while monitoring the live-neutral balance for any earth leakage.
  • 4 Poles — for three-phase four-wire (TN-S/TT) installations; all four conductors pass through the toroidal CT for complete leakage detection.
  • Earth-leakage protection only — no overload or short-circuit protection; install in series with an appropriately rated MCB for full circuit protection.
  • Mandatory test button — simulate a leakage fault to verify the trip mechanism without live fault conditions; test monthly per IS 12640 recommendation.
  • Type AC — designed for purely sinusoidal AC residual currents on standard residential and commercial circuits.
  • Manufactured to IEC 61008 / IS 12640-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised AURAD402503 product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.

❓ Frequently Asked Questions

Q: What is the significance of the 25 A rating on the AURAD402503?

A: The 25 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.

Q: Why is the 30 mA sensitivity specified on the AURAD402503 and when should you choose a different rating?

A: 30 mA is the residual current at which the AURAD402503 will trip within 300ms. A 30mA sensitivity provides additional shock protection (mandatory for socket circuits per IS 732). 100mA is used for fire protection (no shock protection). 300mA protects feeders without nuisance tripping. Choose based on the circuit’s risk profile — never use >30mA for socket outlet circuits in wet or high-risk locations.

Q: Will the AURAD402503 trip on earth faults from variable frequency drives (VFDs)?

A: VFDs, LED drivers, and switched-mode power supplies generate high-frequency leakage currents that can cause nuisance tripping in standard Type AC RCCBs. If your installation includes VFDs, use a Type A (for pulsating DC components) or Type F/B RCCB. The AURAD402503 specification (AC or A type) determines suitability — check the product marking.

Q: How many downstream circuits can be protected under the AURAD402503 without nuisance tripping?

A: Downstream MCBs or RCBOs can be connected below the AURAD402503, but the total standing leakage current of all connected circuits must not exceed 30–50% of the RCCB’s rated sensitivity — typically 9–15mA for a 30mA device. Each appliance with a filter (computers, VFDs, LED drivers) contributes 0.5–3mA of standing leakage, so limit the count of such loads per RCCB to prevent cumulative leakage causing nuisance tripping.

Q: What is the difference between an RCCB and a standard MCB — and why use the AURAD402503?

A: A standard MCB protects against overload and short-circuit only. An RCCB adds earth leakage (residual current) detection — it trips on faults as low as 30mA to ground, protecting against electric shock and fire from insulation faults, which a standard MCB cannot detect. Choose the AURAD402503 when the application specifically requires rccb characteristics.