The Schneider Electric C63F3TM500D is a mccb, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 630 A, 3 Poles. Buy the C63F3TM500D | NSX630F 36kA DC 3P 500A TMD online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Part Number / SKU | C63F3TM500D |
| Category | MCCB |
| Current Rating | 630 A |
| Frame Size | 630 A |
| Poles | 3 Poles |
| Breaking Capacity | 36 kA |
| Rated Operational Voltage (Ue) | 415V AC (50/60 Hz) |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Impulse Withstand (Uimp) | 8 kV |
| Service Breaking Capacity (Ics) | 100% of Icu |
| Trip Unit Type | Thermal-magnetic (TMD) |
| Mounting | Fixed, front connected |
| Rated Frequency | 50/60 Hz |
| Standard | IEC 60947-2 / IS 13947-2 |
| Certifications | BIS certified, CE marked, RoHS compliant |
⚡ Key Features
- 630 A frame rating — handles the full rated current continuously; designed for feeder and sub-distribution protection where fault levels exceed MCB capability.
- Performance level F — breaking capacity 36 kA (standard breaking capacity, suitable for commercial and light industrial boards).
- TMD (Thermal-Magnetic) trip unit — adjustable overload setting (Ir) from 0.7–1× In with fixed instantaneous magnetic trip; simple and reliable for standard feeder applications.
- 3 Poles — three-phase feeder protection; neutral not switched (TN-C / IT systems).
- CompacT NSX form factor — 70mm wide per pole; designed for high-density LV switchboards with up to 3 units per standard 250mm busbar bay.
- Rotary handle with padlocking points — LOTO compliant; handle locks in OFF position with up to 3 padlocks, preventing accidental energisation during maintenance.
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
❓ Frequently Asked Questions
Q: What load can the C63F3TM500D protect at its rated 630 A?
A: The C63F3TM500D is rated to carry and protect circuits up to 630 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 630 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 36 kA breaking capacity on the C63F3TM500D mean in practice?
A: Breaking capacity (36 kA) is the maximum prospective short-circuit current the C63F3TM500D can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 36 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Can the C63F3TM500D be motorised for remote switching and automation?
A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: What trip unit type does the C63F3TM500D use — thermal-magnetic or electronic?
A: The C63F3TM500D uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.
Q: Is the C63F3TM500D suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.