DN2S MCCB 200 4P 415V AC 70kA Thermal Magnetic 50/60 Hz | L&T – CM92103OON1OG
₹71,000.00 Original price was: ₹71,000.00.₹32,660.00Current price is: ₹32,660.00. Excl. GST
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Looking for the DN2S MCCB 200 4P 415V AC 70kA Thermal Magnetic 50/60 Hz | L&T? This genuine CM92103OON1OG mccb is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 415V AC, 4 Poles. Order part number CM92103OON1OG from myelectric.in — a trusted CM92103OON1OG supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | CM92103OON1OG |
| Part Number / SKU | CM92103OON1OG |
| Category | MCCB |
| Voltage Rating | 415V AC |
| Poles | 4 Poles |
| Breaking Capacity | 70 kA |
| Frequency | 60 Hz |
| Rated Operational Voltage (Ue) | 415V AC (50/60 Hz) |
| Mounting | Fixed, front connected |
| Rated Frequency | 50/60 Hz |
| Standard | IEC 60947-2 / IS 13947-2 |
| Certifications | BIS certified where applicable |
⚡ Key Features
- 70 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
- Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
- 4 Poles — three-phase + switched neutral (TN-S system) for full four-pole isolation per IEC 60364.
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised CM92103OON1OG product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What does the 70 kA breaking capacity on the CM92103OON1OG mean in practice?
A: Breaking capacity (70 kA) is the maximum prospective short-circuit current the CM92103OON1OG can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 70 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Can the CM92103OON1OG be motorised for remote switching and automation?
A: Yes. CM92103OON1OG MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: What trip unit type does the CM92103OON1OG use — thermal-magnetic or electronic?
A: The CM92103OON1OG uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.
Q: Is the CM92103OON1OG suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the CM92103OON1OG coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.
Q: After a short-circuit trip on the CM92103OON1OG, can it be reset and reused immediately?
A: After a short-circuit trip, do not immediately reset the CM92103OON1OG. First, identify and clear the fault. Then inspect the device — if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 70 kA rated breaking capacity is not unlimited — it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1–3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.