DN4N MCCB 1250 4P 415V AC 50kA MTX2.0 50/60 Hz | L&T – CM96113OOOOAG
₹302,200.00 Original price was: ₹302,200.00.₹139,012.00Current price is: ₹139,012.00. Excl. GST
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Sourced through authorised channels, the CM96113OOOOAG CM96113OOOOAG mccb delivers dependable performance for reliable circuit protection and isolation. Key ratings include 415V AC, 4 Poles. myelectric.in stocks the DN4N MCCB 1250 4P 415V AC 50kA MTX2.0 50/60 Hz | L&T for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | CM96113OOOOAG |
| Part Number / SKU | CM96113OOOOAG |
| Category | MCCB |
| Voltage Rating | 415V AC |
| Poles | 4 Poles |
| Breaking Capacity | 50 kA |
| Frequency | 60 Hz |
| Rated Operational Voltage (Ue) | 415V AC (50/60 Hz) |
| Mounting | Fixed, front connected |
| Rated Frequency | 50/60 Hz |
| Standard | IEC 60947-2 / IS 13947-2 |
| Certifications | BIS certified where applicable |
⚡ Key Features
- 50 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
- Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
- 4 Poles — three-phase + switched neutral (TN-S system) for full four-pole isolation per IEC 60364.
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised CM96113OOOOAG product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What does the 50 kA breaking capacity on the CM96113OOOOAG mean in practice?
A: Breaking capacity (50 kA) is the maximum prospective short-circuit current the CM96113OOOOAG can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 50 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: What trip unit type does the CM96113OOOOAG use — thermal-magnetic or electronic?
A: Refer to the product label or datasheet for the exact trip unit specification. The trip unit determines adjustability and protection accuracy.
Q: Is the CM96113OOOOAG suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the CM96113OOOOAG coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.
Q: Can the CM96113OOOOAG be motorised for remote switching and automation?
A: Yes. CM96113OOOOAG MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: After a short-circuit trip on the CM96113OOOOAG, can it be reset and reused immediately?
A: After a short-circuit trip, do not immediately reset the CM96113OOOOAG. First, identify and clear the fault. Then inspect the device — if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 50 kA rated breaking capacity is not unlimited — it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1–3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.













