DU125H MCCB 125A 4P 415V AC 30kA Thermal Magnetic 50 60 Hz L T CM90679OOLO cm90679oolo mccb du125h 125a 4p tm 9in front
DU125H MCCB 125A 4P 415V AC 30kA Thermal Magnetic 50/60 Hz | L&T - CM90679OOLO Original price was: ₹11,400.00.Current price is: ₹6,840.00. Excl. GST
Back to products
DU250 MCCB 250A 3P 415V AC 36kA Thermal Magnetic 50 60 Hz L T CM98060OOOO cm98060oooo mccb du250 250a 3p tm mccb front
DU250 MCCB 200A 3P 415V AC 36kA Thermal Magnetic 50/60 Hz | L&T - CM98061OOOO Original price was: ₹16,900.00.Current price is: ₹10,140.00. Excl. GST

DU250 MCCB 160A 3P 415V AC 36kA Thermal Magnetic 50/60 Hz | L&T – CM98062OOOO

SKU: CM98062OOOO

Original price was: ₹13,800.00.Current price is: ₹8,280.00. Excl. GST

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Sourced through authorised channels, the CM98062OOOO CM98062OOOO mccb delivers dependable performance for reliable circuit protection and isolation. Key ratings include 160 A, 415V AC, 3 Poles. myelectric.in stocks the DU250 MCCB 160A 3P 415V AC 36kA Thermal Magnetic 50/60 Hz | L&T for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.

📋 Technical Specifications

ParameterValue
BrandCM98062OOOO
Part Number / SKUCM98062OOOO
CategoryMCCB
Current Rating160 A
Voltage Rating415V AC
Poles3 Poles
Breaking Capacity36 kA
Frequency60 Hz
Rated Operational Voltage (Ue)415V AC (50/60 Hz)
MountingFixed, front connected
Rated Frequency50/60 Hz
StandardIEC 60947-2 / IS 13947-2
CertificationsBIS certified where applicable

⚡ Key Features

  • 36 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in industrial main distribution boards.
  • Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
  • 3 Poles — three-phase feeder protection; neutral not switched (TN-C / IT systems).
  • Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised CM98062OOOO product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

❓ Frequently Asked Questions

Q: What load can the CM98062OOOO protect at its rated 160 A?

A: The CM98062OOOO is rated to carry and protect circuits up to 160 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 160 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 36 kA breaking capacity on the CM98062OOOO mean in practice?

A: Breaking capacity (36 kA) is the maximum prospective short-circuit current the CM98062OOOO can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 36 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: Can the CM98062OOOO be motorised for remote switching and automation?

A: Yes. CM98062OOOO MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.

Q: What trip unit type does the CM98062OOOO use — thermal-magnetic or electronic?

A: The CM98062OOOO uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.

Q: Is the CM98062OOOO suitable for use as a motor branch circuit protector (Type E coordination)?

A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the CM98062OOOO coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.

Customer Reviews