EXORA MCB 32A DP 500V DC 10kA C Curve L T bj2016dc mcb dp 16a 500v dc 10ka front
EXORA MCB 4A DP 500V DC 10kA C Curve | L&T Original price was: ₹2,105.00.Current price is: ₹968.30. Excl. GST
Back to products
EXORA MCB 32A DP 500V DC 10kA C Curve L T bj2016dc mcb dp 16a 500v dc 10ka front
EXORA MCB 10A DP 500V DC 10kA C Curve | L&T Original price was: ₹1,780.00.Current price is: ₹818.80. Excl. GST

EXORA MCB 6A DP 500V DC 10kA C Curve | L&T

SKU: BJ2006DC

Original price was: ₹1,780.00.Current price is: ₹818.80. Excl. GST

Out of stock

Out of stock

17 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

📋 Technical Specifications

ParameterValue
BrandL&T
Part Number / SKUBJ2006DC
CategoryMiniature Circuit Breaker (MCB)
Current Rating6 A
Voltage Rating500V AC
Poles2 Poles
Breaking Capacity10 kA
Tripping CurveCurve C
StandardIS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial)
CertificationsBIS certified where applicable

⚡ Key Features

  • Protects circuits at 6 A with 10 kA short-circuit breaking capacity — rated for light industrial and commercial distribution boards.
  • Curve C tripping characteristic — optimised for general-purpose and inductive loads (motors, mixed circuits) — trips magnetically at 5–10× rated current.
  • 2 Poles — protects a single-phase circuit, switching both live and neutral; fits standard 35mm DIN rail in distribution boards.
  • Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
  • Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised L&T product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

❓ Frequently Asked Questions

Q: What load can the BJ2006DC protect at its rated 6 A?

A: The BJ2006DC is rated to carry and protect circuits up to 6 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 6 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 10 kA breaking capacity on the BJ2006DC mean in practice?

A: Breaking capacity (10 kA) is the maximum prospective short-circuit current the BJ2006DC can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 10 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: Why is Curve C specified for the BJ2006DC and what loads is it optimised for?

A: Curve C on the BJ2006DC trips magnetically at 5–10× rated current, making it ideal for general-purpose circuits including fluorescent lamps, small motors, and mixed loads. Using the wrong curve can cause nuisance tripping (too sensitive) or inadequate protection (not sensitive enough). Always match the curve to the load’s inrush characteristics.

Q: Is the BJ2006DC suitable for both single-phase and three-phase systems?

A: The BJ2006DC is a 2 poles device for single-phase circuits. For three-phase circuits, use a 3-pole or 4-pole MCB of the same series.

Q: Can the BJ2006DC be DIN rail mounted in any standard distribution board?

A: Yes. This L&T MCB uses the standard 35mm EN 60715 DIN rail and 17.5mm module width, making it compatible with all major brand distribution boards and enclosures. Terminal capacity accommodates both rigid and flexible conductors up to the rated cross-section.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “EXORA MCB 6A DP 500V DC 10kA C Curve | L&T”

Your email address will not be published. Required fields are marked *