The Schneider Electric EZ9F71116 is a miniature circuit breaker (mcb) from the Easy9 range, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 16 A, 240 V AC 50/60 Hz, 1 Pole. Buy the EZ9F71116 | Easy9 MCB 1P 16A C 10000A 240V online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | EZ9F71116 |
| Category | Miniature Circuit Breaker (MCB) |
| Main | |
| Range | Easy9 |
| Device application | Distribution |
| Product or component type | Miniature circuit-breaker |
| Device short name | Easy9 MCB |
| Poles | 1P |
| Number of protected poles | 1 |
| [In] rated current | 16 A |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10000 A Icn at 240 V AC 50/60 Hz conforming to IEC 60898-1 |
| Suitability for isolation | Yes conforming to IEC 60898-1 |
| Complementary | |
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 240 V AC 50/60 Hz |
| Magnetic tripping limit | 5…10 x In |
| [Ics] rated service breaking capacity | 10 kA 75 % x Icn at 240 V AC 50/60 Hz conforming to IEC 60898-1 |
| Limitation class | 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to IEC 60898-1 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to IEC 60898-1 |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | Without |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| 9 mm pitches | 2 |
| Height | 81 mm |
| Width | 18 mm |
| Depth | 77.5 mm |
| Product weight | 0.115 kg |
| Colour | Grey (RAL 7035) |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles |
| Connections – terminals | Tunnel type terminal (top or bottom) 1…25 mm² rigid Tunnel type terminal (top or bottom) 1…16 mm² flexible |
| Tightening torque | 2 N.m top or bottom |
| Environment | |
| Standards | IEC 60898-1 |
| Product certifications | CE ISI |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Pollution degree | 2 |
| Tropicalisation | 2 |
| Relative humidity | 95 % at -5…55 °C |
| Ambient air temperature for operation | -5…55 °C |
| Ambient air temperature for storage | -25…85 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8 cm |
| Package 1 Width | 2 cm |
| Package 1 Length | 9 cm |
| Package 1 Weight | 0.115 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 144 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 16.56 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Protects circuits at 16 A with 10 kA short-circuit breaking capacity — rated for light industrial and commercial distribution boards.
- 1 Pole — protects a single-phase final circuit; fits standard 35mm DIN rail in distribution boards.
- Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
- Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What load can the EZ9F71116 protect at its rated 16 A?
A: The EZ9F71116 is rated to carry and protect circuits up to 16 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 16 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 10 kA breaking capacity on the EZ9F71116 mean in practice?
A: Breaking capacity (10 kA) is the maximum prospective short-circuit current the EZ9F71116 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 10 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Can the EZ9F71116 be DIN rail mounted in any standard distribution board?
A: Yes. This Schneider Electric MCB uses the standard 35mm EN 60715 DIN rail and 17.5mm module width, making it compatible with all major brand distribution boards and enclosures. Terminal capacity accommodates both rigid and flexible conductors up to the rated cross-section.
Q: What happens when the EZ9F71116 trips — how do I identify and reset it?
A: When the EZ9F71116 trips on fault, the handle moves to a midway position (between ON and OFF), distinctly visible from a distance. To reset: (1) identify and rectify the fault, (2) push the handle fully to OFF, (3) then switch back to ON. Never force-reset without investigating the fault cause.
Q: Is the EZ9F71116 suitable for both single-phase and three-phase systems?
A: The EZ9F71116 is a 1 pole device for single-phase circuits. For three-phase circuits, use a 3-pole or 4-pole MCB of the same series.