28908 | INS100 3P 100A - Schneider Electric
28908 | INS100 3P 100A - Schneider Electric Original price was: ₹15,160.00.Current price is: ₹13,037.60. Excl. GST
Back to products
E83T727V_WG | Avataron-20Va Universal Shaver Socket, Wg - Schneider Electric
E83T727V_WG | Avataron-20Va Universal Shaver Socket, Wg - Schneider Electric Original price was: ₹11,269.00.Current price is: ₹6,874.09. Excl. GST

EZC250H2125 | Mccb-Easypact Ezc, Ezc250H2125, 125A, 85Ka, 2Pole Mccb – Schneider Electric

SKU: EZC250H2125

Original price was: ₹16,210.00.Current price is: ₹8,105.00. Excl. GST

Dispatch By : 2 Weeks

Dispatch By : 2 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: EZC250H2125

Same-day dispatch · GST invoice available

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the EZC250H2125 | Mccb-Easypact Ezc, Ezc250H2125, 125A, 85Ka, 2Pole Mccb? This genuine Schneider Electric mccb from the EasyPact range is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 125 A at 40 °C, 550 V AC 50/60 Hz, 2P. Order part number EZC250H2125 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUEZC250H2125
CategoryMCCB
Main
Range of productEasyPact
Product or component typeCircuit breaker
Device short nameEasypact EZC250H
Circuit breaker nameEasypact EZC250H
Device applicationDistribution
Poles description2P
Protected poles description2t
Network typeAC
DC
Network frequency50/60 Hz
[In] rated current125 A at 40 °C
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
[Ue] rated operational voltage550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
Breaking capacity codeH
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 125 V DC 1P conforming to IEC 60947-2
30 kA Icu at 250 V DC 2P conforming to IEC 60947-2
36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 125 V DC conforming to IEC 60947-2
15 kA at 250 V DC conforming to IEC 60947-2
18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating125 A at 50 °C
Protection typeShort-circuit protection
Overload protection
Pollution degree3 conforming to IEC 60664-1
3 conforming to IEC 947-1
Complementary
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Upside connectionFront
Downside connectionFront
Mechanical durability10000 cycles
Connection pitch35 mm
Local signallingPositive contact indication
Neutral protection settingWithout protection
Earth-leakage protectionWithout
Height165 mm
Width105 mm
Depth60 mm
Environment
StandardsEN/IEC 60947-1
EN/IEC 60947-2
GB/T 14048.2
JIS C8201-2-2
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-35…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.400 cm
Package 1 Width11.300 cm
Package 1 Length18.000 cm
Package 1 Weight1.480 kg
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight12.327 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 85 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
  • Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
  • 2 Poles — protects the connected feeder circuit.
  • Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

EZEROTEEZEROTDSEZESPDR3PEZESHT200ACEZEAXEZEAXALEZEUVR200ACEZEAL

❓ Frequently Asked Questions

Q: What load can the EZC250H2125 protect at its rated 125 A?

A: The EZC250H2125 is rated to carry and protect circuits up to 125 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 125 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 85 kA breaking capacity on the EZC250H2125 mean in practice?

A: Breaking capacity (85 kA) is the maximum prospective short-circuit current the EZC250H2125 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 85 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: Can the EZC250H2125 be motorised for remote switching and automation?

A: Yes. Schneider Electric MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.

Q: What trip unit type does the EZC250H2125 use — thermal-magnetic or electronic?

A: Refer to the product label or datasheet for the exact trip unit specification. The trip unit determines adjustability and protection accuracy.

Q: Is the EZC250H2125 suitable for use as a motor branch circuit protector (Type E coordination)?

A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Schneider Electric coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.

Customer Reviews