GV4AU137 | Coil Uvr Mn,110-130V Ac/Dc For Gv4,Bv4 – Schneider Electric
₹13,300.00 Excl. GST
Dispatch By : 9 Weeks
Dispatch By : 9 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
GV4P80N | MotBreak GV4P Therm/Mag 80A 50kA Elink – Schneider Electric
Looking for the GV4AU137 | Coil Uvr Mn,110-130V Ac/Dc For Gv4,Bv4? This genuine Schneider Electric electrical component from the TeSys range is built for industrial, commercial, and infrastructure applications, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 110–130V AC/DC. Order part number GV4AU137 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | GV4AU137 |
| Category | Electrical Component |
| Main | |
| Range | TeSys |
| Device short name | MN |
| Product or component type | Voltage release |
| Device application | Control |
| Range compatibility | TeSys TeSys GV4 TeSys TeSys BV4 |
| Voltage release type | Undervoltage release |
| [Uc] control circuit voltage | 110…130 V AC 50/60 Hz 125 V DC |
| Complementary | |
| [Ui] rated insulation voltage | 130 V conforming to IEC 60947-1 |
| Threshold tripping voltage | < 0.35 Un failsafe opening 0.35…0.7 Un possible opening 0.85…1.1 Un enabled closing |
| Mounting mode | Internal mounting |
| Maximum inrush power in VA | 7 VA |
| Maximum inrush power in W | 2 W |
| Maximum hold-in power consumption in VA | 7 VA |
| Maximum hold-in power consumption in W | 2 W |
| Mechanical durability | 20000 cycles |
| Operating time | < 50 ms |
| Connections – terminals | Spring terminals 1 0.5…1.5 mm² – cable stiffness: flexible without cable end |
| Wire stripping length | 8 mm |
| Environment | |
| Quantity per set | Set of 1 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.400 cm |
| Package 1 Width | 6.200 cm |
| Package 1 Length | 8.500 cm |
| Package 1 Weight | 61.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 8.800 cm |
| Package 2 Width | 13.000 cm |
| Package 2 Length | 18.500 cm |
| Package 2 Weight | 684.000 g |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 160 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 17.600 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 110–130V AC/DC coil or control supply voltage — directly compatible with standard panel control circuits.
- Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: The GV4AU137 has a coil voltage of 110–130V AC/DC — what control supply is needed?
A: This Schneider Electric device requires a 110–130V AC/DC control supply connected to the coil terminals (A1 and A2). For DC coils, observe polarity where marked. DC coils produce no inrush and are preferred for PLC output cards. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.













