IMD-IM400-1700C | IM400-1700C Voltage Adaptor for IM400 - Schneider Electric
₹27,318.00 Original price was: ₹27,318.00.₹14,205.36Current price is: ₹14,205.36. Excl. GST
IMD-IM400VA2 | IM400VA2 Voltage Adaptor for IM400 in PV - Schneider Electric
₹34,959.00 Original price was: ₹34,959.00.₹18,178.68Current price is: ₹18,178.68. Excl. GST
IMD-IM400C | IM400C Insulation Monitoring Device – Schneider Electric
SKU:
IMD-IM400C
₹202,997.00 Original price was: ₹202,997.00.₹105,558.44Current price is: ₹105,558.44. Excl. GST
Dispatch By : 4 Weeks
Dispatch By : 4 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included
Dedicated account manager
Technical support
Bulk & business pricing
3-day replacement
Specifications
| Main | |
|---|---|
| Range | Vigilohm |
| Device short name | IM400C |
| Product or component type | Insulation monitoring device |
| Type of IMD | AC/DC IMD |
| Earthing system | IT HRG |
| Application | Marine and offshore Industry Infrastructure Power generation Port, airport, railway Photovoltaic |
| Network size | Large |
| Electrical circuit type | Power circuit Control circuit |
| Network capacitance | Highly capacitive |
| Type of network | 1P + N 3P 3P + N |
| Network rated voltage | 0…480 V – AC at 45…440 Hz (device connected to phase) 0…830 V – AC at 45…440 Hz (device connected to neutral) 0…480 V – DC |
| Complementary | |
| Alarm threshold setting | Pre-alarm: 1 kOhm…1 MOhm Alarm: 40 Ohm…500 kOhm |
| Type of measurement | Network insulation resistance, range: 10 Ohm…10 MOhm, accuracy: +/- 1 % Earth leakage capacitance, range: 0.01…5500 µF, accuracy: +/- 5 % |
| Configurable filtering time | 4 s 40 s 400 s |
| Response time | 0.8 s 1/5th of set filtering time 8 s 1/5th of set filtering time 80 s 1/5th of set filtering time |
| Time delay range | 0…120 min for signalling circuit 0…120 min for alarm |
| Power quality analysis | Transient capture |
| Input type | Contact for injection inhibition Dry contact Contact for injection inhibition Modbus |
| Operating mode | Control Power Marine Photovoltaic Railway |
| Self-test | Manual Auto test at start and every 5h |
| Overvoltage category | III 300 V II 600 V |
| IP degree of protection | Case: IP20 Front face: IP54 |
| Material | Thermoplastic |
| Harsh environment | Coated |
| Physical | |
| Type of installation | Indoor Enclosed outdoor |
| Operating altitude | <= 3000 m |
| Relative humidity | 0…95 % |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Pollution degree | 2 |
| Mounting mode | Flush-mounted (panel) |
| Mounting position | Horizontal |
| Connections – terminals | Removable screw terminal block 0.2…2.5 mm² |
| Net weight | 0.66 kg |
| Cut-out dimensions | 112 x 148 mm |
| Height | 123 mm |
| Width | 159 mm |
| Depth | 90 mm |
| Communications & Management | |
| Display type | LCD display |
| Information displayed | Resistance value Capacitance value Evolution of resistance in graph |
| User language | Portuguese Italian French German English Chinese Russian Spanish |
| Local signalling | Green indicator light: satisfactory insulation resistance White indicator light: below prevention threshold Red indicator light: wiring or internal fault Yellow indicator light: insulation fault Yellow flashing indicator light: communication |
| Signal contacts composition | 2 C/O standard or fail-safe |
| Signalling circuit voltage | 250 V – AC at 3 A 48 V – DC at 1 A |
| Communication port protocol | Modbus RS485 |
| Communication of data | HMI: test reports Dry contact: test reports |
| Fault event log | Alarm logs Time stamping 30 events |
| Supported Hardware | |
| Product compatibility | Automatic fault locator |
| Power Requirements | |
| [Us] rated supply voltage | 100…440 V AC 50/60/400 Hz tolerance: +/- 15 % 100…440 V DC tolerance: +/- 15 % |
| Power consumption in VA | 25 VA |
| Power consumption in W | 10 W |
| Overcurrent protection | 1 A |
| Standards | |
| Standards | IEC 60364-4-41 IEC 61010-1 IEC 61557-8 UL 61010-1 IEC 61326-2-4 EN/IEC 61508 level SIL2 UL 1998 |
| Product certifications | RMRS DNV CSA ABS UL cULus EAC CE EU-RO MR TA RCM |
| Environmental characteristic | Exposure to damp heat not in service conforming to IEC 60068-2-30 Exposure to damp heat in service conforming to IEC 60068-2-56 Salt mist conforming to IEC 60068-2-52 Long-term storage class 1K22 conforming to IEC 60721-3-1 Transport class 2K11 conforming to IEC 60721-3-2 Stationary use at weather protected locations class 3K24 conforming to IEC 60721-3-3 |
| Mechanical robustness | Long-term storage class 1M11 conforming to IEC 60721-3-1 Transport class 2M4 conforming to IEC 60721-3-2 Stationary use class 3M11 conforming to IEC 60721-3-3 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.5 cm |
| Package 1 Width | 18.0 cm |
| Package 1 Length | 21.5 cm |
| Package 1 Weight | 953.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 4.442 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
Customer Reviews
Related Products
XB5AR31N | Push button, Harmony XB5N XB7N, plastic, mushroom, green, 60mm, spring return, unmarked, 1 NO – Schneider Electric
SKU:
XB5AR31N
ZB2BW36C | Ø 22 mm fixing hole – push button head with blue lamp – Schneider Electric
SKU:
ZB2BW36C
MS13MD09 | 7MDL, 1HP 3 PHASE DOL STARTER – Schneider Electric
SKU:
MS13MD09
30002572 | EM1200 Energy meter Cl 0.5 RS485 LCD – Schneider Electric
SKU:
30002572














