XB5KS2B4 | CONTINUOUS ORINTERMITENT ILLUMINATED RE - Schneider Electric
XB5KS2B4 | CONTINUOUS ORINTERMITENT ILLUMINATED RE - Schneider Electric Original price was: ₹26,506.00.Current price is: ₹16,698.78. Excl. GST
Back to products

LC1D40008E7 | 4P CONT 60A AC-1 2NO 2NC 48VAC COIL – Schneider Electric

SKU: LC1D40008E7

Original price was: ₹42,920.00.Current price is: ₹19,314.00. Excl. GST

Dispatch By : 3 Weeks

Dispatch By : 3 Weeks

17 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1D40008E7 | 4P CONT 60A AC-1 2NO 2NC 48VAC COIL? This genuine Schneider Electric electrical component from the TeSys range is built for industrial, commercial, and infrastructure applications, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 60 A, Power circuit: <= 690 V AC 25...400 Hz, 4P. Order part number LC1D40008E7 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1D40008E7
CategoryElectrical Component
Main
RangeTeSys
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage48 V AC 50/60 Hz
Complementary
Compatibility codeLC1D
Pole contact composition2 NO + 2 NC
Protective coverWith
[Ith] conventional free air thermal current60 A (at 60 °C) for power circuit
Irms rated making capacity800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current320 A 40 °C – 10 s for power circuit
720 A 40 °C – 1 s for power circuit
72 A 40 °C – 10 min for power circuit
165 A 40 °C – 1 min for power circuit
Associated fuse rating80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance1.5 mOhm – Ith 60 A 50 Hz for power circuit
Power dissipation per pole5.4 W AC-1
[Ui] rated insulation voltagePower circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Electrical durability1.4 Mcycles 60 A AC-1 at Ue <= 440 V
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation4…5 W at 50/60 Hz
Operating time4…19 ms opening
12…26 ms closing
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 8 N.m – on screw clamp terminals – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on screw clamp terminals – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Mounting supportRail
Plate
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
Product certificationsCCC
CSA
BV
UL
DNV
RINA
LROS (Lloyds register of shipping)
GOST
GL
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessShocks contactor open (8 Gn for 11 ms)
Shocks contactor closed (10 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Height127 mm
Width85 mm
Depth125 mm
Product weight1.44 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.500 cm
Package 1 Width11.000 cm
Package 1 Length13.800 cm
Package 1 Weight1.474 kg
Unit Type of Package 2S02
Number of Units in Package 25
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.639 kg
Unit Type of Package 3P06
Number of Units in Package 380
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight133.060 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 60 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
  • 48V AC coil or control supply voltage — directly compatible with standard panel control circuits.
  • Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LAD9ET1SLA4DA2ELA4DE1ELADN22LADN11LADN20LAD8N11LADT2LADN40LADN31LADN02LADT0LAD8N20LADS2LADR2LADR0LADN04LADN13LADR4LADT4LAD8N02LX1D6E7

❓ Frequently Asked Questions

Q: What is the significance of the 60 A rating on the LC1D40008E7?

A: The 60 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.

Q: The LC1D40008E7 has a coil voltage of 48V AC — what control supply is needed?

A: This Schneider Electric device requires a 48V AC control supply connected to the coil terminals (A1 and A2). For AC coils, ensure the control circuit voltage is stable — voltage drops below 85% of rated coil voltage can cause chatter and coil overheating. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.

Customer Reviews