LC1D40008U7 | 4P CONT 60A AC-1 2NO 2NC 240VAC COIL - Schneider Electric
LC1D40008U7 | 4P CONT 60A AC-1 2NO 2NC 240VAC COIL - Schneider Electric Original price was: ₹40,150.00.Current price is: ₹18,067.50. Excl. GST
Back to products
LC1D40A6BBE | TeSys CONT 3P 40A AC3 NO+NC 24V DC LUGS - Schneider Electric
LC1D40A6BBE | TeSys CONT 3P 40A AC3 NO+NC 24V DC LUGS - Schneider Electric Original price was: ₹26,500.00.Current price is: ₹11,925.00. Excl. GST

LC1D406FWS207 | CONTACTOR 3P AC3 440V 40A COIL 110VDC RA – Schneider Electric

SKU: LC1D406FWS207

Original price was: ₹53,770.00.Current price is: ₹24,196.50. Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

16 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
TeSys Deca
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Motor control
Utilisation categoryAC-1
AC-3
AC-3e
Poles description3P
[Ue] rated operational voltagePower circuit: <= 1000 V AC 25…400 Hz
[Ie] rated operational current60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Complementary
Motor power kW11 kW at 220/230 V AC 50 Hz (AC-3)
18.5 kW at 380/400 V AC 50 Hz (AC-3)
22 kW at 415 V AC 50 Hz (AC-3)
22 kW at 440 V AC 50 Hz (AC-3)
22 kW at 500 V AC 50 Hz (AC-3)
30 kW at 660/690 V AC 50 Hz (AC-3)
22 kW at 1000 V AC 50 Hz (AC-3)
11 kW at 220/230 V AC 50 Hz (AC-3e)
18.5 kW at 380/400 V AC 50 Hz (AC-3e)
22 kW at 415 V AC 50 Hz (AC-3e)
22 kW at 440 V AC 50 Hz (AC-3e)
22 kW at 500 V AC 50 Hz (AC-3e)
30 kW at 660/690 V AC 50 Hz (AC-3e)
22 kW at 1000 V AC 50 Hz (AC-3e)
Pole contact composition3 NO
Protective coverWith
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Auxiliary contact composition1 NO + 1 NC
[Ui] rated insulation voltagePower circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947
Overvoltage categoryIII
[Ith] conventional free air thermal current60 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuit
Irms rated making capacity800 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1
Time constant65 ms
Control circuit typeDC wide range
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.1…0.3 Uc (-40…70 °C):drop-out DC
0.7…1.25 Uc (-40…50 °C):operational DC
1…1.25 Uc (50…70 °C):operational DC
Average impedance1.5 mOhm – Ith 60 A 50 Hz for power circuit
Power dissipation per pole5.4 W AC-1
2.4 W AC-3
2.4 W AC-3e
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Operating time20…35 ms opening
85…110 ms closing
Maximum operating rate3600 cyc/h 60 °C
Inrush power in W22 W (at 20 °C)
Hold-in power consumption in W22 W at 20 °C
Insulation resistance> 10 MOhm for signalling circuit
Connections – terminalsControl circuit: lugs-ring terminals – external diameter: 8 mm
Power circuit: lugs-ring terminals – external diameter: 13 mm
Tightening torqueControl circuit: 1.7 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm M3.5
Control circuit: 1.7 N.m – on lugs-ring terminals – with screwdriver Philips No 2 M3.5
Power circuit: 2.5 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm M5
Power circuit: 2.5 N.m – on lugs-ring terminals – with screwdriver Philips No 2 M5
Mounting supportRail
Plate
Electrical durability1.4 Mcycles 60 A AC-1 at Ue <= 440 V
1.5 Mcycles 40 A AC-3 at Ue <= 440 V
1.5 Mcycles 40 A AC-3e at Ue <= 440 V
Mechanical durability20 Mcycles
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating altitude0…3000 m
Compatibility codeLC1D
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
EN 45545: R22 HL3
EN 45545: R26 HL3
DIN 5510-2
Product certificationsIEC
CCC
UKCA
Environment
Climatic withstandconforming to IACS E10
conforming to IEC 60947-1 Annex Q category D
Ambient air temperature for storage-60…80 °C
Fire resistance850 °C conforming to IEC 60695-2-1
Height127 mm
Width75 mm
Depth176 mm
Net weight2.185 kg
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor open (8 Gn for 11 ms)
Shocks contactor closed (10 Gn for 11 ms)
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height18.9 cm
Package 1 Width10.2 cm
Package 1 Length12.9 cm
Package 1 Weight2.4 kg
Logistical informations
Country of originCZ
Contractual warranty
Warranty (in months)18

Customer Reviews