LC1D800046FWS207 | CONT 4P AC1 125A COIL 110VCC RAIL - Schneider Electric
LC1D800046FWS207 | CONT 4P AC1 125A COIL 110VCC RAIL - Schneider Electric Original price was: $610.68.Current price is: $274.80. Excl. GST
Back to products
LC1D80004G7 | TeSys D 4P AC1 440V 125A 120VAC COIL - Schneider Electric
LC1D80004G7 | TeSys D 4P AC1 440V 125A 120VAC COIL - Schneider Electric Original price was: $741.07.Current price is: $333.48. Excl. GST

LC1D80004F7 | Contactor TeSys Deca 125A 4P 110V AC – Schneider Electric

SKU: LC1D80004F7

Original price was: $837.92.Current price is: $377.06. Excl. GST

Dispatch By : 7 Weeks

Dispatch By : 7 Weeks

11 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit: <= 300 V DC 25…400 Hz
Power circuit: <= 690 V AC
[Ie] rated operational current125 A (at <60 °C) at <= 1000 V AC AC-1 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
55 A (at <60 °C) at <= 400 V AC AC-4 for power circuit
[Uc] control circuit voltage110 V AC 50/60 Hz
Complementary
Motor power kW22 kW at 220/230 V AC 50/60 Hz (AC-3)
37 kW at 380/400 V AC 50/60 Hz (AC-3)
45 kW at 415/440 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 660/690 V AC 50/60 Hz (AC-3)
Compatibility codeLC1D
Pole contact composition4 NO
Protective coverWith
[Ith] conventional free air thermal current125 A (at 60 °C) for power circuit
Irms rated making capacity1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current640 A 40 °C – 10 s for power circuit
990 A 40 °C – 1 s for power circuit
135 A 40 °C – 10 min for power circuit
320 A 40 °C – 1 min for power circuit
Associated fuse rating200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance0.8 mOhm – Ith 125 A 50 Hz for power circuit
Power dissipation per pole12.5 W AC-1
[Ui] rated insulation voltagePower circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability4 Mcycles
Electrical durability0.8 Mcycles 125 A AC-1 at Ue <= 440 V
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.85…1.1 Uc (-40…55 °C):operational AC 60 Hz
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…55 °C):operational AC 50 Hz
1…1.1 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA245 VA 60 Hz cos phi 0.75 (at 20 °C)
245 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA26 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation6…10 W at 50/60 Hz
Operating time20…35 ms closing
6…20 ms opening
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: flexible without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible with cable end
Power circuit: connector 2 4…16 mm² – cable stiffness: flexible with cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: solid without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 12 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Mounting supportPlate
Rail
Environment
StandardsEN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2
Product certificationsCCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Shocks contactor open (8 Gn for 11 ms)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Height127 mm
Width96 mm
Depth125 mm
Net weight1.76 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.400 cm
Package 1 Width10.700 cm
Package 1 Length13.500 cm
Package 1 Weight1.688 kg
Unit Type of Package 2S02
Number of Units in Package 25
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.730 kg