LC1DT80AKUE | TeSysCTR4P80A AC3NO+NC100-250V ACDC EVLK - Schneider Electric
LC1DT80AKUE | TeSysCTR4P80A AC3NO+NC100-250V ACDC EVLK - Schneider Electric Original price was: R$2,896.56.Current price is: R$1,303.45. Excl. GST
Back to products
LC1DT80AU7 | TeSys 4 POLE EVLK CTR AC1 415V 80 A - Schneider Electric
LC1DT80AU7 | TeSys 4 POLE EVLK CTR AC1 415V 80 A - Schneider Electric Original price was: R$3,612.68.Current price is: R$1,625.70. Excl. GST

LC1DT80AP7 | TeSys 4 POLE EVLK CTR AC1 415V 80 A – Schneider Electric

SKU: LC1DT80AP7

Original price was: R$3,535.29.Current price is: R$1,590.88. Excl. GST

Dispatch By : 1 Weeks

Dispatch By : 1 Weeks

17 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Specifications

Main
RangeTeSys
TeSys Deca
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage230 V AC 50/60 Hz
Complementary
Compatibility codeLC1D
Pole contact composition4 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit
80 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1000 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current640 A 40 °C – 10 s for power circuit
900 A 40 °C – 1 s for power circuit
110 A 40 °C – 10 min for power circuit
260 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
Average impedance1.6 mOhm – Ith 80 A 50 Hz for power circuit
Power dissipation per pole10.2 W AC-1
[Ui] rated insulation voltagePower circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Electrical durability1.4 Mcycles 80 A AC-1 at Ue <= 440 V
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation4…5 W at 50/60 Hz
Operating time4…19 ms opening
12…26 ms closing
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: solid without cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 8 N.m – on screw clamp terminals – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on screw clamp terminals – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting supportRail
Plate
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1
Product certificationsDNV
GL
UL
CSA
BV
GOST
CCC
LROS (Lloyds register of shipping)
RINA
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Height122 mm
Width70 mm
Depth120 mm
Net weight1.15 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.100 cm
Package 1 Width13.700 cm
Package 1 Length15.300 cm
Package 1 Weight1.094 kg
Unit Type of Package 2S02
Number of Units in Package 27
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.132 kg
Contractual warranty
Warranty (in months)18